Error Correction Method for Smart Energy Meter Field Calibration System under Non-standard Conditions

被引:0
|
作者
Tan Hengyu [1 ]
Yao Hejun [1 ]
Huang Yan [1 ]
Wang Huanning [1 ]
Zhao Zhihua [1 ]
Liu Yuan [1 ]
机构
[1] Beijing Inst Metrol, Beijing, Peoples R China
来源
2020 THE 4TH INTERNATIONAL CONFERENCE ON SMART GRID AND SMART CITIES (ICSGSC 2020) | 2020年
关键词
smart energy meters; field calibrator; measurement; error correction; data surface;
D O I
10.1109/icsgsc50906.2020.9248566
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Smart energy meters have been widely used in the smart grid of various countries, but the current measurement methods of smart energy meters can not solve the traceability problem under the actual load current and power factor in the process of use, which leads to the inaccuracy of only meters in the field environment, and there is an unknown measurement risk. In order to achieve the accurate on-site verification of smart energy meters in normal working conditions, this paper studies the accuracy of smart energy meter field calibration standard device under different current and power factors, develops the error correction method under non-standard conditions. The correction method adopts the method of establishing reference standard value arrays under non-standard conditions to achieve fast and accurate on-site verification and effective measurement performance evaluation of the smart energy meters in use, to explore the measurement work for on-site calibration of smart energy meters under current and power factor in the actual environment.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 50 条
  • [21] A non-standard auxiliary integrating sphere and correction method for the realization of diffuse reflectance
    Feng, Guojin
    Wang, Yu
    Ma, Yu
    Li, Ping
    Zheng, Chundi
    OPTIK, 2013, 124 (20): : 4325 - 4327
  • [22] Author Correction: Selective advantage of trisomic human cells cultured in non-standard conditions
    Samuel D. Rutledge
    Temple A. Douglas
    Joshua M. Nicholson
    Maria Vila-Casadesús
    Courtney L. Kantzler
    Darawalee Wangsa
    Monika Barroso-Vilares
    Shiv D. Kale
    Elsa Logarinho
    Daniela Cimini
    Scientific Reports, 12
  • [23] Choice of a suitable calibration method for automatic vector network analyzers with non-standard connectors
    Kostevc, Drago
    ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2007, 74 (1-2): : 37 - 42
  • [24] Choice of a suitable calibration method for automatic vector network analyzers with non-standard connectors
    Kostevc, Drago
    Elektrotehniski Vestnik/Electrotechnical Review, 2007, 74 (1-2): : 37 - 42
  • [25] Operation of Adjustable-Speed Drives under Non-Standard Supply Conditions
    Chomat, Miroslav
    Schreier, Ludek
    Bendl, Jiri
    CONFERENCE RECORD OF THE 2007 IEEE INDUSTRY APPLICATIONS CONFERENCE FORTY-SECOND IAS ANNUAL MEETING, VOLS. 1-5, 2007, : 262 - 267
  • [26] Second order asymptotics for M-estimators under non-standard conditions
    Hengartner, NW
    Wegkamp, MH
    First Erich L. Lehmann Symposium - Optimality, 2004, 44 : 107 - 124
  • [27] Likelihood ratio testing for hidden markov models under non-standard conditions
    Dannemann, Joern
    Holzmann, Hajo
    SCANDINAVIAN JOURNAL OF STATISTICS, 2008, 35 (02) : 309 - 321
  • [28] NON-STANDARD HIC AND SSC TESTING UNDER MORE SEVERE TEST CONDITIONS
    Schmidt, Tanja
    Haase, Thomas
    Bosch, Christoph
    PROCEEDINGS OF THE 9TH INTERNATIONAL PIPELINE CONFERENCE - 2012, VOL 3, 2013, : 167 - 173
  • [29] 3D coordinate computation by RSA under non-standard conditions
    Soavi, R
    Motta, M
    Visani, A
    Bragonzoni, L
    Loreti, I
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 570 - 572
  • [30] A method for modelling photovoltaic modules under non-standard conditions of solar radiation and ambient temperature in Quibdó, Colombia
    Aristizábal, Andrés Julián (andresj.aristizabalc@utadeo.edu.co), 1600, Taylor and Francis Ltd. (39):