How does urban wastewater treatment affect the microbial quality of treated wastewater?

被引:24
|
作者
Lopez, Andrea [1 ]
Rodriguez-Chueca, Jorge [2 ]
Mosteo, Rosa [1 ]
Gomez, Jairo [3 ]
Rubio, E. [4 ]
Goni, Pilar [4 ]
Ormad, Maria P. [1 ]
机构
[1] Univ Zaragoza, Water Qual & Treatment Res Grp, Dept Chem Engn & Environm Technol, Inst Environm Sci Aragon, Maria dee Luna 3, Zaragoza 50018, Spain
[2] Univ Politecn Madrid, Dept Ind Chem & Environm Engn, Escuela Tecn Super Ingenieros Ind, Calle Jose Gutierrez Abascal 2, E-28006 Madrid, Spain
[3] NILSA, Avda Baranain 22, Pamplona 31008, Spain
[4] Univ Zaragoza, Dept Microbiol Prevent Med & Publ Hlth, Fac Med, C Domingo Miral S-N, E-50009 Zaragoza, Spain
关键词
Urban wastewater treatment; Microbiological quality; Natural receiving waters; Tertiary treatment; Bacteria elimination; Unitary processes; ANTIBIOTIC-RESISTANCE GENES; ESCHERICHIA-COLI; STAPHYLOCOCCUS-AUREUS; COMMUNITY STRUCTURE; TREATMENT PLANTS; BACTERIA; REMOVAL; RIVER; IDENTIFICATION; CONTAMINATION;
D O I
10.1016/j.psep.2019.07.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The design of wastewater treatment plants (WWTP) includes facilities for the removal of suspended solids, organic matter, nitrogen and phosphorous, as required in current legislation, while removal of microorganisms is not literally emphasized. Although the different unit processes have some effect on microbial populations, disinfection is not achieved in many cases unless a specific step is included to regenerate wastewater. This study assesses the effect of the unit processes of six WWTPs that treat municipal wastewater on five microbiological parameters (total coliforms, E. coli, Enterococcus sp., Staphylococcus aureus and Pseudomonas aeruginosa), as well as their contribution to receiving waters. Bacterial concentration in the inlet of WWTPs varies from the lowest concentration of Staphylococcus aureus (10(4) CFU/100 mL), to the highest for total coliforms (10(8) CFU/100 mL), independently of the industrial activity discharging to the WWTP. Considering log bacterial removal of each step of treatment processes, trickling filters reduced 2.6 and 1.5-log Enterococcus sp. and Pseudomonas sp. respectively, secondary decanters achieved 2.5-log average removals and ponds reduced bacteria in a range from 1 to 2.2-log, being the processes with the highest bacteria removal, although in the case of secondary decanters this depends on design parameters such as hydraulic residence time, loads of solids, or types of previous biological treatments. The average of the bacteria concentration in the outlet of the six WWTPs was between 10(3)-10(6) CFU/100 mL. The effect of discharging these bacteria on the quality of receiving waters was assessed by analyzing microbial concentration upstream and downstream of the discharge point. In almost all cases, the bacterial concentration upstream of the discharge point was similar to downstream concentration because the effluent is rapidly diluted in the receiving river, not representing a risk to ecosystems. (C) 2019 Published by Elsevier B.V. on behalf of Institution of Chemical Engineers.
引用
收藏
页码:22 / 30
页数:9
相关论文
共 50 条
  • [41] Primary settling changes the microbial community of influent wastewater to wastewater treatment plants
    Riisgaard-Jensen, Marie
    Dottorini, Giulia
    Nierychlo, Marta
    Nielsen, Per Halkjaer
    WATER RESEARCH, 2023, 244
  • [42] Microbial Counts and Antibiotic Resistances during Conventional Wastewater Treatment and Wastewater Ozonation
    Kirchner, K.
    Brueckner, I
    Klaer, K.
    Hammers-Wirtz, M.
    Pinnekamp, J.
    Rosenbaum, M. A.
    OZONE-SCIENCE & ENGINEERING, 2020, 42 (02) : 108 - 119
  • [43] Investigation of organic micropollutants in urban wastewater and the feasibility of reusing treated wastewater for irrigation purposes
    Simarro-Gimeno, Claudia
    Otoukesh, Mahdiyeh
    Galvis, Efraim A. Serna
    Torres-Palma, Ricardo A.
    Pitarch, Elena
    Hernandez, Felix
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2025, 13 (03):
  • [44] How Does the Ecological and Environmental Damage Compensation System Affect Industrial Wastewater Discharge in China?
    Huang, Shih-Ting
    Zhang, Yuqi
    Yi, Tianjiao
    Zhang, Li
    SUSTAINABILITY, 2025, 17 (05)
  • [45] Mathematical Modeling of Microbial Electrolysis Cells for Enhanced Urban Wastewater Treatment and Hydrogen Generation
    Rahimi, Narges
    Eicker, Ursula
    PROCESSES, 2023, 11 (04)
  • [46] Assessing the effects of salinity on microbial communities and pollutant removal in urban wastewater treatment plants
    Salcedo, Alvaro Javier Moyano
    Canedo-Arguelles, Miguel
    Kaushal, Sujay S.
    Ciriero-Cebrian, Eva Maria
    Perez-Blanco, Adria
    Salvado, Humbert
    JOURNAL OF WATER PROCESS ENGINEERING, 2024, 66
  • [47] Sustainable treatment of urban wastewater using a constructed wetland coupled with a microbial fuel cell
    Modini, Laura
    Pizarro, Ana
    Zerbatto, Mariel
    INGENIERIA DEL AGUA, 2023, 27 (04): : 283 - 293
  • [48] Ozone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessment
    Presumido, Pedro H.
    Ribeirinho-Soares, Sara
    Montes, Rosa
    Quintana, Jose Benito
    Rodil, Rosario
    Ribeiro, Marta
    Neuparth, Teresa
    Santos, Miguel M.
    Feliciano, Manuel
    Nunes, Olga C.
    Gomes, Ana I.
    Vilar, Vitor J. P.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 892
  • [49] The role of microbial electrolysis cell in urban wastewater treatment: integration options, challenges, and prospects
    Katuri, Krishna P.
    Ali, Muhammad
    Saikaly, Pascal E.
    CURRENT OPINION IN BIOTECHNOLOGY, 2019, 57 : 101 - 110
  • [50] Antibiotic Resistance in Czech Urban Wastewater Treatment Plants: Microbial and Molecular Genetic Characterization
    Svobodova, Katerina
    Semerad, Jaroslav
    Petrackova, Denisa
    Novotny, Cenek
    MICROBIAL DRUG RESISTANCE, 2018, 24 (06) : 830 - 838