Aortic Valve Stenosis Alters Expression of Regional Aortic Wall Shear Stress: New Insights From a 4-Dimensional Flow Magnetic Resonance Imaging Study of 571 Subjects

被引:115
|
作者
van Ooij, Pim [1 ,2 ]
Markl, Michael [2 ,5 ]
Collins, Jeremy D. [2 ]
Carr, James C. [2 ]
Rigsby, Cynthia [6 ]
Bonow, Robert O. [3 ]
Malaisrie, S. Chris [4 ]
McCarthy, Patrick M. [4 ]
Fedak, Paul W. M. [4 ,7 ]
Barker, Alex J. [2 ]
机构
[1] Acad Med Ctr, Dept Radiol, Amsterdam, Netherlands
[2] Northwestern Univ, Feinberg Sch Med, Dept Radiol, 737 N Michigan Ave,Suite 1600, Chicago, IL 60611 USA
[3] Northwestern Univ, Feinberg Sch Med, Dept Med Cardiol, Chicago, IL USA
[4] Northwestern Univ, Feinberg Sch Med, Div Surg Cardiac Surg, Chicago, IL USA
[5] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
[6] Ann & Robert H Lurie Childrens Hosp Chicago, Dept Med Imaging, Chicago, IL USA
[7] Univ Calgary, Dept Cardiac Sci, Calgary, AB, Canada
来源
关键词
aortic disease; aortic valve; aortic valve stenosis; bicuspid aortic valve; magnetic resonance imaging; MRI; DISEASE; ASSOCIATION; ANGIOGRAPHY; PATTERNS;
D O I
10.1161/JAHA.117.005959
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Wall shear stress (WSS) is a stimulus for vessel wall remodeling. Differences in ascending aorta (AAo) hemodynamics have been reported between bicuspid aortic valve (BAV) and tricuspid aortic valve patients with aortic dilatation, but the confounding impact of aortic valve stenosis (AS) is unknown. Methods and Results-Five hundred seventy-one subjects underwent 4-dimensional flow magnetic resonance imaging in the thoracic aorta (210 right-left BAV cusp fusions, 60 right-noncoronary BAV cusp fusions, 245 tricuspid aortic valve patients with aortic dilatation, and 56 healthy controls). There were 166 of 515 (32%) patients with AS. WSS atlases were created to quantify group-specific WSS patterns in the AAo as a function of AS severity. In BAV patients without AS, the different cusp fusion phenotypes resulted in distinct differences in eccentric WSS elevation: right-left BAV patients exhibited increased WSS by 9% to 34% (P<0.001) at the aortic root and along the entire outer curvature of the AAo whereas right-noncoronary BAV patients showed 30% WSS increase (P<0.001) at the distal portion of the AAo. WSS in tricuspid aortic valve patients with aortic dilatation patients with no AS was significantly reduced by 21% to 33% (P<0.01) in 4 of 6 AAo regions. In all patient groups, mild, moderate, and severe AS resulted in a marked increase in regional WSS (P<0.001). Moderate-to-severe AS further increased WSS magnitude and variability in the AAo. Differences between valve phenotypes were no longer apparent. Conclusions-AS significantly alters aortic hemodynamics and WSS independent of aortic valve phenotype and over-rides previously described flow patterns associated with BAV and tricuspid aortic valve with aortic dilatation. Severity of AS must be considered when investigating valve-mediated aortopathy.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Does the AVNeo valve reduce wall stress on the aortic wall? A cardiac magnetic resonance analysis with 4D-flow for the evaluation of aortic valve replacement with the Ozaki technique (vol 64, ezad299, 2023)
    Pirola, Sergio
    Pirola, Selene
    Mastroiacovo, Giorgio
    Bonomi, Alice
    Manchester, Emily L.
    Fisichella, Serena M.
    Maragna, Riccardo
    Baggiano, Andrea
    Mushtaq, Saima
    Muscogiuri, Giuseppe
    Guglielmo, Marco
    Xu, Xiao Yun
    Pontone, Gianluca
    Polvani, Gianluca
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2024, 65 (04)
  • [42] Letter by Shar et al Regarding Article, "Low and Oscillatory Wall Shear Stress Is Not Related to Aortic Dilation in Patients With Bicuspid Aortic Valve: A Time-Resolved 3-Dimensional Phase-Contrast Magnetic Resonance Imaging Study"
    Shar, Jason A.
