Comparative Analysis of Arthroscopic Tight Rope ACL Reconstruction Using four Strand Isolated Semitendinosus Graft and Quadrupled Combined Hamstring Graft

被引:3
|
作者
Kumar, Ramesh [2 ]
Chouhan, Dushyant [1 ]
Narang, Amit [1 ]
Kalra, Mukesh [1 ]
Choudhary, Ranjeet [3 ]
Kumar, Ankush [1 ]
机构
[1] Lady Hardinge Med Coll & Hosp, Dept Orthoped, New Delhi, India
[2] Vardhman Mahavir Med Coll, Dept Orthopaed, New Delhi, India
[3] All India Inst Med Sci, Dept Orthoped, Raipur, Madhya Pradesh, India
来源
关键词
Combined Hamstring graft; Four-strand semitendinosus; Single bundle ACL reconstruction; CRUCIATE LIGAMENT RECONSTRUCTION; FIXATION METHODS; PATELLAR TENDON; ANTERIOR;
D O I
10.22038/ABJS.2021.49619.2463
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Arthroscopic ACL reconstruction using hamstring autograft is a quite a popular surgical procedure. But there is a conflict regarding the use of isolated semitendinosus graft or a combined hamstring graft. We did a comparative analysis of the functional outcome after ACL reconstruction performed with four strand semitendinosus graft and a combined hamstring graft over tightrope. Methods: Two groups of 30 patients each with similar demographic profiles, presenting with symptoms of instability after chronic ACL tear were included. A standard single bundle arthroscopic ACL reconstruction was performed by using four-strand semitendinosus graft in Group A and combined hamstring graft in Group B patients. Clinical and functional outcome analysis was done using quantitative anterior tibial translation measurement and Lysholm score. Results: The mean age of subjects in group A was 29 years and in Group B was 28 years. The semitendinosus graft length was insufficient in 13.33% cases in group A. The improvement in Lysholm score and the decrease in the tibial translation were comparable in both the groups at one year of follow-up. No added comorbidities were noted in additional removal of gracilis tendon in group B patients. Conclusion: Isolated semitendinosus four-strand autograft can be used for arthroscopic single bundle ACL reconstruction when adequate graft length is obtained. However, one should not be hesitant in additional removal of gracilis tendon when needed. In terms of functional outcome and patient satisfaction, both the graft configurations stand the same.
引用
收藏
页码:426 / 431
页数:6
相关论文
共 50 条
  • [31] Are pre-operative anthropometric parameters helpful in predicting length and thickness of quadrupled hamstring graft for ACL reconstruction in adults? A prospective study and literature review
    Saumitra Goyal
    Nadia Matias
    Vivek Pandey
    Kiran Acharya
    International Orthopaedics, 2016, 40 : 173 - 181
  • [32] Knee Hyperextension Greater Than 5° Is a Risk Factor for Failure in ACL Reconstruction Using Hamstring Graft
    Guimaraes, Tales Mollica
    Giglio, Pedro Nogueira
    Sobrado, Marcel Faraco
    Bonadio, Marcelo Batista
    Gobbi, Riccardo Gomes
    Pecora, Jose Ricardo
    Helito, Camilo Partezani
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (11)
  • [33] Outcomes of hamstring graft with preserved tibial insertion for ACL reconstruction: systematic review and meta-analysis
    Nicolas Vari
    Etienne Cavaignac
    Marie Cavaignac
    Émilie Bérard
    Vincent Marot
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 : 67 - 73
  • [34] The Tape Locking Screw technique (TLS): A new ACL reconstruction method using a short hamstring graft
    Collette, M.
    Cassard, X.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (05) : 555 - 559
  • [35] Are pre-operative anthropometric parameters helpful in predicting length and thickness of quadrupled hamstring graft for ACL reconstruction in adults? A prospective study and literature review
    Goyal, Saumitra
    Matias, Nadia
    Pandey, Vivek
    Acharya, Kiran
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (01) : 173 - 181
  • [36] Outcomes of hamstring graft with preserved tibial insertion for ACL reconstruction: systematic review and meta-analysis
    Vari, Nicolas
    Cavaignac, Etienne
    Cavaignac, Marie
    Berard, Emilie
    Marot, Vincent
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (01): : 67 - 73
  • [37] ACL reconstruction using semitendinosus tendon graft retaining the tibial insertion. Preliminary results in rabbits.
    Papachristou, GK
    Nikolaou, VS
    Sourlas, IK
    Konstantina, F
    Lazarettos, IT
    Nicolas, EE
    PROCEEDINGS OF THE THIRD IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2005, : 61 - 66
  • [38] Arthroscopic transtibial single-bundle posterior cruciate ligament reconstruction using patellar tendon graft compared with hamstring tendon graft
    Lin, Yu-Chuan
    Chen, Shen-Kai
    Liu, Teng-Hsiang
    Cheng, Yuh-Min
    Chou, Paul Pei-Hsi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (04) : 523 - 530
  • [39] Arthroscopic transtibial single-bundle posterior cruciate ligament reconstruction using patellar tendon graft compared with hamstring tendon graft
    Yu-Chuan Lin
    Shen-Kai Chen
    Teng-Hsiang Liu
    Yuh-Min Cheng
    Paul Pei-Hsi Chou
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 523 - 530
  • [40] Five-Strand versus Four-Strand Hamstring Tendon Graft Technique for Anterior Cruciate Ligament Reconstruction: A Biomechanical Comparison
    Vaillant, Eric R.
    Parks, Brent G.
    Camire, Lyn M.
    Hinton, Richard Y.
    JOURNAL OF KNEE SURGERY, 2017, 30 (09) : 916 - 919