Improving the Energy and IAQ Performance of Ventilation Systems in Dutch Dwellings

被引:7
|
作者
van Holsteijn, Rob C. A. [1 ]
Li, William L. [1 ]
Valk, Harm J. J. [2 ]
Kornaat, Wim [3 ]
机构
[1] Van Holsteijn Kemna BV VHK, Elekt Weg 14, Delft, Netherlands
[2] Nieman Raadgevende Ingenieurs, Atoomweg 400, Utrecht, Netherlands
[3] TNO, Dept Heat Transfer & Fluid Dynam, Stieltjesweg 1, Delft, Netherlands
关键词
ventilation systems; IAQ performance; energy performance; system improvement;
D O I
10.1080/14733315.2016.11684093
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
MONICAIR - MONItoring & Control of Air quality in Individual Rooms - is a pre-competitive field research project of a broad consortium of Dutch ventilation unit manufacturers and research institutes, supported by the Dutch government. The first aim of the project is to investigate and compare the indoor air quality (IAQ) performance and energy characteristics during the heating season of ten different mechanical ventilation solutions in dwellings that meet strict air-tightness standards and comply with current building regulations. The second goal is to further improve the ventilation systems on their IAQ-performance while minimizing their energy consumption. Over a full year 62 residential dwellings were monitored with, in each habitable room, sensors for occupancy, CO2, relative humidity and air temperature. Power consumption of the mechanical ventilation units was also continuously monitored. The ventilation solutions included traditional mechanical exhaust ventilation or MEV systems (systems with mechanical exhaust in the wet rooms), state-of-the-art MEV systems (systems with mechanical exhaust in all rooms), as well as local and central balanced systems with heat recovery (MVHR-systems), with various types of controls. Although all systems under investigation comply with building codes, the data show that huge differences occur in both the IAQ and energy performance. CO2 excess dose (above 1200 ppm) may vary per dwelling from 10 to 850 kppmh per person per heating season, resulting in a situation in which respectively 1 to approximately 85% of the time spent at home, the ventilation is not sufficient in the room that one occupies. Real life primary energy consumption varies from 23 MJ/m(2) for centralized ventilation systems with heat recovery to 144 MJ/m(2) for traditional MEV-systems.
引用
收藏
页码:363 / 370
页数:8
相关论文
共 50 条
  • [1] Evaluating the IAQ and energy performance of ventilation systems in multifamily buildings
    Kiani, Zohreh
    Eddine, Ali Alexander Nour
    Taurines, Kevin
    Mendonca, Katia Cordeiro
    Abadie, Marc
    53RD AICARR INTERNATIONAL CONFERENCE FROM NZEB TO ZEB: THE BUILDINGS OF THE NEXT DECADES FOR A HEALTHY AND SUSTAINABLE FUTURE, 2024, 523
  • [2] IMPROVING VENTILATION SYSTEMS FOR CAVE DWELLINGS IN GONGXIAN, CHINA
    LIU, JZ
    HAN, YW
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 1989, 4 (02) : 225 - 230
  • [3] Modeling ventilation and radon in new Dutch dwellings
    Janssen, MPM
    INDOOR AIR, 2003, 13 (02) : 118 - 127
  • [4] Optimal and robust control of outdoor ventilation airflow rate for improving energy efficiency and IAQ
    Wang, SW
    Xu, XH
    BUILDING AND ENVIRONMENT, 2004, 39 (07) : 763 - 773
  • [5] Uncertainty quantification: For an IAQ and energy performance assessment method for smart ventilation strategies
    Poirier, Baptiste
    Guyot, Gaelle
    Woloszyn, Monika
    BUILDING AND ENVIRONMENT, 2024, 266
  • [6] Systems studies of ventilation configurations involving air purification and energy recovery - Energy efficiency and IAQ
    Dobbs, Gregory M.
    Lemcof, Norberto O.
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 377 - 383
  • [7] ASHRAE IAQ 2010: Airborne Infection Control-Ventilation, IAQ & Energy
    Sekhar, Chandra
    Olesen, Bjarne
    HVAC&R RESEARCH, 2012, 18 (04): : 549 - 551
  • [8] LCA-based environmental assessment of the use and maintenance of heating and ventilation systems in Dutch dwellings
    Blom, Inge
    Itard, Laure
    Meijer, Arjen
    BUILDING AND ENVIRONMENT, 2010, 45 (11) : 2362 - 2372
  • [9] A combined energy and IAQ assessment of the potential value of commissioning residential mechanical ventilation systems
    Turner, William J. N.
    Logue, Jennifer M.
    Wray, Craig P.
    BUILDING AND ENVIRONMENT, 2013, 60 : 194 - 201
  • [10] Monitoring energy performance improvement: insights from Dutch housing association dwellings
    van der Bent, Herman S.
    Visscher, Henk J.
    Meijer, Arjen
    Mouter, Niek
    BUILDINGS & CITIES, 2021, 2 (01): : 779 - 796