共 50 条
Validation of the QR1 Antibody for the Evaluation of PD-L1 Expression in Non-Small Cell Lung Adenocarcinomas
被引:7
|作者:
Brandone, Nicolas
[1
]
Mascaux, Celine
[2
,3
]
Caselles, Kevin
[1
]
Rouquette, Isabelle
[4
]
Lantuejoul, Sylvie
[5
,6
]
Garcia, Stephane
[1
]
机构:
[1] Aix Marseille Univ, AP HP, Hop Nord, Dept Pathol, Marseille, France
[2] Aix Marseille Univ, AP HP, Hop Nord, Multidisciplinary Oncol & Therapeut Innovat Dept, Marseille, France
[3] Aix Marseille Univ, CRCM, INSERM, UMR1068,CNRS,UMR7258, Marseille, France
[4] CHU Toulouse, Dept Pathol, IUCT Oncopole, Toulouse, France
[5] UNICANCER, Ctr Leon Berard, Dept Biopathol & Translat Res & Innovat, 28 Rue Laennec, Lyon, France
[6] Grenoble Alpes Univ, Inst Adv Biosci, INSERM, U1209,CNRS 5309, La Tronche, France
关键词:
lung cancer;
immunotherapy;
immunohistochemistry;
antibody validation;
programmed cell death ligand 1;
SQUAMOUS-CELL;
OPEN-LABEL;
CANCER;
IMMUNOHISTOCHEMISTRY;
PEMBROLIZUMAB;
DOCETAXEL;
BIOMARKERS;
NIVOLUMAB;
BLOCKADE;
MELANOMA;
D O I:
10.1097/PAI.0000000000000758
中图分类号:
R602 [外科病理学、解剖学];
R32 [人体形态学];
学科分类号:
100101 ;
摘要:
The evaluation of Programmed cell Death Ligand 1 (PD-L1) expression in the tumor cells with immunohistochemistry is a mandatory diagnostic step in the treatment of lung cancer. It is important to utilize validated antibodies that can reliably detect PD-L1 positive cells. Different antibodies have already been studied. In this present study, we compared a new clone (QR1, Quartett) with reference clones to determine if it can be used in place of previously identified reference clones. We built a tissue micro array (TMA) from 110 lung adenocarcinomas and compared it using immunohistodetection of four different clones: QR1, 22c3, Sp263, and E1L3N. We analyzed the correlation between the sample duplicates for each clone and then a correlation and the concordance between the clones were calculated. A total of 101 patients were exploitable; the duplicates for each clone had a strong correlation. The correlation was the strongest (r=0.82) between QR1 and 22c3 and less strong with the other clones. Totals of 78%, 79%, and 97% of the QR1 cases were concordant with 22c3 for the thresholds of <1%, 1% to 49%, and >= 50%, respectively. The sensitivities and specificities of QR1, compared with 22c3, were >75% and 81%, respectively. PD-L1 expression, analyzed in lung adenocarcinomas with QR1, is highly correlated and concordant with the main reference clone used in most laboratories (22c3). It can be used to replace the latter in clinical routine.
引用
收藏
页码:23 / 29
页数:7
相关论文