Is high-dose fluticasone propionate via a metered-dose inhaler and Volumatic™ as efficacious as nebulized budesonide in adult asthmatics?

被引:17
|
作者
O'Reilly, JF
Weir, DC
Banham, S
Basran, GS
Boyd, G
Patel, KR
机构
[1] Blackpool Victoria Hosp, NHS Trust, Dept Resp Med, Blackpool FY3 8NR, Lancs, England
[2] N Manchester Gen Hosp, Manchester, Lancs, England
[3] Glasgow Royal Infirm, Glasgow G4 0SF, Lanark, Scotland
[4] Rotherham Dist Gen Hosp, Rotherham, S Yorkshire, England
[5] Stobhill Gen Hosp, Glasgow G21 3UW, Lanark, Scotland
[6] Univ Glasgow, Western Infirm, Glasgow G11 6NT, Lanark, Scotland
关键词
D O I
10.1016/S0954-6111(98)90041-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The efficacy and tolerability of fluticasone propionate (FP) 2 mg daily via a metered-dose inhaler and Volumatic(TM) (Glaxo Wellcome) spacer device was compared with nebulized budesonide (nBUD), 2 and 4 mg daily, in a multi-centre, open-label, cross-over study of adult asthmatics. Patients received, in random order, either 4 weeks of treatment with FP followed by 4 weeks of treatment with nBUD, or vice versa, with an intervening 4 week 'wash-out' period between treatments. Thirty patients completed the study, of whom 24 were evaluable. In terms of the primary efficacy parameter, change in mean morning peak expiratory flow (PEF) (l min(-1)) from baseline to the fourth week of each treatment period, FP was more effective than nBUD [mean difference (FP-nBUD) 21.1 l min(-1), P=0.007, 95% CI (6.5, 35.7)]. Sub-group analysis demonstrated FP to be superior to the 4 mg nBUD [mean treatment difference (FP-nBUD) 42.91 l min(-1), P=0.026, 95% CI (7.1, 78.8)] and at least as efficacious as the 2 mg nBUD sub-group [mean treatment difference (FP-nBUD) 10.2 l min(-1), P=0.211, 95% CI (-6.5, 26.9)]. Furthermore, larger reductions in diurnal variation were observed during FP treatment [mean treatment difference (FP-nBUD) -4.4 percentage points, P=0.028, 95% CI (-8.4, -0.5)]. There was no significant difference between the treatments for-the proportion of symptom-free 24 h periods. Of those expressing a preference, significantly more patients found FP via a metered-dose inhaler and spacer device both easier to administer (78%, P=0.007) and more convenient to take (76%; P=0.008) than nebulized budesonide. In addition, cost per patient analysis showed that nebulized budesonide was from 1.7 to 3.5 times more expensive than FP.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 50 条
  • [31] Efficacy and safety of salmeterol/fluticasone propionate combination delivered by the Diskus™or pressurised metered-dose inhaler in children with asthma
    Bracamonte, T
    Schauer, U
    Emeryk, A
    Godwood, A
    Balsara, S
    CLINICAL DRUG INVESTIGATION, 2005, 25 (01) : 1 - 11
  • [32] A new fixed dose combination of fluticasone and formoterol in a pressurised metered-dose inhaler for the treatment of asthma
    Devillier, R.
    Salvator, H.
    Grassin-Delyle, S.
    Naline, E.
    Advenier, C.
    Roche, N.
    REVUE DES MALADIES RESPIRATOIRES, 2014, 31 (08) : 700 - 713
  • [33] Early bronchodilatory effects of Budesonide/Formoterol pressurized metered-dose inhaler (pMDI) compared with fluticasone Propionate/Salmeterol dry powder inhaler (DPI) and albuterol pMDI in adults with asthma
    Hampel, F. C., Jr.
    Martin, P.
    Mezzanotte, W. S.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2008, 121 (02) : S220 - S221
  • [34] Systemic and pulmonary effects of fluticasone administered through a metered-dose inhaler in rats
    Sorkness, RL
    Remus, JL
    Rosenthal, LA
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2004, 114 (05) : 1027 - 1032
  • [35] Efficacy and safety of budesonide administered by pressurized metered-dose inhaler in children with asthma
    Meltzer, Eli O.
    Pearlman, David S.
    Eckerwall, Goran
    Uryniak, Tom
    DePietro, Michael
    Lampl, Kathy
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2015, 115 (06) : 516 - 522
  • [36] Delay Between Shaking and Actuation of a Hydrofluoroalkane Fluticasone Pressurized Metered-Dose Inhaler
    Berlinski, Ariel
    von Hollen, Dirk
    Pritchard, John N.
    Hatley, Ross H. M.
    RESPIRATORY CARE, 2018, 63 (03) : 289 - 293
  • [37] FLUTICASONE PROPIONATE/FORMOTEROL PRESSURISED METERED-DOSE INHALER '2-3-4' TRAINING PARADIGM AIDS CORRECT INHALER TECHNIQUE
    Bell, D.
    Mansfield, L.
    Lomax, M.
    Dissanayake, S.
    THORAX, 2015, 70 : A153 - A154
  • [39] Pharmacokinetic and Pharmacodynamic Comparison of Fluticasone Propionate/Formoterol Fumarate Administered via a Pressurized Metered-Dose Inhaler and a Novel Breath-Actuated Inhaler in Healthy Volunteers
    Dissanayake, Sanjeeva
    Mundin, Gill
    Woodward, Jo
    Lomax, Mark
    Dalvi, Prashant
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2023, 36 (02) : 65 - 75
  • [40] The functionality of a budesonide/formoterol pressurized metered-dose inhaler with an integrated actuation counter
    Shah, Shailen
    White, Martha
    Uryniak, Tom
    O'Brien, Christopher D.
    ALLERGY AND ASTHMA PROCEEDINGS, 2010, 31 (01) : 40 - 48