A new universal laryngoscope blade:: a preliminary comparison with Macintosh laryngoscope blades

被引:11
|
作者
Gerlach, K
Wenzel, V
von Knobelsdorff, G
Steinfath, M
Dörges, V
机构
[1] Univ Hosp Kiel, Dept Anaesthesiol & Intens Care Med, D-24105 Kiel, Germany
[2] Univ Hosp Lubeck, Dept Anaesthesiol, Lubeck, Germany
[3] Leopold Franzens Univ, Dept Anesthesiol & Crit Care Med, Innsbruck, Austria
[4] St Bernward Hosp, Dept Anaesthesia & Intens Care Med, Hildesheim, Germany
关键词
airway management; intubation; laryngoscope blades; macintosh; orotracheal intubation;
D O I
10.1016/S0300-9572(02)00434-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The Dorges universal laryngoscope blade has several features designed to facilitate tracheal intubation. The number of laryngoscope blades may be reduced from four to two, or even one, which indicate less space requirement and costs. This new universal laryngoscope blade, has a lower profile (height 15 vs. 22 mm) than a Macintosh laryngoscope blade size 3 and 4, which may facilitate manoeuvring of the laryngoscope in the mouth. In random order, 40 non-anaesthesia senior house officers used a Macintosh laryngoscope blade size 3 or 4 in an adult airway management trainer, a Macintosh laryngoscope blade size 2 in a paediatric airway management trainer, and the Dorges universal laryngoscope blade for both airway management trainers to perform orotracheal intubation. The number of intubation attempts and failures was counted. Participants reported the laryngoscopic view according to Cormack and Lehane. The time from touching the laryngoscope to the first adequate lung insufflation was measured, and subjective assessment regarding handling of both blades was recorded. Number of intubation failures, the laryngoscopic view according to Cormack and Lehane, and subjective assessment was comparable between groups. Orotracheal intubation of the adult airway management trainer with the Dorges universal laryngoscope blade took significantly less time compared to the Macintosh laryngoscope blades (14 (7-57) vs. 20 (8-43) s; P <0.001); all other intubating times were comparable. In conclusion, in this model, the Dorges universal laryngoscope blade was comparable to the Macintosh laryngoscope blades size 2-4, and may save time, cost and space. (C) 2003 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:63 / 67
页数:5
相关论文
共 50 条
  • [31] Comparison of Disposcope endoscope with Macintosh laryngoscope for laryngoscopy
    Ziyu Gu
    Liang Zhu
    Zhouquan Wu
    Anesthesiology and Perioperative Science, 1 (4):
  • [32] Laryngoscope blades
    Macintosh, RR
    LANCET, 1944, 1 : 485 - 485
  • [33] Inventor of the Macintosh laryngoscope
    Scott, J.
    ANAESTHESIA AND INTENSIVE CARE, 2009, 37 (04) : 673 - 673
  • [34] Comparison of the Flexiblade levering laryngoscope with the English Macintosh laryngoscope in patients with a poor laryngoscopic view
    Beilin, B
    Yardeni, IZ
    Smolyarenko, V
    Zeidel, A
    Ram, E
    Mayburd, E
    ANAESTHESIA, 2005, 60 (04) : 400 - 405
  • [35] A comparison of the McGrath® video-laryngoscope and the Macintosh laryngoscope in patients with cervical spine immobilisation
    Shippey, B.
    McGuire, B.
    Dalton, A.
    ANAESTHESIA, 2013, 68 (08) : 883 - 883
  • [36] A comparison of the ease of tracheal intubation using a McGrath MAC® laryngoscope and a standard Macintosh laryngoscope
    Wallace, C. D.
    Foulds, L. T.
    McLeod, G. A.
    Younger, R. A.
    McGuire, B. E.
    ANAESTHESIA, 2015, 70 (11) : 1281 - 1285
  • [37] AN ANALYSIS OF LARYNGOSCOPE BLADE SHAPE AND DESIGN - NEW CRITERIA FOR LARYNGOSCOPE EVALUATION
    MARKS, RRD
    HANCOCK, R
    CHARTERS, P
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (03): : 262 - 270
  • [38] Comparison of grooved and conventional Macintosh laryngoscope blades for throat pack insertion: A randomized control trial
    John, Jyothi Elizabeth
    Nileshwar, Anitha
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2024, 40 (03) : 498 - 503
  • [39] A comparison of the Macintosh laryngoscope, McGrath video laryngoscope, and Pentax Airway Scope in paediatric nasotracheal intubation
    Ji Young Yoo
    Yun Jeong Chae
    Young Bok Lee
    Sujin Kim
    Jaemoon Lee
    Dae Hee Kim
    Scientific Reports, 8
  • [40] Comparison of the McGrath video laryngoscope and macintosh direct laryngoscope in obstetric patients: A randomized controlled trial
    Toker, Melike Korkmaz
    Altiparmak, Basak
    Karabay, Ayse Gul