Evaluation and Analysis Model of Stray Current in the Metro Depot

被引:23
|
作者
Lin, Sheng [1 ]
Huangfu, Yang [1 ]
Zhou, Qi [1 ]
Wang, Aimin [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Elect Engn, Chengdu 610031, Peoples R China
基金
中国国家自然科学基金;
关键词
Rails; Earth; Mathematical model; Analytical models; Resistors; Resistance; Finite element analysis; DC traction supply system; metro depot; nodal analysis method; one-way conduction device (OWCD); stray current; GROUNDING SCHEMES; RAILWAY;
D O I
10.1109/TTE.2020.3035395
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the rapid development of the dc metro system, the hazard of stray current is increasingly serious. Due to the direct grounding of the track and the lack of a stray current collector system (SCCS), the metro depot has become a weak link in the protection against the stray current. In order to evaluate and analyze the stray current distribution of the metro depot, the evaluation model of stray current in the metro depot is proposed in this article. Based on the piecewise-linearized volt-ampere characteristic, the one-way conduction device (OWCD) of the depot is modeled by a current source paralleled with a resistor. The distribution of stray current in the depot is calculated based on the nodal analysis method. The validity of the proposed evaluation model is verified by comparing the calculation results with the field data. Moreover, based on the proposed evaluation model, the distribution of stray current in the depot when the train operates at different positions is analyzed. The results show that the train in traction operation on the mainline far away from the depot is more likely to aggravate the stray current in the depot than when it is close to the depot.
引用
收藏
页码:1780 / 1794
页数:15
相关论文
共 50 条
  • [21] A Field-Circuit Coupling Diffusion Model for Stray Current of DC Metro System
    Liu, Wei
    Pan, Zhe
    Tang, Yuning
    Zhou, Linjie
    Ahmed Bhatti, Ashfaque
    Niu, Jianbang
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2024, 10 (03): : 4793 - 4808
  • [22] A Research on Inductance Forcedly Absorbing Current to Reduce Stray Current in Metro
    Wang, Ying
    Wen, Tianqi
    Yu, Fan
    Mao, Yuanfa
    Wu, Qian
    Liu, Shijie
    Liu, Fanglin
    He, Hongyun
    Wang, Ronggui
    PROCEEDINGS OF THE 2021 IEEE 16TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2021), 2021, : 779 - 782
  • [23] Analysis of Distribution of Metro Stray Current in Urban Power Grid and Its Influencing Factors
    Shi, Yuntao
    Zhao, Liping
    Lin, Sheng
    Ren, Yonghao
    Wang, Aimin
    Wu, Guoxing
    Dianwang Jishu/Power System Technology, 2021, 45 (05): : 1951 - 1957
  • [24] Modeling and Influencing Factors Analysis of Dynamic Potential Distribution Caused by Metro Stray Current
    Ni Y.
    Zeng X.
    Yu K.
    Cheng X.
    Tang Y.
    Zhuo C.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (23): : 9059 - 9071
  • [25] Study on Method of Data Fusion in Metro Stray Current Monitoring
    Wang, Yu-qiao
    Li, Wei
    Yang, Xue-feng
    Ye, Guo
    Ge, Xi-yun
    Su, Xiu-ping
    PROCEEDINGS OF THE 2011 INTERNATIONAL CONFERENCE ON INFORMATICS, CYBERNETICS, AND COMPUTER ENGINEERING (ICCE2011), VOL 1: INTELLIGENT CONTROL AND NETWORK COMMUNICATION, 2011, 110 (01): : 193 - 201
  • [26] Study on Dynamic Characteristics of Metro Stray Current Based on CDEGS
    Liu, Mingjie
    Lin, Sheng
    Zhao, Liping
    Lin, Xiaohong
    Chen, Liang
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL AND INFORMATION TECHNOLOGIES FOR RAIL TRANSPORTATION (EITRT) 2017: TRANSPORTATION, 2018, 483 : 571 - 578
  • [27] STRAY EARTH CURRENT CONTROL WASHINGTON, DC METRO SYSTEM
    SHAFFER, RE
    FITZGERALD, JH
    MATERIALS PERFORMANCE, 1981, 20 (04) : 9 - 15
  • [28] Research on stray current distribution of Metro based on Numerical Simulation
    Lin, Yanhua
    Li, Kunpeng
    Su, Mengmeng
    Meng, Yongchang
    2018 JOINT IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND 2018 IEEE ASIA-PACIFIC SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC/APEMC), 2018,
  • [29] Study on Method of Data Fusion in Metro Stray Current Monitoring
    Wang Yu-qiao
    Li Wei
    Yang Xue-feng
    Ye Guo
    Ge Xi-yun
    Su Xiu-ping
    2010 INTERNATIONAL COLLOQUIUM ON COMPUTING, COMMUNICATION, CONTROL, AND MANAGEMENT (CCCM2010), VOL I, 2010, : 320 - 323
  • [30] Influence and protection of metro stray current on pipeline sacrificial anode
    Dong L.
    Jiang Z.
    Du Y.
    Lu M.
    Meng Q.