Current source design for electrical impedance tomography

被引:105
|
作者
Ross, AS [1 ]
Saulnier, GJ
Newell, JC
Isaacson, D
机构
[1] Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY 12180 USA
[2] Rensselaer Polytech Inst, Dept Elect & Comp Syst Engn, Troy, NY 12180 USA
[3] Rensselaer Polytech Inst, Dept Math Sci, Troy, NY 12180 USA
关键词
electrical impedance imaging; electrical impedance tomography; current source; generalized impedance converter;
D O I
10.1088/0967-3334/24/2/361
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Questions regarding the feasibility of using electrical impedance tomography (EIT) to detect breast cancer may be answered by building a sufficiently precise multiple frequency EIT instrument. Current sources are desirable for this application, yet no current source designs have been reported that have the required precision at the multiple frequencies needed. We have designed an EIT current source using an enhanced Howland topology in parallel with a generalized impedance converter (GIC). This combination allows for nearly independent adjustment of output resistance and output capacitance, resulting in simulated output impedances in excess of 2 GOmega between 100 Hz and I MHz. In this paper, the theoretical operation of this current source is explained, and experimental results demonstrate the feasibility of creating a high precision, multiple frequency, capacitance compensated current source for EIT applications.
引用
收藏
页码:509 / 516
页数:8
相关论文
共 50 条
  • [31] A CURRENT INJECTING DEVICE FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    BLAD, B
    LINDSTROM, K
    BERTENSTAM, L
    PERSSON, BRR
    HOLMER, NG
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 : A69 - A77
  • [32] Comparison of applied and induced current electrical impedance tomography
    Tanguay, Louis-Francois
    Gagnon, Herve
    Guardo, Robert
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (09) : 1643 - 1649
  • [33] ELECTRICAL-IMPEDANCE TOMOGRAPHY - A REVIEW OF CURRENT LITERATURE
    JONGSCHAAP, HCN
    WYTCH, R
    HUTCHISON, JMS
    KULKARNI, V
    EUROPEAN JOURNAL OF RADIOLOGY, 1994, 18 (03) : 165 - 174
  • [34] Comparing Between Three Current Source Circuits for Using in Bio Electrical Impedance Design
    Ar-Rawi, A. H.
    Moghavvemi, M.
    Wan-Ibrahim, W. M. A.
    2009 INTERNATIONAL CONFERENCE FOR TECHNICAL POSTGRADUATES (TECHPOS 2009), 2009, : 19 - +
  • [35] Simulation of a Current Source with a Cole-Cole Load for multi-frequency Electrical Impedance Tomography
    Santos, Susana Aguiar
    Schlebusch, Thomas
    Leonhardt, Steffen
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 6445 - 6448
  • [36] Voltage Controlled Current Source (VCCS) for Electrical Impedance Tomography (EIT) Measurements in the α and β Dispersion Frequency Ranges
    Gutierrez Gnecchi, Jose Antonio
    2010 IEEE ELECTRONICS, ROBOTICS AND AUTOMOTIVE MECHANICS CONFERENCE (CERMA 2010), 2010, : 677 - 681
  • [37] Design of A Current Source for Bioelectrical Impedance Measurement
    Wang Ke-ning
    Zhao Heng
    Wang Wei
    MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 387 - 391
  • [38] A Wearable Open-Source electrical impedance tomography device
    Creegan, Andrew
    Bradfield, Joshua
    Richardson, Samuel
    Johns, Llewellyn Sims
    Burrowes, Kelly
    Kumar, Haribalan
    Nielsen, Poul M. F.
    Tawhai, Merryn H.
    HARDWAREX, 2024, 18
  • [39] Digital Quadrature Demodulate Design for Electrical Impedance Tomography
    Wu You
    Zhao Dechun
    Sha Hong
    Gan Yu
    2009 INTERNATIONAL CONFERENCE ON FUTURE BIOMEDICAL INFORMATION ENGINEERING (FBIE 2009), 2009, : 406 - +
  • [40] Design and Development of a Portable Electrical Impedance Tomography System
    Xu, Jiahao
    Lu, Jiewei
    Zhang, Song
    Yu, Ningbo
    Han, Jianda