Management of pediatric radiation dose using GE's Revolution digital radiography systems

被引:2
|
作者
Jabri, KN [1 ]
Uppaluri, R [1 ]
Xue, P [1 ]
机构
[1] GE Healthcare, Waukesha, WI 53188 USA
关键词
digital radiography; pediatric radiography; pediatric dose; low-dose processing; image quality;
D O I
10.1007/s00247-004-1272-y
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Digital flat-panel x-ray detectors offer excellent image quality and dose efficiency in addition to clinical productivity, connectivity, and adaptability to advanced clinical applications. GE's Revolution systems provide two modes of exposure control for setting the dose operating point, fixed time and automatic exposure control, the latter of which maintains high image signal-to-noise ratio for the given technique settings. In addition to enhancing detail contrast and compressing the dynamic range, postprocessing automatically determines the best window level and width for display, taking into account the dose at which the image was acquired. Several studies have examined the reduction in patient dose achievable with Revolution systems as compared to competing technologies, and results indicate significant dose savings with equivalent or superior image quality. For pediatric exams, pediatric default techniques provide for a lower patient dose as compared to adult techniques. Therefore, GE's Revolution systems can achieve a high image quality-to-dose ratio for pediatric imaging using the combined advantages of dose-efficient detection, advanced postprocessing, and independently adjustable pediatric techniques.
引用
收藏
页码:S215 / S220
页数:6
相关论文
共 50 条
  • [1] Management of pediatric radiation dose using GE’s Revolution digital radiography systems
    K.N. Jabri
    R. Uppaluri
    P. Xue
    Pediatric Radiology, 2004, 34 : S215 - S220
  • [2] Management of pediatric radiation dose using Canon digital radiography
    M. Arreola
    L. Rill
    Pediatric Radiology, 2004, 34 : S221 - S226
  • [3] Management of pediatric radiation dose using Philips digital radiography
    U. Neitzel
    Pediatric Radiology, 2004, 34 : S227 - S233
  • [4] Management of pediatric radiation dose using Philips digital radiography
    Neitzel, U
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S227 - S233
  • [5] Management of pediatric radiation dose using Canon digital radiography
    Arreola, M
    Rill, L
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S221 - S226
  • [6] Management of pediatric radiation dose using Philips digital radiography - Discussion
    Burns, C
    Willis
    Seibert
    MacCutcheon
    Junewick, J
    Schaetzing
    Gorman, A
    Arreola
    Buczkowski, D
    Neitzel
    Jabri
    Aelvoet, R
    Huda
    Podimannil, P
    Westra, S
    Shope, T
    Slovis, T
    Kleinman, P
    Don
    PEDIATRIC RADIOLOGY, 2004, 34 : S234 - S241
  • [7] Management of pediatric radiation dose using Fuji computed radiography
    D.W. MacCutcheon
    Pediatric Radiology, 2004, 34 : S201 - S206
  • [8] Improving pediatric radiation dose management using Agfa digital radiography DICOM header information
    Juste, B.
    Villaescusa, N.
    Granero, D.
    Verdu, G.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4457 - +
  • [9] Management of pediatric radiation dose using Fuji computed radiography
    MacCutcheon, DW
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S201 - S206
  • [10] Management of pediatric radiation dose using Agfa computed radiography
    R. Schaetzing
    Pediatric Radiology, 2004, 34 : S207 - S214