Fluorochrome choices for multi-color flow cytometry

被引:35
|
作者
Flores-Montero, Juan [1 ,2 ,3 ]
Kalina, Tomas [4 ]
Corral-Mateos, Alba [1 ,2 ,3 ]
Sanoja-Flores, Luzalba [1 ,2 ,3 ]
Perez-Andres, Martin [1 ,2 ,3 ]
Martin-Ayuso, Marta [5 ]
Sedek, Lukasz [6 ]
Rejlova, Katerina [4 ]
Mayado, Andrea [1 ,2 ,3 ]
Fernandez, Paula [7 ]
van der Velden, Vincent [8 ]
Bottcher, Sebastian [9 ]
van Dongen, Jaques J. M. [10 ]
Orfao, Alberto [1 ,2 ,3 ]
机构
[1] Univ Salamanca, Cytometry Serv Nucleus, Canc Res Ctr IBMCC CSIC USAL IBSAL, Madrid, Spain
[2] Univ Salamanca, Dept Med, Madrid, Spain
[3] Inst Salud Carlos III, Ctr Invest Biomed Red Canc CIBER ONC, CB16-1 2-00400, Madrid, Spain
[4] Charles Univ Prague, Fac Med 2, Dept Pediat Hematol & Oncol, CLIP Cytometry, Prague, Czech Republic
[5] Cytognos SL, Salamanca, Spain
[6] Med Univ Silesia, Dept Pediat Hematol & Oncol, Zabrze, Poland
[7] Kantonsspital Aarau AG, Inst Lab Med, FACS Stem Cell Lab, Aarau, Switzerland
[8] Erasmus MC, Dept Immunol, Erasmus MC, Rotterdam, Netherlands
[9] Rostock Univ Med Ctr, Div Internal Med Med Clin Hematol Oncol & Palliat, Special Hematol Lab, Rostock, Germany
[10] Leiden Univ, Dept Immunohematol & Blood Transfus, Med Ctr, Leiden, Netherlands
关键词
Fluorochromes; Antibody panel combination; Multicolor flow cytometry; DYES; NANOCRYSTALS; FLUORESCENCE; EXPRESSION; REAGENTS;
D O I
10.1016/j.jim.2019.06.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorochrome selection is a key step in designing multi-color antibody panels. The list of available fluorochromes is continuously growing, fitting current needs in clinical flow cytometry to simultaneously use more markers to better define multiple leukocyte subpopulations in a single tube. Several criteria guide fluorochrome selection: i) the fluorescence profiles (excitation and emission), ii) relative brightness, iii) fluorescence overlap, iv) fluorochrome stability, and v) reproducible conjugation to antibodies. Here we used 75 samples (45 bone marrow and 30 blood) to illustrate EuroFlow strategies for evaluation of compatible fluorochromes, and how the results obtained guide fluorochrome selection as a critical step in the antibody-panel building process. Our results allowed identification of optimal fluorescence profiles (e.g. higher fluorescence intensity and/or resolution with limited fluorescence overlap into neighbor channels) for brilliant violet (BV)421 and BV510 in the violet laser and allophycocyanin (APC) hilite 7 (H7) or APC C750 in the red laser vs. other candidate fluorochromes generally applied for the same detectors and here evaluated. Moreover, evaluation of the same characteristics for another group of fluorochromes (e.g. BV605, BV650, PE CF594, AF700 or APC AF700) guided selection of the most appropriate fluorochrome conjugates to be combined in a multi-color antibody panel. Albeit this is a demanding approach, it could be successfully applied for selection of fluorochrome combinations for the EuroFlow antibody panels for diagnosis, classification and monitoring of hematological malignancies and primary immunodeficiencies. Consequently, sets of 8-, 10- and 12-color fluorochrome combinations are proposed as frame of reference for initial antibody panel design.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Multi-color flow cytometry for evaluating age-related changes in memory lymphocyte subsets in dogs
    Withers, Sita S.
    Moore, Peter F.
    Chang, Hong
    Choi, Jin W.
    McSorley, Stephen J.
    Kent, Michael S.
    Monjazeb, Arta M.
    Canter, Robert J.
    Murphy, William J.
    Sparger, Ellen E.
    Rebhun, Robert B.
    DEVELOPMENTAL AND COMPARATIVE IMMUNOLOGY, 2018, 87 : 64 - 74
  • [12] MRD Testing in Plasma Cell Myeloma: Is Next Generation Multi-Color Flow Cytometry Alone Sufficient?
    Al-Ghamdi, Yahya
    Mathew, Susan
    Geyer, Julia
    Rosenbaum, Cara
    Rossi, Adriana
    Tam, Wayne
    Niesvizky, Ruben
    Chadburn, Amy
    LABORATORY INVESTIGATION, 2020, 100 (SUPPL 1) : 1248 - 1249
  • [13] MRD Testing in Plasma Cell Myeloma: Is Next Generation Multi-Color Flow Cytometry Alone Sufficient?
    Al-Ghamdi, Yahya
    Mathew, Susan
    Geyer, Julia
    Rosenbaum, Cara
    Rossi, Adriana
    Tam, Wayne
    Niesvizky, Ruben
    Chadburn, Amy
    MODERN PATHOLOGY, 2020, 33 (SUPPL 2) : 1248 - 1249
  • [14] Improved identification of leukocyte sub-populations using new bright fluorochrome reagents in multi-color flow cytometric analysis
    Stall, Alan
    Luan, Feng-Jun
    Edinger, Mark
    Jaimes, Maria
    Elia, Jeanne
    Chen, Yu
    JOURNAL OF IMMUNOLOGY, 2012, 188
  • [15] Combination Use of CD4 Aptamer Probe and Antibodies for Multi-Color Flow Cytometry Immunophenotyping Analysis
    O'Hare, J. T.
    Zhang, P.
    Chang, C.
    Zu, Y.
    LABORATORY INVESTIGATION, 2010, 90 : 314A - 315A
  • [16] Utilizing Multi-Color Flow Cytometry and FACS to Simultaneously Examine Effects of Intermittent Hypoxia on Microglia, Neurons, and Astrocytes
    Smith, Stephanie Michelle Crader
    Nikodemova, Maria
    Watters, Jyoti J.
    FASEB JOURNAL, 2012, 26
  • [17] Combination Use of CD4 Aptamer Probe and Antibodies for Multi-Color Flow Cytometry Immunophenotyping Analysis
    O'Hare, J. T.
    Zhang, P.
    Chang, C.
    Zu, Y.
    MODERN PATHOLOGY, 2010, 23 : 314A - 315A
  • [18] Re-evaluation of the function of CCR6 on effector T cells by multi-color flow cytometry
    Poetzl, Johann
    Botteron, Catherine
    Maennel, Daniela N.
    Lechner, Anja
    CYTOMETRY PART A, 2007, 71A (09) : 759 - 759
  • [19] CHEMOIUNE RECEPTOR RESOLUTION AND EFFECTS OF INCUBATION TEMPERATURE AS MEASURED BY STAIN INDEX USING MULTI-COLOR FLOW CYTOMETRY
    Jackson, A.
    Hingorani, R.
    Williams, S.
    CYTOKINE, 2016, 87 : 98 - 98
  • [20] Multi-color flow cytometry comparative analysis with DA-Cell(TM) centrifugation-less washing
    Le Guezennec, Xavier
    JOURNAL FOR IMMUNOTHERAPY OF CANCER, 2017, 5