Selvester score predicts implantable cardioverter defibrillator shocks in patients with non-ischemic cardiomyopathy

被引:1
|
作者
Arisoy, Fazil [1 ]
Ozcan Celebi, Ozlem [2 ]
Erbay, Ilke [2 ]
Tufekcioglu, Omac [2 ]
Aydogdu, Sinan [2 ]
Temizhan, Ahmet [2 ]
机构
[1] Kilis State Hosp, Dept Cardiol, Kilis, Turkey
[2] Univ Hlth Sci, Ankara City Hosp, Dept Cardiol, Ankara, Turkey
关键词
ICD; non ischemic cardiomyopathy; Selvester score; shock; SUDDEN CARDIAC DEATH; QRS SCORE; PRIMARY PREVENTION; THERAPY; MANAGEMENT; AMIODARONE;
D O I
10.1002/joa3.12571
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The implantable cardiac defibrillator is the cornerstone of prevention of sudden cardiac death in non-ischemic cardiomyopathy. The Selvester score, which is frequently investigated in ischemic cardiomyopathy, has not been investigated in the field of non-ischemic cardiomyopathy. Aim: The aim of this study was to evaluate the Selvester score for determining appropriate implantable cardiac defibrillator shocks in non-ischemic cardiomyopathy patients. Materials and methods: In all, 131 non-ischemic cardiomyopathy patients were included in the study. A simplified Selvester score was calculated from ECG data. Patients were divided into two groups according to whether they received ICD shock. Results: Of the patients, 28.2% received appropriate implantable cardiac defibrillator shock. The Selvester score was significantly higher in patients receiving appropriate shock when compared to patients with no implantable cardiac defibrillator shocks (8.8 +/- 4.6 vs 7.2 +/- 3.3, P = .040). The median QRS duration was significantly longer in patients receiving appropriate shock than in patients with no shocks (130.14 +/- 35.08 ms vs 120.12 +/- 20.57 ms, P = .045). We determined that the cutoff value for the Selvester score to predict ICD shocks was 6.5 with a sensitivity of 72.0% and a specificity of 83% (AUC = 0.717; %95 GA: 0.627-0.807, P < .001). Conclusion: Selvester score was higher in patients receiving appropriate shock than in patients who did not receive any implantable cardiac defibrillator shock. From this study, the Selvester score is associated with the risk of ventricular tachycardia/ventricular fibrillation in non-ischemic cardiomyopathy so that careful attention is necessary to manage the patients with high Selvester score.
引用
收藏
页码:1046 / 1051
页数:6
相关论文
共 50 条
  • [21] Is there a role to implantable cardioverter defibrillator for primary prevention in non-ischemic dilated cardiomiopathy?
    Neiva, J. N.
    Rodrigues, I. R.
    Cunha, P. S. C.
    Valente, B. V.
    Nogueira Da Silva, N. S.
    Pimenta, R. P.
    Delgado, A. S. D.
    Bras, M. B.
    Ferreira, R. C. F.
    Oliveira, M. O.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1228 - 1228
  • [22] USEFULNESS OF IMPLANTABLE CARDIOVERTER DEFIBRILLATOR IN PRIMARY VERSUS SECONDARY PREVENTION IN PATIENTS WITH ISCHEMIC AND NON ISCHEMIC CARDIOMYOPATHY
    Marti-Almor, J.
    Bazan, V.
    Oliva, X.
    Cian, D.
    Delclos, J.
    Corral, M.
    Mojal, S.
    Bruguera, J.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 : S12 - S13
  • [23] Frontal QRS-T angle as a predictor of appropriate implantable cardioverter-defibrillator therapy in ischemic and non-ischemic cardiomyopathy
    Chandrachamnong, S.
    Wiwatworapan, W.
    Yingchoncharoen, T.
    Ngernsritrakul, T.
    Apiyasawat, S.
    See, O.
    Sritara, P.
    EUROPEAN HEART JOURNAL, 2015, 36 : 395 - 395
  • [24] Device complications and inappropriate implantable cardioverter defibrillator shocks in patients with hypertrophic cardiomyopathy
    Lin, G.
    Nishimura, R. A.
    Gersh, B. J.
    Phil, D.
    Ommen, S. R.
    Ackerman, M. J.
    Brady, P. A.
    HEART, 2009, 95 (09) : 709 - 714
  • [25] PHANTOM SHOCKS IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    Juan, Emerson A.
    Pollack, Marc
    JOURNAL OF EMERGENCY MEDICINE, 2010, 38 (01): : 22 - 24
  • [26] Predictors of Implantable Cardioverter-Defibrillator Use in Patients with Ischemic Cardiomyopathy
    Kelly, Ryan
    Buth, Karen J.
    Heimrath, Olivier
    Basta, Magdy
    Legare, Jean-Francois
    OPEN CARDIOVASCULAR MEDICINE JOURNAL, 2010, 4 : 206 - 213
  • [27] Experiences of shocks in patients with implantable cardioverter defibrillator
    Stromberg, A.
    Hammargard, J.
    Fant, D.
    Johansson, I.
    EUROPEAN HEART JOURNAL, 2007, 28 : 390 - 390
  • [28] Implantable cardioverter defibrillators for primary prevention in patients with ischemic and non-ischemic cardiomyopathy: A meta-analysis
    Jaiswal, Vikash
    Taha, Amira Mohamed
    Joshi, Amey
    Deb, Novonil
    Kanagala, Sai Gautham
    Nebuwa, Chikodili
    Ang, Song Peng
    Halder, Anupam
    Rajak, Kripa
    Jha, Mayank
    Harshakumar, Sreedevi Pallath
    Mattumpuram, Jishanth
    CURRENT PROBLEMS IN CARDIOLOGY, 2024, 49 (02)
  • [29] Impact of the Selvester QRS Score on Prognosis and Myocardial Fibrosis in Non-Ischemic Dilated Cardiomyopathy
    Hiraiwa, Hiroaki
    Okumura, Takahiro
    Kondo, Tom
    Kano, Naoaki
    Watanabe, Naoki
    Fukaya, Kenji
    Sawamura, Akinori
    Morimoto, Ryota
    Bando, Yasuko
    Murohara, Toyoaki
    JOURNAL OF CARDIAC FAILURE, 2016, 22 (09) : S202 - S202
  • [30] Multiple Implantable Cardioverter-Defibrillator Shocks in Ischemic Cardiomyopathy Compels Coronary Vascularization Reassessment
    Gusetu, Gabriel
    Comsa, Horatiu
    Mocanu, Lorena
    Pop, Dana
    JOURNAL OF CARDIOVASCULAR EMERGENCIES, 2023, 9 (04): : 120 - 124