Development of radiodetection systems towards miniaturised quality control of PET and SPECT radiopharmaceuticals

被引:23
|
作者
Taggart, Matthew P. [1 ]
Tarn, Mark D. [2 ,3 ]
Esfahani, Mohammad M. N. [4 ]
Schofield, Daniel M. [5 ]
Brown, Nathaniel J. [4 ]
Archibald, Stephen J. [2 ,3 ]
Deakin, Tom [1 ,5 ]
Pamme, Nicole [3 ]
Thompson, Lee F. [1 ]
机构
[1] Univ Sheffield, Dept Phys & Astron, Hounsfield Rd, Sheffield S3 7RH, S Yorkshire, England
[2] Univ Hull, Positron Emiss Tomog Res Ctr, Kingston Upon Hull HU6 7RX, N Humberside, England
[3] Univ Hull, Dept Chem, Cottingham Rd, Kingston Upon Hull HU6 7RX, N Humberside, England
[4] Univ Hull, Sch Engn, Cottingham Rd, Kingston Upon Hull HU6 7RX, N Humberside, England
[5] LabLog Syst Ltd, Paradigm House,3 Melbourne Ave, Sheffield S10 2QJ, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
DOSE-ON-DEMAND; PROBE DEVELOPMENT; TRACER; CHIP; MICROFLUIDICS; CELL; RADIOTRACERS; DERIVATIVES; FUTURE;
D O I
10.1039/c6lc00099a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The ability to detect radiation in microfluidic devices is important for the on-chip analysis of radiopharmaceuticals, but previously reported systems have largely suffered from various limitations including cost, complexity of fabrication, and insufficient sensitivity and/or speed. Here, we present the use of sensitive, low cost, small-sized, commercially available silicon photomultipliers (SiPMs) for the detection of radioactivity inside microfluidic channels fabricated from a range of conventional microfluidic chip substrates. We demonstrate the effects of chip material and thickness on the detection of the positron-emitting isotope, [F-18]fluoride, and find that, while the SiPMs are light sensors, they are able to detect radiation even through opaque chip materials via direct positron and gamma (gamma) ray interaction. Finally, we employed the SiPM platform for analysis of the PET (positron emission tomography) radiotracers 2-[F-18]fluoro-2-deoxy-D-glucose ([F-18]FDG) and [Ga-68]gallium-citrate, and highlight the ability to detect the. ray emitting SPECT (single photon emission computed tomography) radiotracer, [Tc-99m] pertechnetate.
引用
收藏
页码:1605 / 1616
页数:12
相关论文
共 50 条
  • [31] Comparison of quality control between PET/MRI and PET/CT systems using NEMA tests
    Abuqbeitah, M.
    Demir, M.
    Yeyin, N.
    Toklu, T.
    Sezgin, S.
    Cetin, H.
    Sonmezoglu, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S340 - S341
  • [32] Preclinical SPECT and PET: Joint EANM and ESMI procedure guideline for implementing an efficient quality control programme
    Vanhove, Christian
    Koole, Michel
    Costa, Pedro Fragoso
    Schottelius, Margret
    Mannheim, Julia
    Kuntner, Claudia
    Warnock, Geoff
    Mcdougald, Wendy
    Tavares, Adriana
    Bernsen, Monique
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 (13) : 3822 - 3839
  • [33] Evaluation of an unshielded luminescence flow-through radio-HPLC detector for LC quality control and preparation of PET radiopharmaceuticals
    Thonon, David
    Kaisin, Geoffroy
    Henrottin, Jean
    Aerts, Joel
    Van Malderen, Hans
    Luxen, Andre
    APPLIED RADIATION AND ISOTOPES, 2013, 73 : 84 - 89
  • [34] Towards quality-of-service control of networked control systems: A switched time delay systems approach
    Chen, Chih-Chung
    Hirche, Sandra
    Buss, Martin
    PROCEEDINGS OF THE 2006 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, VOLS 1-4, 2006, : 778 - 783
  • [35] A software quality strategy for the development of automatic control systems
    Lin, KS
    McEwan, W
    Liechti, JH
    INTERNATIONAL JOURNAL OF COMPUTER APPLICATIONS IN TECHNOLOGY, 1999, 12 (2-5) : 131 - 140
  • [36] QUALITY-CONTROL FOR INFORMATION-SYSTEMS DEVELOPMENT
    CEDDIA, D
    SOFTWARE ENGINEERING EDUCATION, 1993, 40 : 135 - 141
  • [37] Problems of the development and quality control of large software systems
    V. V. Lipaev
    Programming and Computer Software, 2005, 31 : 47 - 49
  • [38] Problems of the development and quality control of large software systems
    Lipaev, VV
    PROGRAMMING AND COMPUTER SOFTWARE, 2005, 31 (01) : 47 - 49
  • [39] Evaluation of alternative rapid thin layer chromatography systems for quality control of technetium-99m radiopharmaceuticals
    Mang'era, Kennedy
    Wong, Derek
    Douglas, David
    Franz, Kellie
    Biru, Taddese
    APPLIED RADIATION AND ISOTOPES, 2014, 86 : 57 - 62
  • [40] Taking the perfect nuclear image: Quality control, acquisition, and processing techniques for cardiac SPECT, PET, and hybrid imaging
    Case, James A.
    Bateman, Timothy M.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (05) : 891 - 907