Real-Time Artifact Removal System for Surface EMG Processing During Ten-Fold Frequency Electrical Stimulation

被引:7
|
作者
Wang, Hai-Peng [1 ,2 ]
Bi, Zheng-Yang [3 ]
Fan, Wen-Jie [2 ]
Zhou, Yi-Xin [2 ]
Zhou, Yu-Xuan [3 ,4 ]
Li, Fei [2 ]
Wang, Keping [2 ]
Lu, Xiao-Ying [3 ,5 ]
Wang, Zhi-Gong [2 ,5 ]
机构
[1] Sanjiang Univ, Sch Elect & Informat Engn, Nanjing 210012, Peoples R China
[2] Southeast Univ, Inst RF & OE ICs, Nanjing 210096, Peoples R China
[3] Southeast Univ, State Key Lab Bioelect, Nanjing 210096, Peoples R China
[4] Nanjing Med Univ, Sch Biomed Engn & Informat, Dept Biomed Engn, Nanjing 211166, Peoples R China
[5] Nantong Univ, Coinnovat Ctr Neuroregenerat, Nantong 226001, Peoples R China
来源
IEEE ACCESS | 2021年 / 9卷
基金
中国国家自然科学基金;
关键词
Electromyography; Iron; Real-time systems; Noise reduction; Filtering algorithms; Blanking; Field programmable gate arrays; Functional electrical stimulation (FES); stimulus artifact removal (SAR); surface electromyography (sEMG); adaptive filter; field-programmable gate array (FPGA); SIGNAL; DEVICE;
D O I
10.1109/ACCESS.2021.3077644
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, three easily implemented hardware algorithms, including the adaptive prediction error filter based on the Gram-Schmidt algorithm (GS-APEF), the least mean square adaptive filter and the comb filter, are extensively investigated for artifact denoising on a constructed semi-simulated database with varied ten-fold frequency stimulation. By implementing the GS-APEF in the field-programmable gate array (FPGA) and using the edge noise mitigating technique, a stimulation artifact denoising system is designed to realize real-time stimulation artifact removal under varied ten-fold frequency functional electrical stimulation. Good performance of the artifact denoising is demonstrated in proof-of-concept experiments on able-bodied subjects with a mean correlation coefficient between the root mean square profile of denoised surface electromyography and volitional force of 0.94, verifying the validity of the proposed prototype.
引用
收藏
页码:68320 / 68331
页数:12
相关论文
共 50 条
  • [1] Real-Time Artifact Removal System for Surface EMG Processing during Ten-Fold Frequency Electrical Stimulation
    Wang, Hai-Peng
    Bi, Zheng-Yang
    Fan, Wen-Jie
    Zhou, Yi-Xin
    Zhou, Yu-Xuan
    Li, Fei
    Wang, Keping
    Lu, Xiao-Ying
    Wang, Zhi-Gong
    IEEE Access, 2021, 9 : 68320 - 68331
  • [2] Hardware System for Real-Time EMG Signal Acquisition and Separation Processing during Electrical Stimulation
    Hsueh, Ya-Hsin
    Yin, Chieh
    Chen, Yan-Hong
    JOURNAL OF MEDICAL SYSTEMS, 2015, 39 (09)
  • [3] Hardware System for Real-Time EMG Signal Acquisition and Separation Processing during Electrical Stimulation
    Ya-Hsin Hsueh
    Chieh Yin
    Yan-Hong Chen
    Journal of Medical Systems, 2015, 39
  • [4] A Blink Restoration System With Contralateral EMG Triggered Stimulation and Real-Time Artifact Blanking
    Yi, Xin
    Jia, Jun
    Deng, Simin
    Shen, Steve Guofang
    Xie, Qing
    Wang, Guoxing
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2013, 7 (02) : 140 - 148
  • [5] A System for Real-Time Estimation of Joint Torque with Evoked EMG under Electrical Stimulation
    Li, Zhan
    Hayashibe, Mitsuhiro
    Andreu, David
    Guiraud, David
    REPLACE, REPAIR, RESTORE, RELIEVE - BRIDGING CLINICAL AND ENGINEERING SOLUTIONS IN NEUROREHABILITATION, 2014, 7 : 513 - 520
  • [6] A Real-time EMG-controlled Functional Electrical Stimulation System for Mirror Therapy
    Chen, Yuyang
    Dai, Chenyun
    Chen, Wei
    2019 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS 2019), 2019,
  • [7] A Blink Restoration System with Contralateral EMG Triggered Stimulation and Real-Time Software Based Artifact Blanking
    Jia, Jun
    Yi, Xin
    Wang, Mengde
    Wang, Guoxing
    Deng, Simin
    Shen, Guofang
    2012 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 2012), 2012, : 1536 - 1539
  • [8] Accurate real-time feedback of surface EMG during fMRI
    Ganesh, G.
    Franklin, D. W.
    Gassert, R.
    Imamizu, H.
    Kawato, M.
    JOURNAL OF NEUROPHYSIOLOGY, 2007, 97 (01) : 912 - 920
  • [9] A Stimulus Artifact Removal Technique for SEMG Signal Processing During Functional Electrical Stimulation
    Qiu, Shuang
    Feng, Jing
    Xu, Rui
    Xu, Jiapeng
    Wang, Kun
    He, Feng
    Qi, Hongzhi
    Zhao, Xin
    Zhou, Peng
    Zhang, Lixin
    Ming, Dong
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (08) : 1959 - 1968
  • [10] Automatic ECG artifact removal in the real-time SEMG recording system
    Hu, Yong
    Kwok, Jerry
    Tse, Jessica
    2013 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND VIRTUAL ENVIRONMENTS FOR MEASUREMENT SYSTEMS AND APPLICATIONS (CIVEMSA), 2013, : 72 - 77