Audit of double-lumen endobronchial intubation

被引:19
|
作者
Seymour, AH [1 ]
Prasad, B [1 ]
McKenzie, RJ [1 ]
机构
[1] Birmingham Heartlands Hosp, Dept Anaesthet, Birmingham B9 5SS, W Midlands, England
关键词
anaesthetic techniques; regional; one lung; thoracic; anaesthetics gases; nitrous oxide; antagonists muscarini; glycopyrrolate; equipment; double lumen tubes; parasympathetic nervous system; atropine;
D O I
10.1093/bja/aeh229
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Many technical variations are possible in the placing and management of a double-lumen tube (DLT). We surveyed our practice to relate these variations to the course of the anaesthetic. Methods. We used a questionnaire to obtain details of technique in 506 consecutive double lumen intubations. The details were related to the incidence of secretions, tube displacement, and decreases of oxygen saturation (<88%) during one lung anaesthesia (OLA). Results. Robertshaw tubes were used for 482 of the 506 intubations. During OLA there were 48 instances of desaturation (<88%), 19 cases of upper lobe obstruction, 15 of carinal obstruction, 16 of isolation failure, eight of excessive secretions (none of whom had received an antisialogogue; P<0.01) and 12 miscellaneous events. The experience of the anaesthetist or use of a fibre-optic bronchoscope did not affect these events. Air was of no advantage as a maintenance gas. Atropine 400-600 mug appeared to prevent desaturation on OLA (P<0.05) but glycopyrrolate 200 mug did not. Conclusion. Most factors had little effect on the progress of the anaesthetic, but an antimuscarinic usefully reduced secretions, and atropine (but not glycopyrrolate) was associated with less desaturation during OLA.
引用
收藏
页码:525 / 527
页数:3
相关论文
共 50 条
  • [21] A randomised controlled trial comparing the GlideScope® and the Macintosh laryngoscope for double-lumen endobronchial intubation
    Russell, T.
    Slinger, P.
    Roscoe, A.
    McRae, K.
    Van Rensburg, A.
    ANAESTHESIA, 2013, 68 (12) : 1253 - 1258
  • [22] A Randomized Controlled Study of the Use of Video Double-Lumen Endobronchial Tubes Versus Double-Lumen Endobronchial Tubes in Thoracic
    Heir, Jagtar Singh
    Guo, Shu-Lin
    Purugganan, Ronaldo
    Jackson, Tim A.
    Sekhon, Anupamjeet Kaur
    Mirza, Kazim
    Lasala, Javier
    Feng, Lei
    Cata, Juan P.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (01) : 267 - 274
  • [23] DOUBLE-LUMEN ENDOBRONCHIAL TUBES FOR PATIENTS WITH TRACHEOSTOMIES
    COE, VL
    BRODSKY, JB
    MARK, JBD
    ANESTHESIA AND ANALGESIA, 1984, 63 (09): : 882 - 882
  • [24] Cardiovascular and arousal responses to single-lumen endotracheal and double-lumen endobronchial intubation in the normotensive and hypertensive elderly
    Yoo, Kyung Yeon
    Jeong, Cheol Won
    Kim, Woong Mo
    Lee, Hyung Kon
    Jeong, Seongtae
    Kim, Seok Jae
    Bae, Hong Beum
    Lim, Dong Yun
    Chung, Sung Su
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2011, 60 (02) : 90 - 97
  • [25] A CATHETER MOUNT FOR DOUBLE-LUMEN ENDOBRONCHIAL TUBES
    WELSH, BE
    CONN, AW
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1970, 17 (02) : 183 - &
  • [26] COMPARISON OF THE RESISTANCES OF DOUBLE-LUMEN ENDOBRONCHIAL TUBES
    HAMMOND, JE
    WRIGHT, DJ
    BRITISH JOURNAL OF ANAESTHESIA, 1984, 56 (03) : 299 - 302
  • [27] Positioning the double-lumen endobronchial tube -: Reply
    Fortier, G
    Bussières, J
    Coté, D
    Bergeron, C
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2002, 49 (05): : 527 - 527
  • [28] LOW RESISTANCE DOUBLE-LUMEN ENDOBRONCHIAL TUBES
    ROBERTSHAW, FL
    BRITISH JOURNAL OF ANAESTHESIA, 1962, 34 (08) : 576 - &
  • [29] Double-Lumen Endobronchial Tubes and Bronchial Blockers
    Alston, R. Peter
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 38 (01) : 341 - 342
  • [30] ENDOBRONCHIAL CUFF PRESSURES OF DOUBLE-LUMEN TUBES
    MAGEE, PT
    ANESTHESIA AND ANALGESIA, 1991, 72 (02): : 265 - 266