    Liu, Janet
    Atkins, Samantha K.
    Sucosky, Philippe
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2020, 40 (04) : E114 - E115
  • [43] Myocardial Fibrosis in Classical Low-Flow, Low-Gradient Aortic Stenosis Insights From a Cardiovascular Magnetic Resonance Study
    Rosa, Vitor E. E.
    Ribeiro, Henrique B.
    Sampaio, Roney O.
    Morais, Thamara C.
    Rosa, Marcela E. E.
    Pires, Lucas J. T.
    Vieira, Marcelo L. C.
    Mathias, Wilson, Jr.
    Rochitte, Carlos E.
    de Santis, Antonio S. A. L.
    Fernandes, Joao Ricardo C.
    Accorsi, Tarso A. D.
    Pomerantzeff, Pablo M. A.
    Rodes-Cabau, Josep
    Pibarot, Philippe
    Tarasoutchi, Flavio
    CIRCULATION-CARDIOVASCULAR IMAGING, 2019, 12 (05)
  • [44] Low and Oscillatory Wall Shear Stress Is Not Related to Aortic Dilation in Patients With Bicuspid Aortic Valve: A Time-Resolved 3-Dimensional Phase-Contrast Magnetic Resonance Imaging Study (vol 40, pg e10, 2020)
    Dux-Santoy
    Ferreira-Gonzalez, Ignacio
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2021, 41 (02) : E142 - E142
  • [45] Fully quantitative mapping of abnormal aortic velocity and wall shear stress direction in patients with bicuspid aortic valves and repaired coarctation using 4D flow cardiovascular magnetic resonance
    Pim van Ooij
    Emile S. Farag
    Carmen P. S. Blanken
    Aart J. Nederveen
    Maarten Groenink
    R. Nils Planken
    S. Matthijs Boekholdt
    Journal of Cardiovascular Magnetic Resonance, 23
  • [46] Fully quantitative mapping of abnormal aortic velocity and wall shear stress direction in patients with bicuspid aortic valves and repaired coarctation using 4D flow cardiovascular magnetic resonance
    van Ooij, Pim
    Farag, Emile S.
    Blanken, Carmen P. S.
    Nederveen, Aart J.
    Groenink, Maarten
    Planken, R. Nils
    Boekholdt, S. Matthijs
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [47] Assessment of abnormal transvalvular flow and wall shear stress direction for pediatric/young adults with bicuspid aortic valve: A cross-sectional four-dimensional flow study
    Fujiwara, Takashi
    Malone, LaDonna J.
    Chatfield, Kathryn C.
    Berthusen, Alex
    Fonseca, Brian
    Browne, Lorna P.
    Barker, Alex J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2024, 26 (02)
  • [48] The use of 4-dimensional flow magnetic resonance imaging and fluid structure interaction analysis to predict failure of medical therapy in acute uncomplicated type B aortic dissection
    Cebull, Hannah L.
    Liu, Minliang
    Piccinelli, Marina
    Dong, Hai
    Naeem, Muhammad
    Du, Yuhang
    Oshinski, John N.
    Gleason, Rudolph L.
    Elefteriades, John A.
    Leshnower, Bradley G.
    JTCVS TECHNIQUES, 2024, 27 : 40 - 44
  • [49] Response by Dux-Santoy et al to Letter Regarding Article, "Low and Oscillatory Wall Shear Stress Is Not Related to Aortic Dilation in Patients With Bicuspid Aortic Valve: A Time-Resolved 3-Dimensional Phase-Contrast Magnetic Resonance Imaging Study"
    Dux-Santoy, Lydia
    Guala, Andrea
    Sotelo, Julio
    Uribe, Sergio
    Teixido-Tura, Gisela
    Evangelista, Arturo
    Rodriguez-Palomares, Jose F.
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2020, 40 (04) : E116 - E117
  • [50] Wall shear stress and relative residence time as potential risk factors for abdominal aortic aneurysms in males: a 4D flow cardiovascular magnetic resonance case–control study
    Chiara Trenti
    Magnus Ziegler
    Niclas Bjarnegård
    Tino Ebbers
    Marcus Lindenberger
    Petter Dyverfeldt
    Journal of Cardiovascular Magnetic Resonance, 24