Transcatheter aortic valve implantation for aortic insufficiency in patients with left ventricular assistance

被引:6
|
作者
Ancona, Marco B. [1 ]
Moroni, Francesco [1 ]
Romano, Vittorio [1 ]
Agricola, Eustachio [2 ,3 ]
Esposito, Antonio [3 ,4 ]
Ajello, Silvia [5 ]
De Bonis, Michele [3 ,6 ]
Cappelletti, Alberto M. [7 ]
Zangrillo, Alberto [3 ,5 ]
Scandroglio, Anna Mara [5 ]
Montorfano, Matteo [1 ]
机构
[1] IRCCS Osped San Raffaele, Emodinam & Cardiol Interventist, Via Olgettina 60, I-20132 Milan, Italy
[2] IRCCS Osped San Raffaele, Lab Ecocardiog, Milan, Italy
[3] Univ Vita Salute San Raffaele, Milan, Italy
[4] IRCCS Osped San Raffaele, UO Radiol, Milan, Italy
[5] IRCCS Osped San Raffaele, Unita Terapia Intens Cardiotorac, Milan, Italy
[6] IRCCS Osped San Raffaele, UO Cardiochirurg, Milan, Italy
[7] IRCCS Osped San Raffaele, UTIC, Milan, Italy
关键词
Aortic regurgitation; Balloon-expandable prosthesis; Left ventricular assist device; Transcatheter aortic valve implantation; DEVICE SUPPORT; REGURGITATION; REPLACEMENT; MANAGEMENT; TAVI;
D O I
10.1714/3578.35633
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aortic valve regurgitation is a not negligible complication of prolonged support with continuous-flow left ventricular assist device (LVAD) and is associated with recurrence of heart failure and reduced survival. Transcatheter aortic valve implantation has been described as a feasible option in this setting, usually with self-expanding prosthesis. Giving the absence of valvular calcification, a proper prosthesis oversizing should be guaranteed in order to achieve sufficient sealing and avoid prosthesis migration or paravalvular leak. Current self-expanding prosthesis may be too small to fit aortic annulus anatomies without calcification and with the need of significant oversize. We report the first case of 32 mm balloon expandable Myval prosthesis implantation in a patient with LVAD-related aortic regurgitation. Large balloon-expandable prosthesis can be considered when a significant oversize is needed.
引用
收藏
页码:39S / 42S
页数:4
相关论文
共 50 条
  • [31] The miracle of left ventricular recovery after transcatheter aortic valve implantation
    Dauerman, Harold L.
    Lahoud, Rony
    EUROINTERVENTION, 2024, 20 (08) : E463 - E464
  • [32] Left ventricular remodeling after transcatheter aortic valve implantation (TAVI)
    Sebastian Gruenig
    Florian Bönner
    Yang Chul Boering
    Marc W Merx
    Tobias Zeus
    Malte Kelm
    Mirja Neizel
    Burkhard Sievers
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [33] Echocardiographic Outcomes Following Transcatheter Aortic Valve Implantation in Patients with Severe Aortic Stenosis and Left Ventricular Dysfunction
    Al-Lamee, Rasha
    Fraccaro, Chiara
    Grinaldi, Antonio
    Piraino, Daniel
    Napadano, Massimo
    Ielasi, Alfonso
    Tarantini, Giuseppe
    Godino, Cosmo
    Gasparetto, Valeria
    Pittarello, Demetrio
    Latib, Azeem
    Gerosa, Gino
    Mussardo, Marco
    Isabella, Giambattista
    Maisano, Francesco
    Montorfano, Matteo
    Chieffo, Alaide
    Colombo, Antonio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B111 - B111
  • [34] Impact of transcatheter aortic valve implantation with the CoreValve prosthesis in patients with severe aortic stenosis and left ventricular dysfunction
    Munoz-Garcia, Antonio J.
    Jimenez-Navarro, Manuel F.
    Rodriguez-Bailon, Isabel
    Molina-Mora, Maria J.
    Dominguez-Franco, Antonio J.
    Alonso-Briales, Juan H.
    Gomez-Doblas, Juan J.
    Hernandez-Garcia, Jose M.
    de Teresa Galvan, Eduardo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 157 (01) : 124 - 125
  • [35] Left ventricular stiffness predicts outcome in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation
    Conte, Lorenzo
    Fabiani, Iacopo
    Pugliese, Nicola R.
    Giannini, Cristina
    La Carruba, Salvatore
    Angelillis, Marco
    Spontoni, Paolo
    De Carlo, Marco
    Petronio, Anna Sonia
    Di Bello, Vitantonio
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (01): : 6 - 13
  • [36] Transcatheter aortic valve implantation in patients with low gradient aortic stenosis and preserved left ventricular ejection fraction
    Lockwood, S. M.
    Mottram, P. M.
    Cameron, J.
    Moir, W. S.
    EUROPEAN HEART JOURNAL, 2014, 35 : 420 - 420
  • [37] Transcatheter aortic valve implantation for left ventricular assist device-related aortic regurgitation
    Tomii, Daijiro
    Reineke, David
    Hunziker, Lukas
    Pilgrim, Thomas
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2024, 65 (03)
  • [38] Regression of Electrocardiographic Left Ventricular Hypertrophy After Transcatheter Aortic Valve Implantation for Aortic Stenosis
    Tobe, Akihiro
    Tanaka, Akihito
    Tokuda, Yoshiyuki
    Akita, Sho
    Fujii, Taro
    Miki, Yusuke
    Furusawa, Kenji
    Ishii, Hideki
    Usui, Akihiko
    Murohara, Toyoaki
    CIRCULATION JOURNAL, 2021, 85 (07) : 1093 - 1098
  • [39] Long-term Outcomes Of Transcatheter Aortic Valve Replacement For Aortic Insufficiency In Patients With Left Ventricular Assist Devices
    Quach, Kaitlyn
    Shen, Christine
    Parizo, Justin
    Narula, Arvin
    JOURNAL OF CARDIAC FAILURE, 2023, 29 (04) : 623 - 623
  • [40] Percutaneous Transcatheter Closure of the Native Aortic Valve to Treat De Novo Aortic Insufficiency After Implantation of a Left Ventricular Assist Device
    Freed, Benjamin H.
    Paul, Jonathan D.
    Bhave, Nicole M.
    Russo, Mark J.
    Jeevanandam, Valluvan
    Lang, Roberto M.
    Shah, Atman P.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (03) : 358 - 359