Effect of respiratory motion on free-breathing 3D stack-of-radial liver R2*relaxometry and improved quantification accuracy using self-gating

被引:25
|
作者
Zhong, Xiaodong [1 ]
Armstrong, Tess [2 ,3 ]
Nickel, Marcel D. [4 ]
Kannengiesser, Stephan Ar [4 ]
Pan, Li [5 ]
Dale, Brian M. [6 ]
Deshpande, Vibhas [7 ]
Kiefer, Berthold [4 ]
Wu, Holden H. [2 ,3 ]
机构
[1] Siemens Healthcare, MR R&D Collaborat, 10945 Le Conte Ave,Suite 3371J, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Phys & Biol Med Interdept Program, Los Angeles, CA 90095 USA
[4] Siemens Healthcare GmbH, MR Applicat Dev, Erlangen, Germany
[5] Siemens Healthcare, MR R&D Collaborat, Baltimore, MD USA
[6] Siemens Healthcare, MR R&D Collaborat, Cary, NC USA
[7] Siemens Healthcare, MR R&D Collaborat, Austin, TX USA
关键词
R-2(*); Dixon; motion compensation; PDFF; respiratory motion; self-gating; HEPATIC FAT; IRON; MRI; WATER;
D O I
10.1002/mrm.28052
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop an accurate free-breathing 3D liver R2* mapping approach and to evaluate it in vivo. Methods A free-breathing multi-echo stack-of-radial sequence was applied in 5 normal subjects and 6 patients at 3 Tesla. Respiratory motion compensation was implemented using the inherent self-gating signal. A breath-hold Cartesian acquisition was the reference standard. Proton density fat fraction and R2* were measured and compared between radial and Cartesian methods using Bland-Altman plots. The normal subject results were fitted to a linear mixed model (P < .05 considered significant). Results Free-breathing stack-of-radial without self-gating exhibited signal attenuation in echo images and artifactually elevated apparent R2* values. In the Bland-Altman plots of normal subjects, compared to breath-hold Cartesian, free-breathing stack-of-radial acquisitions of 22, 30, 36, and 44 slices, had mean R2* differences of 27.4, 19.4, 10.9, and 14.7 s(-1) with 800 radial views, and they had 18.4, 11.9, 9.7, and 27.7 s(-1) with 404 views, which were reduced to 0.4, 0.9, -0.2, and -0.7 s(-1) and to -1.7, -1.9, -2.1, and 0.5 s(-1) with self-gating, respectively. No substantial proton density fat fraction differences were found. The linear mixed model showed free-breathing radial R2* results without self-gating were significantly biased by 17.2 s(-1) averagely (P = .002), which was eliminated with self-gating (P = .930). Proton density fat fraction results were not different (P > .234). For patients, Bland-Altman plots exhibited mean R2* differences of 14.4 and 0.1 s(-1) for free-breathing stack-of-radial without self-gating and with self-gating, respectively, but no substantial proton density fat fraction differences. Conclusion The proposed self-gating method corrects the respiratory motion bias and enables accurate free-breathing stack-of-radial quantification of liver R2*.
引用
收藏
页码:1964 / 1978
页数:15
相关论文
共 45 条
  • [31] Improved free-breathing liver fat and iron quantification using a 2D chemical shift–encoded MRI with flip angle modulation and motion-corrected averaging
    Jitka Starekova
    Ruiyang Zhao
    Timothy J. Colgan
    Kevin M. Johnson
    Jennifer L. Rehm
    Shane A. Wells
    Scott B. Reeder
    Diego Hernando
    European Radiology, 2022, 32 : 5458 - 5467
  • [32] 3D Radial Sampling and 3D Affine Transform-based Respiratory Motion Correction Technique for Free-breathing Whole-Heart Coronary MRA with 100% Imaging Efficiency
    Bhat, Himanshu
    Ge, Lan
    Nielles-Vallespin, Sonia
    Zuehlsdorff, Sven
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) : 1269 - 1277
  • [33] Free-Breathing 3D Imaging of Right Ventricular Structure and Function Using Respiratory and Cardiac Self-Gated Cine MRI
    Zhu, Yanchun
    Liu, Jing
    Weinsaft, Jonathan
    Spincemaille, Pascal
    Nguyen, Thanh D.
    Prince, Martin R.
    Bao, Shanglian
    Xie, Yaoqin
    Wang, Yi
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [34] Improved free-breathing liver fat and iron quantification using a 2D chemical shift-encoded MRI with flip angle modulation and motion-corrected averaging
    Starekova, Jitka
    Zhao, Ruiyang
    Colgan, Timothy J.
    Johnson, Kevin M.
    Rehm, Jennifer L.
    Wells, Shane A.
    Reeder, Scott B.
    Hernando, Diego
    EUROPEAN RADIOLOGY, 2022, 32 (08) : 5458 - 5467
  • [35] Free-Breathing Liver Fat, R2* and B0 Field Mapping Using Multi-Echo Radial FLASH and Regularized Model-Based Reconstruction
    Tan, Zhengguo
    Unterberg-Buchwald, Christina
    Blumenthal, Moritz
    Scholand, Nick
    Schaten, Philip
    Holme, Christian
    Wang, Xiaoqing
    Raddatz, Dirk
    Uecker, Martin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2023, 42 (05) : 1374 - 1387
  • [36] 3D CARDIAC CINE RECONSTRUCTION FROM FREE-BREATHING 2D REAL-TIME IMAGE ACQUISITIONS USING ITERATIVE MOTION CORRECTION
    Jantsch, Martin
    Rueckert, Daniel
    Price, Anthony N.
    Hajnal, Joseph V.
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 812 - 815
  • [37] Free-breathing high isotropic resolution quantitative susceptibility mapping (QSM) of liver using 3D multi-echo UTE cones acquisition and respiratory motion-resolved image reconstruction
    Kang, MungSoo
    Behr, Gerald G.
    Jafari, Ramin
    Gambarin, Maya
    Otazo, Ricardo
    Kee, Youngwook
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (05) : 1844 - 1858
  • [38] Projection-based respiratory-resolved left ventricular volume measurements in patients using free-breathing double golden-angle 3D radial acquisition
    Holst, Karen
    Fyrdahl, Alexander
    Caidahl, Kenneth
    Ugander, Martin
    Sigfridsson, Andreas
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (03) : 331 - 341
  • [39] Projection-based respiratory-resolved left ventricular volume measurements in patients using free-breathing double golden-angle 3D radial acquisition
    Karen Holst
    Alexander Fyrdahl
    Kenneth Caidahl
    Martin Ugander
    Andreas Sigfridsson
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 331 - 341
  • [40] Phase2Phase Respiratory Motion-Resolved Reconstruction of Free-Breathing Magnetic Resonance Imaging Using Deep Learning Without a Ground Truth for Improved Liver Imaging
    Eldeniz, Cihat
    Gan, Weijie
    Chen, Sihao
    Fraum, Tyler J.
    Ludwig, Daniel R.
    Yan, Yan
    Liu, Jiaming
    Vahle, Thomas
    Krishnamurthy, Uday
    Kamilov, Ulugbek S.
    An, Hongyu
    INVESTIGATIVE RADIOLOGY, 2021, 56 (12) : 809 - 819