Body-mounted robotic assistant for MRI-guided low back pain injection

被引:24
|
作者
Li, Gang [1 ]
Patel, Niravkumar A. [1 ]
Hagemeister, Jan [1 ]
Yan, Jiawen [1 ]
Wu, Di [1 ]
Sharma, Karun [2 ]
Cleary, Kevin [2 ]
Iordachita, Iulian [1 ]
机构
[1] Johns Hopkins Univ, LCSR, Baltimore, MD 21218 USA
[2] Childrens Natl Hlth Syst, Sheikh Zayed Inst Pediat Surg Innovat, Washington, DC USA
关键词
MRI-guided robot; Body-mounted robot; Pain injection; Image-guided therapy; FEASIBILITY; ACCURACY; DESIGN; BIOPSY; SYSTEM;
D O I
10.1007/s11548-019-02080-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose This paper presents the development of a body-mounted robotic assistant for magnetic resonance imaging (MRI)-guided low back pain injection. Our goal was to eliminate the radiation exposure of traditional X-ray guided procedures while enabling the exquisite image quality available under MRI. The robot is designed with a compact and lightweight profile that can be mounted directly on the patient's lower back via straps, thus minimizing the effect of patient motion by moving along with the patient. The robot was built with MR-conditional materials and actuated with piezoelectric motors so it can operate inside the MRI scanner bore during imaging and therefore streamline the clinical workflow by utilizing intraoperative MR images. Methods The robot is designed with a four degrees of freedom parallel mechanism, stacking two identical Cartesian stages, to align the needle under intraoperative MRI-guidance. The system targeting accuracy was first evaluated in free space with an optical tracking system, and further assessed with a phantom study under live MRI-guidance. Qualitative imaging quality evaluation was performed on a human volunteer to assess the image quality degradation caused by the robotic assistant. Results Free space positioning accuracy study demonstrated that the mean error of the tip position to be 0.51 +/- 0.27 mm and needle angle to be 0.70 degrees +/- 0.38 degrees. MRI-guided phantom study indicated the mean errors of the target to be 1.70 +/- 0.21 mm, entry point to be 1.53 +/- 0.19 mm, and needle angle to be 0.66 degrees +/- 0.43 degrees. Qualitative imaging quality evaluation validated that the image degradation caused by the robotic assistant in the lumbar spine anatomy is negligible. Conclusions The study demonstrates that the proposed body-mounted robotic system is able to perform MRI-guided low back injection in a phantom study with sufficient accuracy and with minimal visible image degradation that should not affect the procedure.
引用
收藏
页码:321 / 331
页数:11
相关论文
共 50 条
  • [1] Body-mounted robotic assistant for MRI-guided low back pain injection
    Gang Li
    Niravkumar A. Patel
    Jan Hagemeister
    Jiawen Yan
    Di Wu
    Karun Sharma
    Kevin Cleary
    Iulian Iordachita
    International Journal of Computer Assisted Radiology and Surgery, 2020, 15 : 321 - 331
  • [2] A Fully Actuated Body-Mounted Robotic Assistant for MRI-Guided Low Back Pain Injection
    Li, Gang
    Patel, Niravkumar A.
    Liu, Weiqiang
    Wu, Di
    Sharma, Karun
    Cleary, Kevin
    Fritz, Jan
    Iordachita, Iulian
    2020 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2020, : 5495 - 5501
  • [3] Fully Actuated Body-Mounted Robotic System for MRI-Guided Lower Back Pain Injections: Initial Phantom and Cadaver Studies
    Li, Gang
    Patel, Niravkumar A.
    Wang, Yanzhou
    Dumoulin, Charles
    Loew, Wolfgang
    Loparo, Olivia
    Schneider, Katherine
    Sharma, Karun
    Cleary, Kevin
    Fritz, Jan
    Iordachita, Iulian
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2020, 5 (04): : 5245 - 5251
  • [4] A body-mounted device for MRI-guided spinal therapy
    Squires, Alexander
    Hovet, Sierra
    Li, Rui
    Oshinski, John
    Ho Tse, Zion Tsz
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2021, 17 (02):
  • [5] MRI-guided lumbar spinal injections with body-mounted robotic system: cadaver studies
    Li, Gang
    Patel, Niravkumar A.
    Melzer, Andreas
    Sharma, Karun
    Iordachita, Iulian
    Cleary, Kevin
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2022, 31 (02) : 297 - 305
  • [6] Body-Mounted Robotic System for MRI-Guided Shoulder Arthrography: Cadaver and Clinical Workflow Studies
    Patel, Niravkumar
    Yan, Jiawen
    Li, Gang
    Monfaredi, Reza
    Priba, Lukasz
    Donald-Simpson, Helen
    Joy, Joyce
    Dennison, Andrew
    Melzer, Andreas
    Sharma, Karun
    Iordachita, Iulian
    Cleary, Kevin
    FRONTIERS IN ROBOTICS AND AI, 2021, 8
  • [7] Simulated accuracy assessment of small footprint body-mounted probe alignment device for MRI-guided cryotherapy of abdominal lesions
    Shono, Naoyuki
    Ninni, Brian
    King, Franklin
    Kato, Takahisa
    Tokuda, Junichi
    Fujimoto, Takahiro
    Tuncali, Kemal
    Hata, Nobuhiko
    MEDICAL PHYSICS, 2020, 47 (06) : 2337 - 2349
  • [8] A Fully Actuated Robotic Assistant for MRI-Guided Prostate Biopsy and Brachytherapy
    Li, Gang
    Su, Hao
    Shang, Weijian
    Tokuda, Junichi
    Hata, Nobuhiko
    Tempany, Clare M.
    Fischer, Gregory S.
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [9] Body-mounted robotic instrument guide for age-guided cryotherapy of renal cancer
    Hata, Nobuhiko
    Song, Sang-Eun
    Olubiyi, Olutayo
    Arimitsu, Yasumichi
    Fujimoto, Kosuke
    Kato, Takahisa
    Tuncali, Kemal
    Tani, Soichiro
    Tokuda, Junichi
    MEDICAL PHYSICS, 2016, 43 (02) : 843 - 853
  • [10] Body-Mounted Robotics for Interventional MRI Procedures
    Li, Gang
    Patel, Niravkumar A.
    Sharma, Karun
    Monfaredi, Reza
    Dumoulin, Charles
    Fritz, Jan
    Iordachita, Iulian
    Cleary, Kevin
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2020, 2 (04): : 557 - 560