Predictors of pacemaker implantation after transcatheter aortic valve implantation according to kind of prosthesis and risk profile: a systematic review and contemporary meta-analysis

被引:34
|
作者
Bruno, Francesco [1 ,2 ]
D'Ascenzo, Fabrizio [1 ,2 ]
Vaira, Matteo Pio [1 ,2 ]
Elia, Edoardo [1 ,2 ]
Omede, Pierluigi [1 ,2 ]
Kodali, Susheel [3 ]
Barbanti, Marco [4 ]
Rodes-Cabau, Josep [5 ]
Husser, Oliver [6 ]
Sossalla, Samuel [7 ]
Van Mieghem, Nicolas M. [8 ]
Bax, Jeroen [9 ]
Hildick-Smith, David [10 ]
Munoz-Garcia, Antonio [11 ]
Pollari, Francesco [12 ]
Fischlein, Theodor [12 ]
Budano, Carlo [1 ,2 ]
Montefusco, Antonio [1 ,2 ]
Gallone, Guglielmo [1 ,2 ]
De Filippo, Ovidio [1 ,2 ]
Rinaldi, Mauro [2 ,13 ]
la Torre, Michele [2 ,13 ]
Salizzoni, Stefano [2 ,13 ]
Atzeni, Francesco [2 ,13 ]
Pocar, Marco [2 ,13 ]
Conrotto, Federico [1 ,2 ]
De Ferrari, Gaetano Maria [1 ,2 ]
机构
[1] Citta Salute & Sci Hosp, Div Cardiol Cardiovasc & Thorac Dept, Turin, Italy
[2] Univ Turin, Turin, Italy
[3] Columbia Univ, Med Ctr, Dept Cardiol, Div Cardiol,New York Presbyterian Hosp, New York, NY USA
[4] Univ Catania, CAST Policlin G Rodolico Hosp, Dept Cardiol, Catania, Italy
[5] Laval Univ, Quebec Heart & Lung Inst, Dept Cardiol, Quebec City, PQ, Canada
[6] St Johannes Hosp, Klin Innere Med 1, Dortmund, Germany
[7] Univ Hosp Regensburg, Dept Internal Med 2, Cardiol, Pneumol,Intens Care, Regensburg, Germany
[8] Erasmus MC, Dept Cardiol, Rotterdam, Netherlands
[9] Leiden Univ, Heart Lung Ctr, Dept Cardiol, Med Ctr, Leiden, Netherlands
[10] Brighton & Sussex Univ Hosp NHS Trust, Sussex Cardiac Ctr, Dept Cardiol, Brighton, E Sussex, England
[11] Hosp Virgen de la Victoria, Dept Cardiol, Malaga, Spain
[12] Paracelsus Med Univ, Cardiovasc Ctr, Dept Cardiac Surg, Klinikum Nurnberg, Breslauer Str 201, Nurnberg, Germany
[13] Citta Salute & Sci Hosp, Cardiovasc & Thorac Dept, Div Cardiosurg, Turin, Italy
关键词
Aortic stenosis; Transcatheter aortic valve replacement; Transcatheter aortic valve implantation; Conduction disturbances; Permanent pacemaker; PERMANENT PACEMAKER; CONDUCTION ABNORMALITIES; FOLLOW-UP; REPLACEMENT; IMPACT; STENOSIS; NEED; OUTCOMES; DISTURBANCES; SOCIETY;
D O I
10.1093/ehjqcco/qcaa089
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Permanent pacemaker implantation (PPI) may be required after transcatheter aortic valve implantation (TAVI). Evidence on PPI prediction has largely been gathered from high-risk patients receiving first-generation valve implants. We undertook a meta-analysis of the existing literature to examine the incidence and predictors of PPI after TAVI according to generation of valve, valve type, and surgical risk. Methods and results We made a systematic literature search for studies with >= 100 patients reporting the incidence and adjusted predictors of PPI after TAVI. Subgroup analyses examined these features according to generation of valve, specific valve type, and surgical risk. We obtained data from 43 studies, encompassing 29 113 patients. Permanent pacemaker implantation rates ranged from 6.7% to 39.2% in individual studies with a pooled incidence of 19% (95% CI 16-21). Independent predictors for PPI were age [odds ratio (OR) 1.05, 95% confidence interval (CI) 1.01-1.09], left bundle branch block (LBBB) (OR 1.45, 95% CI 1.12-1.77), right bundle branch block (RBBB) (OR 4.15, 95% CI 3.23-4.88), implantation depth (OR 1.18, 95% CI 1.11-1.26), and self-expanding valve prosthesis (OR 2.99, 95% CI 1.39-4.59). Among subgroups analysed according to valve type, valve generation and surgical risk, independent predictors were RBBB, self-expanding valve type, first-degree atrioventricular block, and implantation depth. Conclusions The principle independent predictors for PPI following TAVI are age, RBBB, LBBB, self-expanding valve type, and valve implantation depth. These characteristics should be taken into account in pre-procedural assessment to reduce PPI rates.
