Breathhold 19F-magnetic resonance imaging of lung ventilation using SF6 gas.

被引:25
|
作者
Schreiber, WG
Markstaller, K
Weiler, N
Eberle, B
Laukemper-Ostendorf, S
Scholz, A
Bürger, K
Thelen, M
Kauczor, HU
机构
[1] Univ Mainz, Klin & Poliklin Radiol, D-6500 Mainz, Germany
[2] Univ Mainz, Anasthesiol Klin, D-6500 Mainz, Germany
关键词
lung ventilation; SF6; magnetic resonance; F-19; ultrafast imaging; animal study;
D O I
10.1055/s-2000-3750
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Development of a method to analyze lung ventilation by F-19-magnetic resonance imaging (MRI) of inspired SF, gas during breathhold. Material and Methods: Measurements were performed with a Siemens Magnetom Vision 1.5T scanner using the conventional gradient overdrive. Coronal images of the lung were acquired using ultrafast gradient-echo pulse sequences with TR/TE/alpha=1.4ms/ 0.48 ms/40 degrees without slice selection. With NEX = 200 averages and MA=32x64 raw data matrix, the acquisition time was 9 s/image. Higher spatial resolution of 4.7 x 6.3 x 15 mm(3) was obtained with a three-dimensional pulse sequence (TR/TE/ alpha=1.6ms/0.48ms/65 degrees, NEX=20) running for 49 s. Measurements wer performed in three anesthetized and ventilated pigs (18 kg). Results: A nearly linear relation between SF6 concentration and F-19 signal intensity was observed. The signal-to-noise ratio in images obtained without slice selection was 30.9, with slice selection it was 14.9. No differences between SF6 distribution to both lungs were observed in the animals. Conclusion: Breathhold MRI of SF6 gas distribution in the lung was demonstrated for the first time. The low spin-density was compensated for by highly repetitive signal averaging. Breathhold F-19-MR imaging of ventilated airspaces to assess SF6 distribution in the human lung appears to be an interesting new method, which can be implemented with little technical efforts, and does not rely on radioactive isotopes.
引用
收藏
页码:500 / 503
页数:4
相关论文
共 50 条
  • [21] High-resolution three-dimensional 19F-magnetic resonance imaging of rat lung in situ: evaluation of airway strain in the perfluorocarbon-filled lung
    Weigel, Julia K.
    Steinmann, Daniel
    Emerich, Philipp
    Stahl, Claudius A.
    v. Elverfeldt, Dominik
    Guttmann, Josef
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (02) : 251 - 262
  • [22] Cargo-influences on the biodistribution of hollow mesoporous silica nanoparticles as studied by quantitative 19F-magnetic resonance imaging
    Pochert, Alexander
    Vernikouskaya, Ina
    Pascher, Felix
    Rasche, Volker
    Linden, Mika
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2017, 488 : 1 - 9
  • [23] Visualization of Abscess Formation in a Murine Thigh Infection Model of Staphylococcus aureus by 19F-Magnetic Resonance Imaging (MRI)
    Hertlein, Tobias
    Sturm, Volker
    Kircher, Stefan
    Basse-Luesebrink, Thomas
    Haddad, Daniel
    Ohlsen, Knut
    Jakob, Peter
    PLOS ONE, 2011, 6 (03):
  • [24] Volume of rat lungs measured throughout the respiratory cycle using 19F NMR of the inert gas SF6
    Kuethe, DO
    Behr, VC
    Begay, S
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) : 547 - 549
  • [25] Regional Lung Ventilation Analysis Using Temporally Resolved Magnetic Resonance Imaging
    Kolb, Christoph
    Wetscherek, Andreas
    Buzan, Maria Teodora
    Werner, Rene
    Rank, Christopher M.
    Kachelriess, Marc
    Kreuter, Michael
    Dinkel, Julien
    Heussel, Claus Peter
    Maier-Hein, Klaus
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) : 899 - 906
  • [26] Fluorine Meets Amine: Reducing Microenvironment-Induced Amino-Activatable Nanoprobes for 19F-Magnetic Resonance Imaging of Biothiols
    Huang, Pingsheng
    Guo, Weisheng
    Yang, Guang
    Song, Huijuan
    Wang, Yuqing
    Wang, Chun
    Kong, Deling
    Wang, Weiwei
    ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (22) : 18532 - 18542
  • [27] Current Status of Lung Ventilation Imaging with Magnetic Resonance Ventilation Scanning Using Aerosolized Contrast Agents
    Das, Marco
    Guenther, Rolf W.
    Haage, Patrick
    CURRENT RESPIRATORY MEDICINE REVIEWS, 2008, 4 (01) : 19 - 22
  • [28] Silicon etch using SF6/C4F8/Ar gas mixtures
    Bates, Robert L.
    Thamban, P. L. Stephan
    Goeckner, Matthew J.
    Overzet, Lawrence. J.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2014, 32 (04):
  • [29] Simultaneous magnetic resonance imaging of ventilation distribution and gas uptake in the human lung using hyperpolarized xenon-129
    Mugler, John P., III
    Altes, Talissa A.
    Ruset, Iulian C.
    Dregely, Isabel M.
    Mata, Jaime F.
    Miller, G. Wilson
    Ketel, Stephen
    Ketel, Jeffrey
    Hersman, F. William
    Ruppert, Kai
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (50) : 21707 - 21712
  • [30] Amyloid imaging using fluorine-19 magnetic resonance imaging (19F-MRI)
    Tooyama, Ikuo
    Yanagisawa, Daijiro
    Taguchi, Hiroyasu
    Kato, Tomoko
    Hirao, Koichi
    Shirai, Nobuaki
    Sogabe, Takayuki
    Ibrahim, Nor Faeizah
    Inubushi, Toshiro
    Morikawa, Shigehiro
    AGEING RESEARCH REVIEWS, 2016, 30 : 85 - 94