Deterioration of Concrete Bridge Decks Containing Epoxy-Coated and Uncoated Reinforcement

被引:1
|
作者
Treat, Corin [1 ]
Dymond, Benjamin Z. [2 ]
机构
[1] Meyer Borgman Johnson, Duluth, MN 55802 USA
[2] Univ Minnesota Duluth, Dept Civil Engn, Duluth, MN 55812 USA
关键词
Deterioration;
D O I
10.1061/(ASCE)BE.1943-5592.0001694
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Bridge decks were constructed in Minnesota from 1973 to 1989 with mixed reinforcement, meaning a top mat of epoxy-coated reinforcement and a bottom mat of uncoated reinforcement, to reduce corrosion. This paper investigated how the deterioration of concrete decks built with mixed reinforcement compared to control structures containing all epoxy-coated reinforcement using rating data from inspection reports. The results were subdivided to indicate how the superstructure type, average daily traffic, route type, wearing surface crack density, and skew affected the condition ratings and deterioration. The mixed reinforcement decks reached worse condition states than the control structures considering the underside of the deck. Mixed reinforcement decks transitioned to the condition state where rehabilitation is often initiated after remaining in the prior condition state for 8.5 years. Bridges with a steel superstructure reached worse condition state ratings. Average daily traffic, route type, wearing surface crack density, and skew did not have consistent behavior considering deck ratings and deterioration. (C) 2021 American Society of Civil Engineers.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Deterioration Rates of Concrete Bridge Decks in Several Climatic Regions
    Chyad, Aqeed Mohsin
    Abudayyeh, Osama
    Zakhil, Fida
    Hakimi, Obaidullah
    2018 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY (EIT), 2018, : 65 - 68
  • [42] A Comprehensive Review of the Key Deterioration Factors of Concrete Bridge Decks
    Ibrahim, Abdelazim
    Abdelkhalek, Sherif
    Zayed, Tarek
    Qureshi, Abdul Hannan
    Abdelkader, Eslam Mohammed
    BUILDINGS, 2024, 14 (11)
  • [43] The effect of epoxy-coated reinforcement and concrete quality on cracking of flat plate slab-column connections
    Abrishami, HH
    Cook, WD
    Mitchell, D
    ACI MATERIALS JOURNAL, 1996, 93 (02) : 121 - 128
  • [44] Experimental and analytical study on bond strength of normal uncoated and epoxy-coated reinforcing bars
    Wang, Xiao-Hui
    Chen, Bing
    Tang, Peng
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 189 : 612 - 628
  • [45] Unexpected deterioration of fusion-bonded epoxy-coated rebars embedded in chloride-contaminated concrete environments
    Singh, DDN
    Ghosh, R
    CORROSION, 2005, 61 (08) : 815 - 829
  • [46] FIRE TEST OF CONCRETE SLAB REINFORCED WITH EPOXY-COATED BARS
    LIN, TD
    ZWIERS, RI
    SHIRLEY, ST
    BURG, RG
    ACI STRUCTURAL JOURNAL, 1989, 86 (02) : 156 - 162
  • [47] Epoxy-coated bars as corrosion control in cracked reinforced concrete
    Lopez-Calvo, H. Z.
    Montes-Garcia, P.
    Kondratova, I.
    Bremner, T. W.
    Thomas, M. D. A.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2013, 64 (07): : 599 - 608
  • [48] Bond of epoxy-coated reinforcement: Coefficient of friction and rib face angle
    Idun, EK
    Darwin, D
    ACI STRUCTURAL JOURNAL, 1999, 96 (04) : 609 - 615
  • [49] BOND OF EPOXY-COATED REINFORCEMENT - COVER, CASTING POSITION, SLUMP, AND CONSOLIDATION
    HADJEGHAFFARI, H
    CHOI, OC
    DARWIN, D
    MCCABE, SL
    ACI STRUCTURAL JOURNAL, 1994, 91 (01) : 59 - 68
  • [50] Study on behaviors of concrete beams reinforced with epoxy-coated bars
    Xue, Weichen