Determination of methylmercury in marine sediment samples: Method validation and occurrence data

被引:30
|
作者
Carrasco, Luis [1 ]
Vassileva, Emilia [1 ]
机构
[1] IAEA, Dept Nucl Sci & Applicat, Environm Labs, MC-98000 Monaco, Monaco
关键词
Methylmercury; Gas chromatography-pyrolysis-atomic fluorescence spectrometry; Marine sediments; Sample preparation; Validation; Traceability; Uncertainty; ATOMIC-FLUORESCENCE SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; CAPILLARY GAS-CHROMATOGRAPHY; SOLID-PHASE MICROEXTRACTION; PLASMA-MASS SPECTROMETRY; ENVIRONMENTAL-SAMPLES; MERCURY METHYLATION; ASSISTED EXTRACTION; ORGANIC MERCURY; FISH-TISSUES;
D O I
10.1016/j.aca.2014.10.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of methylmercury (MeHg) in sediment samples is a difficult task due to the extremely low MeHg/THg (total mercury) ratio and species interconversion. Here, we present the method validation of a cost-effective fit-for-purpose analytical procedure for the measurement of MeHg in sediments, which is based on aqueous phase ethylation, followed by purge and trap and hyphenated gas chromatography-pyrolysis-atomic fluorescence spectrometry (GC-Py-AFS) separation and detection. Four different extraction techniques, namely acid and alkaline leaching followed by solvent extraction and evaporation, microwave-assisted extraction with 2-mercaptoethanol, and acid leaching, solvent extraction and back extraction into sodium thiosulfate, were examined regarding their potential to selectively extract MeHg from estuarine sediment IAEA-405 certified reference material (CRM). The procedure based on acid leaching with HNO3/CuSO4, solvent extraction and back extraction into Na2S2O3 yielded the highest extraction recovery, i.e., 94 +/- 3% and offered the possibility to perform the extraction of a large number of samples in a short time, by eliminating the evaporation step. The artifact formation of MeHg was evaluated by high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry (HPLC-ICP-MS), using isotopically enriched (MeHg)-Hg-201 and Hg-202 and it was found to be nonexistent. A full validation approach in line with ISO 17025 and Eurachem guidelines was followed. With this in mind, blanks, selectivity, working range (1-800 pg), linearity (0.9995), recovery (94-96%), repeatability (3%), intermediate precision (4%), limit of detection (0.45 pg) and limit of quantification (0.85 pg) were systematically assessed with CRM IAEA-405. The uncertainty budget was calculated and the major contribution to the combined uncertainty (16.24%, k = 2) was found to arise from the uncertainty associated with recovery (74.1%). Demonstration of traceability of measurement results is also presented. The validated measurement procedure was applied to the determination of MeHg incurred in sediments from a highly polluted and scarcely studied area in the Caribbean region. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:167 / 178
页数:12
相关论文
共 50 条
  • [41] Interlaboratory study to improve the quality control of methylmercury determination in sediment
    Quevauviller, P
    Fortunati, GU
    Filippelli, M
    Baldi, F
    Bianchi, M
    Muntau, H
    APPLIED ORGANOMETALLIC CHEMISTRY, 1996, 10 (07) : 537 - 544
  • [42] A Method for the Routine Determination of Methylmercury in Marine Tissue by GC Isotope Dilution-ICP-MS
    Valdersnes, Stig
    Maage, Amund
    Fliegel, Daniel
    Julshamn, Kare
    JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (04) : 1189 - 1194
  • [43] Determination of heavy metal pollution in depth profile of marine sediment samples from the Strait of Malacca
    Bin Saion, Elias
    Wood, Ab Khalik H.
    Sulaiman, Zainal Abidin
    Alzahrany, Awad A.
    Elias, Md Suhaimi
    Siong, Wee Boon
    FRESENIUS ENVIRONMENTAL BULLETIN, 2007, 16 (10): : 1279 - 1287
  • [44] Determination of NSAIDs in river sediment samples
    Antonic, Jan
    Heath, Ester
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (04) : 1337 - 1342
  • [45] Validation of Total Mercury in Marine Sediment and Biological Samples, Using Cold Vapour Atomic Absorption Spectrometry
    Elezz, Ahmed Abou
    Mustafa Hassan, Hassan
    Abdulla Alsaadi, Hamood
    Easa, Ahmed
    Al-Meer, Saeed
    Elsaid, Khaled
    Ghouri, Zafar Khan
    Abdala, Ahmed
    METHODS AND PROTOCOLS, 2018, 1 (03) : 1 - 14
  • [46] Development of a Method for the Determination of Polychlorinated Biphenyls in Microplastics Present in Marine Samples
    Carro Nieves
    Cobas Julio
    Brikat Nahid
    García Isabel
    Ignacio María
    Mouteira Ana
    Journal of Analytical Chemistry, 2021, 76 : 960 - 974
  • [47] Determination of NSAIDs in river sediment samples
    Jan Antonić
    Ester Heath
    Analytical and Bioanalytical Chemistry, 2007, 387 : 1337 - 1342
  • [48] Development of a Method for the Determination of Polychlorinated Biphenyls in Microplastics Present in Marine Samples
    Nieves, Carro
    Julio, Cobas
    Nahid, Brikat
    Isabel, Garcia
    Maria, Ignacio
    Ana, Mouteira
    JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (08) : 960 - 974
  • [49] Optimization of supercritical fluid extraction gas chromatography of methylmercury in marine samples
    CelaTorrijos, R
    MiguensRodriguez, M
    CarroDiaz, AM
    LorenzoFerreira, RA
    JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) : 191 - 199
  • [50] A simple analytical method for the simultaneous determination of multiple organic pollutants in sediment samples
    Zeng, Xiangying
    Hu, Qiongpu
    He, Lixiong
    Liu, Zhiyang
    Gao, Shutao
    Yu, Zhiqiang
    METHODSX, 2018, 5 : 1089 - 1094