Management of pediatric radiation dose using GE's Revolution digital radiography systems

被引:2
|
作者
Jabri, KN [1 ]
Uppaluri, R [1 ]
Xue, P [1 ]
机构
[1] GE Healthcare, Waukesha, WI 53188 USA
关键词
digital radiography; pediatric radiography; pediatric dose; low-dose processing; image quality;
D O I
10.1007/s00247-004-1272-y
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Digital flat-panel x-ray detectors offer excellent image quality and dose efficiency in addition to clinical productivity, connectivity, and adaptability to advanced clinical applications. GE's Revolution systems provide two modes of exposure control for setting the dose operating point, fixed time and automatic exposure control, the latter of which maintains high image signal-to-noise ratio for the given technique settings. In addition to enhancing detail contrast and compressing the dynamic range, postprocessing automatically determines the best window level and width for display, taking into account the dose at which the image was acquired. Several studies have examined the reduction in patient dose achievable with Revolution systems as compared to competing technologies, and results indicate significant dose savings with equivalent or superior image quality. For pediatric exams, pediatric default techniques provide for a lower patient dose as compared to adult techniques. Therefore, GE's Revolution systems can achieve a high image quality-to-dose ratio for pediatric imaging using the combined advantages of dose-efficient detection, advanced postprocessing, and independently adjustable pediatric techniques.
引用
收藏
页码:S215 / S220
页数:6
相关论文
共 50 条
  • [21] Radiation dose reduction in direct digital panoramic radiography
    Gavala, Sophia
    Donta, Catherine
    Tsiklakis, Kostas
    Boziari, Argyro
    Kamenopoulou, Vasiliki
    Stamatakis, Harry C.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (01) : 42 - 48
  • [22] DOSE EFFICIENCY OF SCREEN FILM SYSTEMS IN PEDIATRIC RADIOGRAPHY
    COHEN, G
    WAGNER, LK
    MCDANIEL, DL
    MEDICAL PHYSICS, 1983, 10 (04) : 541 - 542
  • [23] Digital radiography of scoliosis with a scanning method: radiation dose optimization
    Håkan Geijer
    Bert Verdonck
    Karl-Wilhelm Beckman
    Torbjörn Andersson
    Jan Persliden
    European Radiology, 2003, 13 : 543 - 551
  • [24] ASSESSMENT OF RADIATION-DOSE IN DIGITAL STORAGE PHOSPHOR RADIOGRAPHY
    BICK, U
    FIEBICH, M
    LENZEN, H
    WIESMANN, W
    PETERS, PE
    RADIOLOGE, 1991, 31 (01): : 8 - 10
  • [25] Digital radiography of scoliosis with a scanning method: radiation dose optimization
    Geijer, H
    Verdonck, B
    Beckman, KW
    Andersson, T
    Persliden, J
    EUROPEAN RADIOLOGY, 2003, 13 (03) : 543 - 551
  • [26] Assessment Of Radiation Dose In Digital Radiography System -A Review Article
    Pise, Kunal
    Tivaskar, Suhas
    Luharia, Anurag
    Dhande, Rajasbala
    Pathade, Aniket
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 69 - 75
  • [27] Digital radiography in paediatrics: radiation dose considerations and magnitude of possible dose reduction
    Hufton, AP
    Doyle, SM
    Carty, HML
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (842): : 186 - 199
  • [28] Radiation Dose Management in Pediatric CT
    Verdun F.R.
    Alamo L.
    Miéville F.A.
    Gudinchet F.
    Current Radiology Reports, 2013, 1 (1) : 23 - 29
  • [29] New image quality and dose reduction technique for pediatric digital radiography
    Feghali, Joelle A.
    Chambers, Greg
    Delepierre, Julie
    Chapeliere, Sophie
    Mannes, Ines
    Adamsbaum, Catherine
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (7-8) : 463 - 470
  • [30] Radiation Dose Reduction in Digital Radiography Using Wavelet-Based Image Processing Methods
    Watanabe, Haruyuki
    Tsai, Du-Yih
    Lee, Yongbum
    Matsuyama, Eri
    Kojima, Katsuyuki
    MEDICAL IMAGING 2011: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2011, 7966