Development of Modified SERVQUAL-MCDM Model for Quality Determination in Reverse Logistics

被引:25
|
作者
Stevic, Zeljko [1 ]
Tanackov, Ilija [2 ]
Puska, Adis [3 ]
Jovanov, Goran [4 ]
Vasiljevic, Jovica [5 ]
Lojanicic, Darko [6 ]
机构
[1] Univ East Sarajevo, Fac Transport & Traff Engn Doboj, Vojvode Misica 52, Doboj 74000, Bosnia & Herceg
[2] Univ Novi Sad, Fac Tech Sci, Trg Dositeja Obradovica 6, Novi Sad 21000, Serbia
[3] Govt Brcko Dist B&H, Bulevara Mira 1, Brcko 76100, Bosnia & Herceg
[4] Univ Criminal Invest & Police Studies, Dept Forens, Cara Dusana 196, Belgrade 11080, Serbia
[5] City Belgrade, State Secretary Publ Transport, 27 Marta 43-45, Belgrade 11000, Serbia
[6] MB Univ, Fac Business & Law, Knez Mihajlova 33, Belgrade 11000, Serbia
关键词
quality; reverse logistics; sustainability; SERVQUAL model; waste management; Signum test; FUCOM; SERVICE QUALITY; SUPPLY CHAIN; MANAGEMENT; TRANSPORT; SELECTION; CRITERIA; GAPS;
D O I
10.3390/su13105734
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To run a business successfully, quality determination and customer relations are very important factors. Therefore, it is necessary to measure quality and identify critical points of business. In this paper, an original integrated model for measuring the service quality of reverse logistics (RL) was developed for the company Komunalac Teslic, which was used as an example. The Delphi and Full Consistency Method (FUCOM) was applied to determine the significance of the quality dimensions, while a modified SERVQUAL (SQ) model was used to measure the service quality of the logistics. An original SQ questionnaire was formed with a total of 21 statements that were arranged in five standard dimensions. Examining the reliability of the questionnaire for quality dimensions using the Cronbach Alpha coefficient, it was found that the measurement scales for dimensions are appropriate in terms of user expectations, while in terms of quality perception there is no measurement scale for the empathy dimension. An extensive statistical analysis was then performed to verify the results. A Signum test was applied to identify the relationship between the responses in terms of expectations and perceptions, i.e., to examine their differences. The findings obtained by this research show that the expectations were higher than the perceived quality of the services and that there was a significant statistical difference for 12 of the SQ statements. For two statements, there was a significant statistical difference in favor of perceived quality compared to expectations. Based on the results obtained, the company must improve its services in order for service quality to be at a satisfactory level.
引用
收藏
页数:17
相关论文
共 32 条
  • [21] DETERMINATION OF FLUORIDE CONTENT IN DRINKING-WATER AND DEVELOPMENT OF A MODEL IN RELATION TO SOME WATER-QUALITY PARAMETERS
    MOHAN, SV
    NITHILA, P
    REDDY, SJ
    FRESENIUS ENVIRONMENTAL BULLETIN, 1995, 4 (05): : 297 - 302
  • [22] Implementation of Quality by Design Approaches for Development and Validation of Reverse-Phase High-Performance Liquid Chromatography Assay Method for Determination of Glycyrrhizin in Nanoformulation
    Halder, Jitu
    Saha, Ivy
    Rajwar, Tushar Kanti
    Kar, Biswakanth
    Ghosh, Goutam
    Rath, Goutam
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2024, 22 (01) : 28 - 39
  • [23] High-Quality Development of Science and Technology Finance and Logistics Industry in the Yangtze River Economic Belt: Coupling Analysis Based on Deep Learning Model
    Li, Lingrui
    Huang, Xianjun
    Liu, Pengfei
    COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2022, 2022
  • [24] Analytical Quality by Design-Compliant Development of a Cyclodextrin-Modified Micellar ElectroKinetic Chromatography Method for the Determination of Trimecaine and Its Impurities
    Marzullo, Luca
    Gotti, Roberto
    Orlandini, Serena
    Slavickova, Patricie
    Jires, Jakub
    Zapadlo, Michal
    Dousa, Michal
    Nekvapilova, Pavla
    Rezanka, Pavel
    Furlanetto, Sandra
    MOLECULES, 2023, 28 (12):
  • [25] Quality by Design approach in the development of a solvent-modified micellar electrokinetic chromatography method: Finding the design space for the determination of amitriptyline and its impurities
    Furlanetto, S.
    Orlandini, S.
    Pasquini, B.
    Del Bubba, M.
    Pinzauti, S.
    ANALYTICA CHIMICA ACTA, 2013, 802 : 113 - 124
  • [26] A proposed adaptation of the European Foundation for Quality Management Excellence Model to physical activity programmes for the elderly - development of a quality self-assessment tool using a modified Delphi process
    Marques, Ana I.
    Santos, Leonel
    Soares, Pedro
    Santos, Rute
    Oliveira-Tavares, Antonio
    Mota, Jorge
    Carvalho, Joana
    INTERNATIONAL JOURNAL OF BEHAVIORAL NUTRITION AND PHYSICAL ACTIVITY, 2011, 8
  • [27] A proposed adaptation of the European Foundation for Quality Management Excellence Model to physical activity programmes for the elderly - development of a quality self-assessment tool using a modified Delphi process
    Ana I Marques
    Leonel Santos
    Pedro Soares
    Rute Santos
    António Oliveira-Tavares
    Jorge Mota
    Joana Carvalho
    International Journal of Behavioral Nutrition and Physical Activity, 8
  • [28] Development of a national quality framework for palliative care in a mixed generalist and specialist care model: A whole-sector approach and a modified Delphi technique
    Boddaert, Manon S.
    Douma, Joep
    Dijxhoorn, Anne-Floor Q.
    Heman, Rene A. C. L.
    van der Rijt, Carin C. D.
    Teunissen, Saskia S. C. M.
    Huijgens, Peter C.
    Vissers, Kris C. P.
    PLOS ONE, 2022, 17 (03):
  • [29] Reverse Phase-High-Performance Liquid Chromatography (RP-HPLC) Method Development and Validation Using Analytical Quality-by-Design Approach for Determination of Isoliquiritigenin in Bulk and Biological Sample
    Nihal, P. Mohamed
    Mohapatra, Debasish
    Manir, Alam Mohd Adil Alam
    Harish, Vancha
    Singh, Sachin Kumar
    Lad, Sakshi Upendra
    Sutrapu, Srinivas
    Saini, Sumant
    Mohd, Sharfuddin
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2024, 22 (08) : 409 - 424
  • [30] Development of a robust and reliable reverse-phase high-performance liquid chromatography (RP-HPLC) method using analytical quality by design principles for the accurate determination of esculin in its bulk form
    Sarvesh Patil
    Anjana Adhyapak
    Priya Shetti
    Rohan Gurao
    Future Journal of Pharmaceutical Sciences, 9