OPTICAL PARAMETRIC AMPLIFICATION BY INCOHERENT CONICAL PUMP BEAM

被引:0
|
作者
Tamuliene, V. [1 ]
Smilgevicius, V. [1 ]
Kudarauskas, D. [1 ]
Butkus, R. [1 ]
Stabinis, A. [1 ]
Piskarskas, A. [1 ]
机构
[1] Vilnius Univ, Dept Quantum Elect, Sauletekio 10, LT-10223 Vilnius, Lithuania
来源
LITHUANIAN JOURNAL OF PHYSICS | 2017年 / 57卷 / 01期
关键词
optical parametric amplification; conical beams; incoherence; LIGHT;
D O I
10.3952/physics.v57i1.3452
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Optical parametric amplification of an input narrowband signal beam in the field of a spatially incoherent conical pump is investigated. Two amplification regimes - onset and exponential - are distinguished. The possibility to amplify the signal beam significantly and obtain a smooth intensity profile at the output is revealed. It is shown that the incoherent conical beam may act on the signal beam as a plane wave. Good agreement of theoretical and experimental data is obtained.
引用
收藏
页码:19 / 28
页数:10
相关论文
共 50 条
  • [41] Pump-noise transfer in optical parametric chirped-pulse amplification
    Forget, N
    Cotel, A
    Brambrink, E
    Audebert, P
    Le Blanc, C
    Jullien, A
    Albert, O
    Chériaux, G
    OPTICS LETTERS, 2005, 30 (21) : 2921 - 2923
  • [42] Generation of accurately synchronized pump source for optical parametric chirped pulse amplification
    H. Zeng
    J. Wu
    H. Xu
    K. Wu
    E Wu
    Applied Physics B, 2004, 79 : 837 - 839
  • [43] Optical parametric oscillator incoherent spectroscopy
    Yanagawa, T
    Naganuma, K
    Kanbara, H
    Kaino, T
    OPTICS LETTERS, 1996, 21 (05) : 318 - 320
  • [44] Optical parametric oscillator incoherent spectroscopy
    NTT Opto-electronics Laboratories, 3-1 Morinosato Wakamiya, Kanagawa Prefecture 243-01, Japan
    Opt. Lett., 5 (318-320):
  • [45] Scanning broadband optical parametric chirped pulse amplification based on optical beam deflection
    Ye Rong
    Zhong Zhe-Qiang
    Wu Xian-Yun
    ACTA PHYSICA SINICA, 2019, 68 (02)
  • [46] OPTICAL PARAMETRIC OSCILLATOR DEPENDENCE ON PUMP LASER-BEAM QUALITY
    EWANIZKY, TF
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1978, 14 (12) : 962 - 966
  • [47] Amplification of ultrashort optical pulses in a two-pump fiber optical parametric chirped pulse amplifier
    d'Augeres, Patrick Beaure
    Hugonnot, Emmanuel
    Stroiazzo, Lea
    Kudlinski, Alexandre
    Mussot, Arnaud
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2013,
  • [48] Experimental investigation of pulse generation with one-pump fiber optical parametric amplification
    Vedadi, Armand A.
    Shoaie, Mohammad Amin
    Bres, Camille-Sophie
    OPTICS EXPRESS, 2012, 20 (24): : 27344 - 27354
  • [49] Contrast limitation due to pump noise in an optical parametric chirped pulse amplification system
    Ross, I. N.
    New, G. H. C.
    Bates, P. K.
    OPTICS COMMUNICATIONS, 2007, 273 (02) : 510 - 514
  • [50] Research of two-pump optical parametric amplification using photonic crystal fiber
    State Key Laboratory of Transient Optics and Photonics Technology, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710068, China
    不详
    不详
    Guangzi Xuebao, 2006, 8 (1137-1141):