Finite element analysis modeling of plates versus intramedullary nails in closed comminuted midshaft tibial fractures

被引:2
|
作者
El-Desouky, Mahmoud Ahmed [1 ]
Saleh, Ayman Ali [2 ]
Amr, Sherif Mamdouh [1 ]
Barakat, Ahmed Samir [1 ]
机构
[1] Cairo Univ, Fac Med, Dept Orthoped Surg & Traumatol, Cairo 11562, Egypt
[2] Aseer Cent Hosp, Dept Orthoped Surg & Traumatol, Abha 62523, Saudi Arabia
来源
SICOT-J | 2022年 / 8卷
关键词
Tibial fracture; Interlocking nail; Locking plate; Finite element analysis; EXTERNAL FIXATION; EPIDEMIOLOGY;
D O I
10.1051/sicotj/2022025
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Tibial shaft fractures are usually treated by interlocking nails or plates. The ideal implant choice depends on many variables. Aim: To assess the mechanical behavior of interlocking nails and plates in the treatment of closed comminuted midshaft fractures of the tibia using finite element analysis. Material and methods: This is a prospective study of 50 patients with a mean age of 28.4 years with closed comminuted fractures of the midshaft of the tibia. Data evaluation was done by Finite element analysis (FEA). Fixation was revised in two cases. Results: After load application, there were significant differences in both bending (P = 0.041) and strain percent (P = 0.017), reflecting that interlocking nails were superior to plates. There were also significant differences between titanium and stainless-steel materials in bending (p = 0.041) and strain percent (p = 0.017) after applying load, indicating that titanium was superior to stainless steel. Conclusion: Interlocking nails are superior to plates in treating midshaft tibial fractures. The use of blocking screws may be needed in interlocking nails depending on the pattern and extension of the fracture.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Single versus dual elastic nails for closed reduction and antegrade intramedullary nailing of displaced fifth metacarpal neck fractures
    Langqing Zeng
    Lulu Zeng
    Xiaogang Miao
    Yunfeng Chen
    Weiguo Liang
    Yuwen Jiang
    Scientific Reports, 11
  • [32] Quadruple Versus Double Flexible Intramedullary Nails to Treat Pediatric Distal-third Tibial Shaft Fractures: A Biomechanical Comparison
    Zubair, Adnan
    Samuelson, Eric M.
    Morris, Randal P.
    Foreman, Mark
    Gagnon-Bartsch, Johann A.
    Rosenfeld, Scott B.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2020, 40 (09) : 487 - 491
  • [33] Meta-analysis of reamed versus unreamed intramedullary nailing for open tibial fractures
    Shao, Yinchu
    Zou, Hongxing
    Chen, Shaobo
    Shan, Jichun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9
  • [34] Intramedullary nail versus plate treatments for distal tibial fractures: A meta-analysis
    Yu, Jiwen
    Li, Leiming
    Wang, Tong
    Sheng, Luxin
    Huo, Yongfeng
    Yin, Zhaoyang
    Gu, Guangxue
    He, Weidong
    INTERNATIONAL JOURNAL OF SURGERY, 2015, 16 : 60 - 68
  • [35] Meta-analysis of reamed versus unreamed intramedullary nailing for open tibial fractures
    Yinchu Shao
    Hongxing Zou
    Shaobo Chen
    Jichun Shan
    Journal of Orthopaedic Surgery and Research, 9
  • [36] Biomechanics and finite element analysis comparing posterior T-plates with LCP for fixation of posterolateral tibial plate fractures
    Hu, Zhenghui
    Ren, Weizhi
    Peng, Jian
    Gu, Zenghui
    Wu, Chenying
    Wu, Weicheng
    Zhang, Wen
    Xu, Wei
    Li, Liubing
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [37] Effect of minimally invasive percutaneous plates versus interlocking intramedullary nailing in tibial shaft treatment for fractures in adults: A meta-analysis
    He, Guo-Chao
    Wang, Hua-Song
    Wang, Qing-Fu
    Chen, Zhuang-Hong
    Cai, Xian-Hua
    CLINICS, 2014, 69 (04) : 234 - 240
  • [38] Parametric Finite Element Analysis of Intramedullary Nail Fixation of Proximal Femur Fractures
    Tucker, Scott M.
    Wee, Hwabok
    Fox, Edward
    Reid, J. Spence
    Lewis, Gregory S.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2019, 37 (11) : 2358 - 2366
  • [39] Finite element analysis of spiral plate and Herbert screw fixation for treatment of midshaft clavicle fractures
    Zhang, Xiaojuan
    Cheng, Xiaodong
    Yin, Bing
    Wang, Jianzhao
    Li, Sheng
    Liu, Guobin
    Hu, Zusheng
    Wu, Weiwei
    Zhang, Yingze
    MEDICINE, 2019, 98 (34)
  • [40] Plate fixation versus intramedullary fixation for midshaft clavicle fractures: Meta-analysis of complications and functional outcomes
    Xiao, Hao
    Gao, Hengbo
    Zheng, Tuokang
    Zhao, Jianhui
    Tian, Yingping
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2016, 44 (02) : 201 - 215