A Blink Restoration System With Contralateral EMG Triggered Stimulation and Real-Time Artifact Blanking

被引:34
|
作者
Yi, Xin [1 ]
Jia, Jun [1 ]
Deng, Simin [2 ]
Shen, Steve Guofang [3 ]
Xie, Qing [4 ]
Wang, Guoxing [1 ,5 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Microelect, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Shanghai 200025, Peoples R China
[3] Shanghai Ninth Peoples Hosp, Dept Oral & Maxillofacial Surg, Shanghai 200011, Peoples R China
[4] Shanghai Jiao Tong Univ, Rehabil Dept, Rui Jin Hosp, Shanghai 200025, Peoples R China
[5] Chinese Acad Sci, Shanghai Adv Res Inst, Ctr CMOS Imager, Shanghai 200240, Peoples R China
关键词
Blanking; digital filter; functional-electrical stimulation (FES); stimulus artifact; STIMULUS ARTIFACT; ELECTRICAL-STIMULATION; ORBICULARIS OCULI; GOLD WEIGHT; REMOVAL; SIGNALS; NERVE; EXTRACTION; SUPPRESSOR; ELECTRODES;
D O I
10.1109/TBCAS.2013.2255051
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patients suffering from facial paralysis are on the hazard of disfigurement and loss of vision due to loss of blink function. Functional-electrical stimulation (FES) is one possible way of restoring blink and other functions in these patients. A blink restoration system for uni-lateral facial paralyzed patients is described in this paper. The system achieves restoration of synchronized blink through processing the myoelectric signal of orbicularis oculi at the normal side in real-time as the trigger to stimulate the paralyzed eyelid. Design issues are discussed, including EMG processing, stimulating strategies and real-time artifact blanking. Two artifact removal approaches based on sample and hold and digital filtering technique are proposed and implemented. Finally, the whole system has been verified on rabbit models.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 50 条
  • [1] A Blink Restoration System with Contralateral EMG Triggered Stimulation and Real-Time Software Based Artifact Blanking
    Jia, Jun
    Yi, Xin
    Wang, Mengde
    Wang, Guoxing
    Deng, Simin
    Shen, Guofang
    2012 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 2012), 2012, : 1536 - 1539
  • [2] Real-Time Artifact Removal System for Surface EMG Processing during Ten-Fold Frequency Electrical Stimulation
    Wang, Hai-Peng
    Bi, Zheng-Yang
    Fan, Wen-Jie
    Zhou, Yi-Xin
    Zhou, Yu-Xuan
    Li, Fei
    Wang, Keping
    Lu, Xiao-Ying
    Wang, Zhi-Gong
    IEEE Access, 2021, 9 : 68320 - 68331
  • [3] Real-Time Artifact Removal System for Surface EMG Processing During Ten-Fold Frequency Electrical Stimulation
    Wang, Hai-Peng
    Bi, Zheng-Yang
    Fan, Wen-Jie
    Zhou, Yi-Xin
    Zhou, Yu-Xuan
    Li, Fei
    Wang, Keping
    Lu, Xiao-Ying
    Wang, Zhi-Gong
    IEEE ACCESS, 2021, 9 : 68320 - 68331
  • [4] A REAL-TIME PROCESSING FLOW FOR ICA BASED EEG ACQUISITION SYSTEM WITH EYE BLINK ARTIFACT ELIMINATION
    Huang, Kuan-Ju
    Liao, Jui-Chieh
    Shih, Wei-Yeh
    Feng, Chih-Wei
    Chang, Jui-Chung
    Chou, Chia-Ching
    Fang, Wai-Chi
    2013 IEEE WORKSHOP ON SIGNAL PROCESSING SYSTEMS (SIPS), 2013, : 237 - 240
  • [5] Real-time blocking artifact reduction system based on spatially adaptive image restoration
    Lee, JS
    Choe, YS
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XXI, 1998, 3460 : 577 - 586
  • [6] An unsupervised eye blink artifact detection method for real-time electroencephalogram processing
    Chang, Won-Du
    Lim, Jeong-Hwan
    Im, Chang-Hwan
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (03) : 401 - 417
  • [7] A System for Real-Time Estimation of Joint Torque with Evoked EMG under Electrical Stimulation
    Li, Zhan
    Hayashibe, Mitsuhiro
    Andreu, David
    Guiraud, David
    REPLACE, REPAIR, RESTORE, RELIEVE - BRIDGING CLINICAL AND ENGINEERING SOLUTIONS IN NEUROREHABILITATION, 2014, 7 : 513 - 520
  • [8] A Real-time EMG-controlled Functional Electrical Stimulation System for Mirror Therapy
    Chen, Yuyang
    Dai, Chenyun
    Chen, Wei
    2019 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS 2019), 2019,
  • [9] Compact electrotactile stimulation and EMG acquisition system with embedded blanking of stimulation artifacts
    Strbac, Matija
    Isakovic, Milica
    Malesevic, Jovana
    Keller, Thiery
    Ilic, Vojin
    Jorgovanovic, Nikola
    Dosen, Strahinja
    2019 26TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS (ICECS), 2019, : 863 - 866
  • [10] Real-Time Removal of Stimulus Artifact for Closed-Loop Deep Brain Stimulation by Synchronized Sample-And-Hold Artifact Blanking (SSAB): Verification in Animal Model
    Wu, Y. H.
    Lin, H. C.
    Huang, C. W.
    Hsieh, C. C.
    Ker, M. D.
    MOVEMENT DISORDERS, 2024, 39 : S811 - S811