Biomechanical investigation of a minimally invasive posterior spine stabilization system in comparison to the Universal Spinal System (USS)

被引:20
|
作者
Kubosch, D. [1 ]
Kubosch, E. J. [1 ]
Gueorguiev, B. [2 ]
Zderic, I. [2 ]
Windolf, M. [2 ]
Izadpanah, K. [1 ]
Suedkamp, N. P. [1 ]
Strohm, P. C. [1 ]
机构
[1] Univ Freiburg Med Ctr, Dept Orthopaed & Trauma Surg, Hugstetterstr 55, D-79106 Freiburg, Germany
[2] AO Res Inst Davos, Clavadelerstr 8, CH-7270 Davos, Switzerland
来源
BMC MUSCULOSKELETAL DISORDERS | 2016年 / 17卷
关键词
Fracture; Biomechanic; Minimally invasive surgery; Percutaneous fixation; Pedicle screw; Polyaxial; LUMBAR SPINE; BURST FRACTURES; PEDICLE SCREWS; FUSION; THORACOLUMBAR; INJURIES; FIXATION; EFFICACY; LOAD;
D O I
10.1186/s12891-016-0983-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although minimally invasive posterior spine implant systems have been introduced, clinical studies reported on reduced quality of spinal column realignment due to correction loss. The aim of this study was to compare biomechanically two minimally invasive spine stabilization systems versus the Universal Spine Stabilization system (USS). Methods: Three groups with 5 specimens each and 2 foam bars per specimen were instrumented with USS (Group 1) or a minimally invasive posterior spine stabilization system with either polyaxial (Group 2) or monoaxial (Group 3) screws. Mechanical testing was performed under quasi-static ramp loading in axial compression and torsion, followed by destructive cyclic loading run under axial compression at constant amplitude and then with progressively increasing amplitude until construct failure. Bending construct stiffness, torsional stiffness and cycles to failure were investigated. Results: Initial bending stiffness was highest in Group 3, followed by Group 2 and Group 1, without any significant differences between the groups. A significant increase in bending stiffness after 20'000 cycles was observed in Group 1 (p = 0.002) and Group 2 (p = 0.001), but not in Group 3, though the secondary bending stiffness showed no significant differences between the groups. Initial and secondary torsional stiffness was highest in Group 1, followed by Group 3 and Group 2, with significant differences between all groups (p = 0.047). A significant increase in initial torsional stiffness after 20' 000 cycles was observed in Group 2 (p = 0.017) and 3 (p = 0.013), but not in Group 1. The highest number of cycles to failure was detected in Group 1, followed by Group 3 and Group 2. This parameter was significantly different between Group 1 and Group 2 (p = 0.001), between Group 2 and Group 3 (p = 0.002), but not between Group 1 and Group 3. Conclusions: These findings quantify the correction loss for minimally invasive spine implant systems and imply that unstable spine fractures might benefit from stabilization with conventional implants like the USS.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Assessment of Clinical Decision Support System Efficiency in Spinal Neurosurgery for Personalized Minimally Invasive Technologies Used on Lumbar Spine
    Byvaltsev, V. A.
    Kalinin, A. A.
    SOVREMENNYE TEHNOLOGII V MEDICINE, 2021, 13 (05) : 13 - 21
  • [32] A Flexible Ultrasound Scanning System for Minimally Invasive Spinal Surgery Navigation
    Zhang, Jingyu
    Wang, Yunjiang
    Liu, Tianjian
    Yang, Keji
    Jin, Haoran
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2021, 3 (02): : 426 - 435
  • [33] Augmented Reality-based Navigation System for Minimally Invasive Spine Surgery
    Wang Q.
    Zhao K.
    Song G.
    Zhao Y.
    Zhao X.
    Jiqiren/Robot, 2023, 45 (05): : 546 - 553
  • [34] Erratum to: Universal multifunctional HD video system for minimally invasive, open and microsurgery
    Nicholas N. Nissen
    Vijay G. Menon
    Steven D. Colquhoun
    James Williams
    George Berci
    Surgical Endoscopy, 2013, 27 (3) : 788 - 788
  • [35] Impairment-driven cancer rehabilitation in patients with neoplastic spinal cord compression using minimally invasive spine stabilization
    Yukako Ishida
    Hideki Shigematsu
    Shinji Tsukamoto
    Yasuhiko Morimoto
    Eiichiro Iwata
    Akinori Okuda
    Sachiko Kawasaki
    Masato Tanaka
    Hiromasa Fujii
    Yasuhito Tanaka
    Akira Kido
    World Journal of Surgical Oncology, 18
  • [36] Impairment-driven cancer rehabilitation in patients with neoplastic spinal cord compression using minimally invasive spine stabilization
    Ishida, Yukako
    Shigematsu, Hideki
    Tsukamoto, Shinji
    Morimoto, Yasuhiko
    Iwata, Eiichiro
    Okuda, Akinori
    Kawasaki, Sachiko
    Tanaka, Masato
    Fujii, Hiromasa
    Tanaka, Yasuhito
    Kido, Akira
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2020, 18 (01)
  • [37] A Comparison of Different Minimally Invasive and Open Posterior Spinal Procedures Using Volumetric Measurements of the Surgical Exposures
    Regev, Gilad J.
    Kim, Choll W.
    Salame, Khalil
    Behrbalk, Eyal
    Keynan, Ory
    Lador, Ran
    Mangel, Laurence
    Lidar, Zvi
    CLINICAL SPINE SURGERY, 2017, 30 (09): : 425 - 428
  • [38] Cotrel-Dubousset (CD) or Universal Spine System (USS) instrumentation in adolescent idiopathic scoliosis (AIS) -: Comparison of midterm clinical, functional, and radiologic outcomes
    Remes, V
    Helenius, I
    Schlenzka, D
    Yrjönen, T
    Ylikoski, M
    Poussa, M
    SPINE, 2004, 29 (18) : 2024 - 2030
  • [39] Comparison of the modified Wiltse's approach with spinal minimally invasive system and traditional approach for the therapy of thoracolumbar fracture
    Chang, Jie
    Cao, Jiang
    Huang, Ziyan
    Wang, Boyao
    Sui, Tao
    Cao, Xiaojian
    JOURNAL OF BIOMEDICAL RESEARCH, 2020, 34 (05): : 379 - 386
  • [40] Comparison of the modified Wiltse's approach with spinal minimally invasive system and traditional approach for the therapy of thoracolumbar fracture
    Jie Chang
    Jiang Cao
    Ziyan Huang
    Boyao Wang
    Tao Sui
    Xiaojian Cao
    The Journal of Biomedical Research, 2020, 34 (05) : 379 - 386