Concerning exergy efficiency evaluation of heat recovery exchangers for air handling units

被引:12
|
作者
Martinaitis, Vytautas [1 ]
Streckiene, Giedre [1 ]
机构
[1] Vilnius Gediminas Tech Univ, Dept Bldg Energet, Sauletekio Ave 11, LT-10223 Vilnius, Lithuania
关键词
exergy analysis; efficiency; heat recovery; heat exchanger; near-environmental temperature; Carnot factor; 2ND LAW; PERFORMANCE; SYSTEMS; ENERGY; DEFINITION;
D O I
10.1504/IJEX.2016.077432
中图分类号
O414.1 [热力学];
学科分类号
摘要
The energy chain of building energy services begins with primary energy resources and ends with building services systems (BSS). The analysis for such chain and its' elements should rely on fundamentals of thermodynamics. This paper pays attention to one of them that exergy efficiency is in the range of 0-1. In this study, exergy analysis of heat recovery exchangers for air handling units is carried out. Special attention is paid to the direction of thermal exergy flow when temperatures inducing heat transfer are close to a near-environmental temperature. On the basis of the proposed methodology, the dependency of exergy efficiency on dimensionless temperature and thermal recuperator efficiency is discussed. It is important to take the dimensionless temperature interval 0-1 into account. Here the exergy efficiency values are the lowest. Design and management measures should be used to avoid operating a heat exchanger there.
引用
收藏
页码:381 / 404
页数:24
相关论文
共 50 条
  • [31] Energy and exergy analysis of a modified air handling unit assisted by phase change material, heat recovery unit, and solar energy
    Faramarzi, Saman
    Asadzadeh, Seyed Mohammad Mehdi
    Hassani, Mohammad Reza Mohammad
    Abdollahi, Seyyed Amirreza
    Zarehzadeh, Reza
    Mafi, Mostafa
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [32] Synergization of air handling units for high energy efficiency in office buildings: Implementation methodology and performance evaluation
    Yu, Yuebin
    Liu, Mingsheng
    Li, Haorong
    Yu, Daihong
    Loftness, Vivian
    ENERGY AND BUILDINGS, 2012, 54 : 426 - 435
  • [33] Exergy efficiency of a ventilation heat recovery exchanger at a variable reference temperature
    Martinaitis, Vytautas
    Bielskus, Juozas
    Janusevicius, Karolis
    Bareika, Paulius
    MECHANIKA, 2017, 23 (01): : 70 - 77
  • [34] Experimental investigation of energy and exergy efficiency of a pulsating heat pipe for chimney heat recovery
    Khodami, R.
    Nejad, A. Abbas
    Khabbaz, M. R. Ali
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2016, 16 : 11 - 17
  • [35] AN INTEGRATED OUTSIDE AIR CONTROL OF AIR HANDLING UNITS IN OFFICE BUILDINGS FOR ENERGY EFFICIENCY
    Yu, Y. B.
    Liu, M. S.
    Yu, D. H.
    Loftness, V.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 1265 - 1271
  • [36] Long-term energy and exergy analysis of heat pumps with different types of ground and air heat exchangers
    Habibi, Mohammad
    Hakkaki-Fard, Ali
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 414 - 433
  • [37] Heat Recovery Unit Failure Detection in Air Handling Unit
    Madhikermi, Manik
    Yousefnezhad, Narges
    Framling, Kary
    ADVANCES IN PRODUCTION MANAGEMENT SYSTEMS: SMART MANUFACTURING FOR INDUSTRY 4.0, APMS 2018, 2018, 536 : 343 - 350
  • [38] ILKA Glass Tube Heat Exchangers for the Recovery of Heat from Exhaust Air.
    Nadler, T.
    Thoms, P.
    Luft- und Kaltetechnik Karlsruhe, 1985, 21 (01): : 18 - 22
  • [39] Maximizing Efficiency of Earth-Air Heat Exchangers with Galvanized Blocks
    Bersch Domingues A.M.
    de Alencar Ramalho J.V.
    Fernando H.J.
    Defect and Diffusion Forum, 2023, 427 : 75 - 84
  • [40] Evaluation of flow maldistribution in air-cooled heat exchangers
    Habib, M. A.
    Ben-Mansour, R.
    Said, S. A. M.
    Al-Qahtani, M. S.
    Al-Bagawi, J. J.
    Al-Mansour, K. M.
    COMPUTERS & FLUIDS, 2009, 38 (03) : 677 - 690