Improving the Energy and IAQ Performance of Ventilation Systems in Dutch Dwellings

被引:7
|
作者
van Holsteijn, Rob C. A. [1 ]
Li, William L. [1 ]
Valk, Harm J. J. [2 ]
Kornaat, Wim [3 ]
机构
[1] Van Holsteijn Kemna BV VHK, Elekt Weg 14, Delft, Netherlands
[2] Nieman Raadgevende Ingenieurs, Atoomweg 400, Utrecht, Netherlands
[3] TNO, Dept Heat Transfer & Fluid Dynam, Stieltjesweg 1, Delft, Netherlands
关键词
ventilation systems; IAQ performance; energy performance; system improvement;
D O I
10.1080/14733315.2016.11684093
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
MONICAIR - MONItoring & Control of Air quality in Individual Rooms - is a pre-competitive field research project of a broad consortium of Dutch ventilation unit manufacturers and research institutes, supported by the Dutch government. The first aim of the project is to investigate and compare the indoor air quality (IAQ) performance and energy characteristics during the heating season of ten different mechanical ventilation solutions in dwellings that meet strict air-tightness standards and comply with current building regulations. The second goal is to further improve the ventilation systems on their IAQ-performance while minimizing their energy consumption. Over a full year 62 residential dwellings were monitored with, in each habitable room, sensors for occupancy, CO2, relative humidity and air temperature. Power consumption of the mechanical ventilation units was also continuously monitored. The ventilation solutions included traditional mechanical exhaust ventilation or MEV systems (systems with mechanical exhaust in the wet rooms), state-of-the-art MEV systems (systems with mechanical exhaust in all rooms), as well as local and central balanced systems with heat recovery (MVHR-systems), with various types of controls. Although all systems under investigation comply with building codes, the data show that huge differences occur in both the IAQ and energy performance. CO2 excess dose (above 1200 ppm) may vary per dwelling from 10 to 850 kppmh per person per heating season, resulting in a situation in which respectively 1 to approximately 85% of the time spent at home, the ventilation is not sufficient in the room that one occupies. Real life primary energy consumption varies from 23 MJ/m(2) for centralized ventilation systems with heat recovery to 144 MJ/m(2) for traditional MEV-systems.
引用
收藏
页码:363 / 370
页数:8
相关论文
共 50 条
  • [41] What should the ventilation objectives be for retrofit energy efficiency interventions of dwellings?
    Milner, James
    Hamilton, Ian
    Shrubsole, Clive
    Das, Payel
    Chalabi, Zaid
    Davies, Michael
    Wilkinson, Paul
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2015, 36 (02): : 221 - 229
  • [42] Energy and IAQ impacts of CO2-based demand-controlled ventilation
    Carpenter, Stephen C.
    ASHRAE Transactions, 1996, 102 (02): : 80 - 88
  • [43] Energy and IAQ impacts of CO2-based demand-controlled ventilation
    Carpenter, SC
    ASHRAE TRANSACTIONS 1996, VOL 102, PT 2, 1996, 102 : 80 - 88
  • [44] Ventilation requirements based on carbon dioxide concentration criteria: implications on IAQ and energy use
    Odriozola-Maritorena, Moises
    Martin, Koldobika
    Flores, Ivan
    Campos-Celador, Alvaro
    Maria Sala, Jose
    INTERNATIONAL JOURNAL OF VENTILATION, 2018, 17 (04) : 256 - 271
  • [45] Ventilation and Filtration Control Strategy Considering PM2.5, IAQ, and System Energy
    Kim, Ji-Hye
    Kim, Hee-Gang
    Yeo, Myoung-Souk
    ATMOSPHERE, 2020, 11 (11)
  • [46] ENERGY PERFORMANCE LABELS FOR DWELLINGS VERSUS REAL ENERGY CONSUMPTION
    Staepels, Liesbeth
    Verbeeck, Griet
    Roels, Staf
    Van Gelder, Liesje
    Bauwens, Geert
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 1698 - 1705
  • [47] Numerical study of solar-wind tower systems for ventilation of dwellings
    Nouanegue, H. F.
    Alandji, L. R.
    Bilgen, E.
    RENEWABLE ENERGY, 2008, 33 (03) : 434 - 443
  • [48] Simplified model for thermal comfort, IAQ and energy savings in rooms conditioned by displacement ventilation aided with transient personalized ventilation
    Al Assaad, Douaa
    Habchi, Carine
    Ghali, Kamel
    Ghaddar, Nesreen
    ENERGY CONVERSION AND MANAGEMENT, 2018, 162 : 203 - 217
  • [49] Improving Energy and Performance with Spintronics Caches in Multicore Systems
    Tuohy, William
    Ma, Cong
    Nandkar, Pushkar
    Borse, Nishant
    Lilja, David J.
    EURO-PAR 2014: PARALLEL PROCESSING WORKSHOPS, PT II, 2014, 8806 : 279 - 290
  • [50] Logistic regression based multi-objective optimization of IAQ ventilation system considering healthy risk and ventilation energy
    Pyo, Sehee
    Lee, SeungChul
    Kim, MinJeong
    Kim, Jeong Tai
    Yoo, ChangKyoo
    6TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, 2014, 62 : 583 - 589