Assessment of LVRT Requirements and Dynamic Behavior of a Mixed PMSG/DFIG Wind Power Plant

被引:1
|
作者
Ribeiro, Renata [1 ]
Boeira, Rafael [1 ]
Leborgne, Roberto Chouhy [1 ]
de Oliveira, Roger Alves [2 ]
Bollen, Math H. J. [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Porto Alegre, RS, Brazil
[2] Lulea Univ Technol, Elect Power Engn Grp, Skelleftea, Sweden
关键词
Power Quality; Voltage Dip; LVRT; FRT; Wind Power; DFIG; PMSG; FED INDUCTION GENERATOR; TURBINES;
D O I
10.1109/TDLA47668.2020.9326154
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work assesses the low voltage ride-through requirements and the dynamic behavior of a mixed PMSG/ DFIG wind power plant. Previous works in the literature applied voltage dips seen at the Point of Common Coupling (PCC) of the wind power plant (WPP) directly, which means that the propagation from the transmission grid to the low-voltage level was not considered. This work aims to show the expected operation of a wind power plant when submitted to voltage dips caused by faults at the transmission level, i.e considering the propagation. Equivalent models of a transmission system and a wind power plant were used to generate five types of dips and to access the behavior of the WPP during these events. The results show the expected ranges during the voltage dips for the active power of the generators as well as for overvoltages and overcurrents of the converters.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] LVRT ability of PMSG wind power system
    Zhang, Mingrui
    Li, Na
    Wang, Zhixin
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2014, 34 (01): : 128 - 134
  • [2] Verification of DFIG and PMSG wind turbines LVRT characteristics through field testing
    Zeng, Hui
    Zhu, Yu
    Liu, Jinsong
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2012,
  • [3] Simulation of LVRT strategy for DFIG wind power system
    Zhu, Ying
    Li, Jianlin
    Zhao, Bin
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2010, 30 (06): : 20 - 24
  • [4] Modeling and LVRT Analysis of DFIG Wind Power System
    Wen, Huiqing
    Cai, Sijie
    2015 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2015,
  • [5] Influences on the LVRT behavior of DFIG wind turbine systems
    Herzog, F.
    Roeder, J.
    Frehn, A.
    Ruhe, N.
    De Doncker, R. W.
    SCIENCE OF MAKING TORQUE FROM WIND, TORQUE 2022, 2022, 2265
  • [6] An Adaptive LVRT Control for DFIG Wind Power System
    Zhang Jian
    Xue Ancheng
    Chen Jinmei
    Bi Tianshu
    Wang Ningbo
    Ma Yanhong
    PROCEEDINGS OF THE 31ST CHINESE CONTROL CONFERENCE, 2012, : 6747 - 6751
  • [8] Dynamic Voltage Restorer to allow LVRT for a DFIG Wind Turbine
    Wessels, Christian
    Gebhardt, Fabian
    Fuchs, Friedrich W.
    IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE 2010), 2010, : 803 - 808
  • [9] Performance Analysis and Research on LVRT of PMSG Wind Power Systems with SDBR
    Ji Tongzhou
    He Xiongfeng
    Li Xianyun
    Liu Kun
    Zhang Mei
    2014 33RD CHINESE CONTROL CONFERENCE (CCC), 2014, : 6953 - 6958
  • [10] LVRT Scheme of PMSG Wind Power Systems Based on Feedback Linearization
    Kim, Ki-Hong
    Jeung, Yoon-Cheul
    Lee, Dong-Choon
    Kim, Heung-Geun
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (05) : 2376 - 2384