摘要
Abdominal Aorta Aneurysm (AAA) affects aorta, especially above the iliac bifurcation where the Wall Shear Stress (WSS) is greater. Consequence may be fatal in case of breakage; a way to treat it is Endovascular Aneurysm Repair (EVAR) where a stent graft is placed inside the aorta without open surgery requirement. Because of the standards, stent graft can be chosen between several sizes: in some cases, this device cannot fit perfectly with the anatomy of the patient and this can lead to a not optimal behavior of the prosthesis and further complications. This study present a method to design and test specific custom-fit stent graft able to better adapt to the patient artery improving the efficiency of the prosthesis and reducing the risk of the migration of the graft as well as the fabric torn. The design method is based on a 3D geometric model of the aorta, generated from CT scan data. Centrelines and geometric data for cross sections along the aorta are the inputs necessary to define the mesh of the stent. A custom algorithm is developed to size the stent in relation to the geometric data of the specific patient; when the frame of the prosthesis is defined, a CAD based Loft Surface has used to define surfaces between the stent rings. For the bifurcation, again CAD-based Boundary Surfaces is used. The described procedure has been also applied in a Augmented Virtual Reality simulation of the EVAR and, finally, it permits a CFD simulation to evaluate the behavior of the prosthesis inserted into the aorta.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] The impact of stent graft evolution on the results of endovascular abdominal aortic aneurysm repair
    Tadros, Rami O.
    Faries, Peter L.
    Ellozy, Sharif H.
    Lookstein, Robert A.
    Vouyouka, Ageliki G.
    Schrier, Rachel
    Kim, Jamie
    Marin, Michael L.
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (06) : 1518 - 1527
  • [32] Abdominal aortic aneurysm repair with the Zenith stent graft: Short to midterm results
    Abraham, CZ
    Chuter, TAM
    Reilly, LM
    Okuhn, SP
    Pethan, LK
    Kerlan, RB
    Sawhney, R
    Buck, DG
    Gordon, RL
    Messina, LM
    JOURNAL OF VASCULAR SURGERY, 2002, 36 (02) : 217 - 225
  • [33] Gender differences in endovascular abdominal aortic aneurysm repair with the AneuRx stent graft
    Wolf, YG
    Arko, FR
    Hill, BB
    Olcott, C
    Harris, EJ
    Fogarty, TJ
    Zarins, CK
    JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) : 882 - 886
  • [34] Stent-graft migration after endovascular repair of abdominal aortic aneurysm
    Kalliafas, S
    Albertini, JN
    Macierewicz, J
    Yusuf, SW
    Whitaker, SC
    Davidson, I
    Hopkinson, BR
    JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 (06) : 743 - 747
  • [35] Initial experience with the AneuRx Stent Graft for the treatment of infrarenal abdominal aortic aneurysm
    Huang, SC
    Liang, PC
    Wang, SS
    Kao, HL
    Chen, YS
    Ko, WJ
    Liu, HM
    Liau, CS
    Lin, FY
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2005, 104 (10) : 768 - 771
  • [36] A case of intestinal obstruction following stent graft placement for an abdominal aortic aneurysm
    Kaneda, T
    Takamoto, S
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1999, 63 (07): : 567 - 568
  • [37] STENT GRAFT FOR TREATMENT OF AN ABDOMINAL AORTIC-ANEURYSM - LEAK DETECTED BY CT
    KRYSL, J
    VESELY, TM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) : 659 - 661
  • [38] Stent Graft Change Detection After Endovascular Abdominal Aortic Aneurysm Repair
    Maiora, Josu
    Garcia, Guillermo
    Tapia, Arantxa
    Macia, Ivan
    Haitz Legarreta, Jon
    Paloc, Celine
    Grana, Manuel
    de Blas, Mariano
    INTELLIGENT DATA ENGINEERING AND AUTOMATED LEARNING, PROCEEDINGS, 2009, 5788 : 656 - +
  • [39] Anaphylactic Reaction during Implantation of Ovation Abdominal Stent Graft in Patients with Abdominal Aortic Aneurysm
    Siani, Andrea
    Accrocca, Federico
    De Vivo, Gennaro
    Mounayergi, Federica
    Siani, Luca Maria
    Antonelli, Roberto
    ANNALS OF VASCULAR SURGERY, 2017, 39 : 289.e1 - 289.e4
  • [40] Stent graft in abdominal aortic aneurysm collapsed suddenly after thoracic endovascular aortic repair
    Takagi, Sho
    Goto, Yoshihiro
    Yanagisawa, Junji
    Nakasu, Akio
    BMJ CASE REPORTS, 2021, 14 (12)