Detection of circumferential cracks in heat exchanger tubes using pulsed eddy current testing

被引:34
|
作者
Yu, Zhaohu [1 ]
Fu, Yuewen [1 ]
Jiang, Lifan [1 ]
Yang, Fan [1 ]
机构
[1] Nanchang Hangkong Univ, Key Lab Nondestruct Testing, Minist Educ, Nanchang 330063, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat exchanger tube; Pulsed eddy current; Circumferential crack; CURRENT PROBES;
D O I
10.1016/j.ndteint.2021.102444
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Heat exchanger tubes in industrial pressure vessels typically require periodic inspection, and detection of circumferential cracks is one of the foremost issues. In this study, the pulsed eddy current method was used for the detection, and new types of probes were designed. Transverse probes were designed to render the eddy currents perpendicular to circumferential cracks to improve detection sensitivity, and the corresponding numerical simulations showed that the eddy currents were approximately perpendicular to the circumferential cracks along more than half of the tube circumference. Thus, two probes could cover the entire circumference for more economical inspection to be achieved. The experiments were performed on copper and steel tubes. The results show that when compared to longitudinal probes, the designed transverse probes significantly improved the detection sensitivity towards circumferential cracks. Particularly, the effectiveness of the proposed method is shown regarding detection of deep defects with good sensitivity in steel tubes without saturation magnetization.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Characterization of small cracks in eddy current testing
    Le Bihan, Y.
    Pavo, J.
    Marchand, C.
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2008, 43 (02): : 231 - 237
  • [43] MULTIFREQUENCY EDDY CURRENT TESTING OF SMALL BORE TUBES IN HEAT EXCHANGERS.
    Takahashi, Akira
    Naoe, Masahisa
    Kanamori, Teruo
    Washida, Michio
    Sumitomo Keikinzoku Giho/Sumitomo Light Metal Technical Reports, 1984, 25 (02): : 99 - 108
  • [44] Measurement of Accumulated Height of Exfoliated Oxide Scales in Austenitic Boiler Tubes Using Pulsed Eddy Current Testing
    Xu, Zhiyuan
    Zhu, Jingzhe
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2020, 56 (04) : 350 - 360
  • [45] An approach to reconstruction of natural cracks using signals of eddy current testing
    Chen, ZM
    Miya, K
    Kurokawa, M
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (III), 1999, 15 : 233 - 240
  • [46] Quantification of depth and classification of cracks using pulsed eddy current test technology
    College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
    不详
    Yi Qi Yi Biao Xue Bao, 2009, 6 (1190-1194):
  • [47] Measurement of electromagnetic properties of heat exchanger tubes with model-based eddy current technique
    Todorov, Evgueni
    NDT & E INTERNATIONAL, 2012, 48 : 70 - 76
  • [48] Massively multiplexed eddy current testing and its comparison with pulsed eddy current testing
    Brown, DJ
    Hils, CM
    Johnson, MJ
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 23A AND 23B, 2004, 23 : 390 - 397
  • [49] Damage detection of surface cracks in metallic parts by pulsed Eddy-Current probe
    Aoukili, Abdeslam
    Khamlichi, Abdellatif
    11TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING, INTER-ENG 2017, 2018, 22 : 209 - 214
  • [50] Investigation on Velocity Effect in Pulsed Eddy Current Technique for Detection Cracks in Ferromagnetic Material
    Yuan, Fei
    Yu, Yating
    Liu, Bowen
    Tian, Guiyun
    IEEE TRANSACTIONS ON MAGNETICS, 2020, 56 (09)