引用
收藏
页码:143 / 153
页数:11
相关论文
共 50 条
  • [41] TRANSCATHETER AORTIC VALVE IMPLANTATION WITH OR WITHOUT PRE-IMPLANTATION BALLOON AORTIC VALVULOPLASTY: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Bagur, Rodrigo
    Kwok, Chun Shing
    Nombela-Franco, Luis
    Ludman, Peter
    de Belder, Mark
    Sponga, Sandro
    Gunning, Mark
    Nolan, James
    Kiaii, Bob
    Diamantouros, Pantelis
    Chu, Michael
    Teefy, Patrick
    Mamas, Mamas A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 411 - 411
  • [42] Protamine Administration and Bleeding Risk Following Transcatheter Aortic Valve Implantation: A Systematic Review and Meta-Analysis
    Kara, Arwi Omar
    Beshr, Mohammed S.
    Alzubi, Alhasan Saleh
    Alansari, Arowahassan Abdulrahman
    Arhaym, Esraa
    Aburawi, Dania Mukhtar
    El Awami, Mostafa
    Shahin, Hatim
    Abdelwahed, Abdelrahman Farag
    Abdulsalam, Anas Atiyah
    Almezghwi, Heyam
    Elhadi, Muhammed
    CIRCULATION, 2024, 150
  • [43] Incidence rate and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis
    Valeria Calvi
    Sergio Conti
    Giusi Paola Pruiti
    Davide Capodanno
    Euglena Puzzangara
    Donatella Tempio
    Angelo Di Grazia
    Gian Paolo Ussia
    Corrado Tamburino
    Journal of Interventional Cardiac Electrophysiology, 2012, 34 : 189 - 195
  • [44] Incidence rate and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis
    Conti, S.
    Pruiti, G. P.
    Capodanno, D.
    Puzzangara, E.
    Di Grazia, A.
    Ussia, G. P.
    Tamburino, C.
    Calvi, V.
    EUROPEAN HEART JOURNAL, 2011, 32 : 940 - 940
  • [45] Dual or Single Antiplatelet Therapy After Transcatheter Aortic Valve Implantation? A Systematic Review and Meta-Analysis
    Vavuranakis, Manolis
    Siasos, Gerasimos
    Zografos, Theodoros
    Oikonomou, Evangelos
    Vrachatis, Dimitris
    Kalogeras, Konstantinos
    Papaioannou, Theodoros
    Kolokathis, Michail-Aggelos
    Moldovan, Carmen
    Tousoulis, Dimitrios
    CURRENT PHARMACEUTICAL DESIGN, 2016, 22 (29) : 4596 - 4603
  • [46] Incidence rate and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis
    Calvi, Valeria
    Conti, Sergio
    Pruiti, Giusi Paola
    Capodanno, Davide
    Puzzangara, Euglena
    Tempio, Donatella
    Di Grazia, Angelo
    Ussia, Gian Paolo
    Tamburino, Corrado
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (02) : 189 - 195
  • [47] Sarcopenia as a predictor of outcome after transcatheter aortic valve implantation: protocol for systematic review and meta-analysis
    Luo, Kai
    Yang, Lei
    Li, Yu
    BMJ OPEN, 2022, 12 (11):
  • [48] Role of the tricuspid regurgitation after mitraclip and transcatheter aortic valve implantation: a systematic review and meta-analysis
    Pavasini, Rita
    Ruggerini, Sara
    Grapsa, Julia
    Biscaglia, Simone
    Tumscitz, Carlo
    Serenelli, Matteo
    Boriani, Giuseppe
    Squeri, Angelo
    Campo, Gianluca
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (06) : 654 - 659
  • [49] Correction: A systematic review and meta-analysis of the cerebrovascular event incidence after transcatheter aortic valve implantation
    Max M. Meertens
    Sascha Macherey
    Sebastiaan Asselberghs
    Samuel Lee
    Jan Hendrik Schipper
    Barend Mees
    Ingo Eitel
    Stephan Baldus
    Christian Frerker
    Tobias Schmidt
    Clinical Research in Cardiology, 2022, 111 : 969 - 970
  • [50] Troponin as a predictor of outcomes in transcatheter aortic valve implantation: systematic review and meta-analysis
    Jacqueline Nguyen Khuong
    Zhengyang Liu
    Ryan Campbell
    Sarah M. Jackson
    Carla Borg Caruana
    Dhruvesh M. Ramson
    Jahan C. Penny-Dimri
    Luke A. Perry
    General Thoracic and Cardiovascular Surgery, 2023, 71 : 12 - 19