摘要
The paper focuses the attention on the comparison of two approaches for power quality assessment in the electric grid. Both approaches are suitable for investigating the harmonic pollution source and discovering if the harmonic source comes from the customer or the utility grid. The two approaches have the same purpose but they are deeply different. The first approach is based on the knowledge of the customer and utility equivalent impedance while the second is based on single point measurement at point of common coupling PCC. In this paper, the advantages and drawbacks of the two approaches are investigated also supported by a case study.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] On the assessment of dose proportionality: A comparison of two slope approaches
    Cheng, Bin
    Chow, Shein-Chung
    Su, Wei-Lun
    JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2006, 16 (03) : 385 - 392
  • [22] Engineering ethical curricula: Assessment and comparison of two approaches
    Drake, MJ
    Griffin, PM
    Kirkman, R
    Swann, JL
    JOURNAL OF ENGINEERING EDUCATION, 2005, 94 (02) : 223 - 231
  • [23] Influence of Instrument Transformers on Harmonic Distortion Assessment
    Pfajfar, T.
    Meyer, J.
    Schegner, P.
    Papic, I.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [24] Harmonic Distortion Assessment and Minimization for Railway Systems
    Saied, Mohamed
    Al-Shaher, Meshal
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2009, 37 (08) : 832 - 846
  • [25] Development and performance comparison of two different approaches for stabilizing a harmonic mode-locked fiber laser at 40 GHz
    Bouchard, Line
    Ponomarev, Evgueni A.
    Yang, Shiquan
    Bao, Xiaoyi
    APPLIED OPTICS, 2006, 45 (16) : 3826 - 3830
  • [26] Modeling approaches of harmonic sources in power system
    Zheng, Lian-Qing
    Wu, Ping
    Li, Kun
    Dianwang Jishu/Power System Technology, 2010, 34 (08): : 41 - 45
  • [27] Harmonic assessment-based adjusted current total harmonic distortion
    Aleem, Shady H. E. Abdel
    Ibrahim, Ahmed M.
    Zobaa, Ahmed F.
    JOURNAL OF ENGINEERING-JOE, 2016,
  • [28] Comparison of two numerical approaches for natural convection in cavities with energy sources
    Gibanov, N. S.
    Miroshnichenko, I., V
    Sheremet, M. A.
    XXXV SIBERIAN THERMOPHYSICAL SEMINAR, 2019, 2019, 1382
  • [29] PREDICTING VOLTAGE DISTORTION IN A SYSTEM WITH MULTIPLE RANDOM HARMONIC SOURCES
    KAPRIELIAN, SR
    EMANUEL, AE
    DWYER, RV
    MEHTA, H
    IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (03) : 1632 - 1638
  • [30] Assessment and comparison of different approaches for mask write time reduction
    Elayat, A.
    Lin, T.
    Sahouria, E.
    Schulze, S. F.
    PHOTOMASK TECHNOLOGY 2011, 2011, 8166