Characterization of the microbunch time structure of proton pencil beams at a clinical treatment facility

被引:34
|
作者
Petzoldt, J. [1 ,2 ]
Roemer, K. E. [3 ]
Enghardt, W. [1 ,2 ,4 ,5 ,8 ]
Fiedler, F. [3 ]
Golnik, C. [1 ,2 ]
Hueso-Gonzalez, F. [4 ]
Helmbrecht, S. [3 ]
Kormoll, T. [1 ,2 ]
Rohling, H. [3 ]
Smeets, J. [6 ]
Werner, T. [7 ]
Pausch, G. [1 ,2 ]
机构
[1] Fac Med, OncoRay Natl Ctr Radiat Res Oncol, D-01307 Dresden, Germany
[2] Univ Hosp Carl Gustav Carus, D-01307 Dresden, Germany
[3] Helmholtz Zentrum Dresden Rossendorf, Inst Radiat Phys, D-01328 Dresden, Germany
[4] Helmholtz Zentrum Dresden Rossendorf, Inst Radiooncol, D-01328 Dresden, Germany
[5] German Canc Consortium DKTK, Dresden, Germany
[6] Ion Beam Applicat SA, B-1348 Louvain La Neuve, Belgium
[7] Tech Univ Dresden, D-01069 Dresden, Germany
[8] German Canc Res Ctr, Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 06期
关键词
proton therapy; range verification; prompt gamma imaging; prompt gamma-ray timing; beam monitoring; PROMPT-GAMMA DETECTION; RANGE VERIFICATION; CHARGED-PARTICLES; COMPTON CAMERA; SLIT CAMERA; THERAPY; RAYS; FEASIBILITY; IRRADIATION; ENERGY;
D O I
10.1088/0031-9155/61/6/2432
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Proton therapy is an advantageous treatment modality compared to conventional radiotherapy. In contrast to photons, charged particles have a finite range and can thus spare organs at risk. Additionally, the increased ionization density in the so-called Bragg peak close to the particle range can be utilized for maximum dose deposition in the tumour volume. Unfortunately, the accuracy of the therapy can be affected by range uncertainties, which have to be covered by additional safety margins around the treatment volume. A real-time range and dose verification is therefore highly desired and would be key to exploit the major advantages of proton therapy. Prompt gamma rays, produced in nuclear reactions between projectile and target nuclei, can be used to measure the proton's range. The prompt gamma-ray timing (PGT) method aims at obtaining this information by determining the gamma-ray emission time along the proton path using a conventional time-of-flight detector setup. First tests at a clinical accelerator have shown the feasibility to observe range shifts of about 5 mm at clinically relevant doses. However, PGT spectra are smeared out by the bunch time spread. Additionally, accelerator related proton bunch drifts against the radio frequency have been detected, preventing a potential range verification. At OncoRay, first experiments using a proton bunch monitor (PBM) at a clinical pencil beam have been conducted. Elastic proton scattering at a hydrogen-containing foil could be utilized to create a coincident proton-proton signal in two identical PBMs. The selection of coincident events helped to suppress uncorrelated background. The PBM setup was used as time reference for a PGT detector to correct for potential bunch drifts. Furthermore, the corrected PGT data were used to image an inhomogeneous phantom. In a further systematic measurement campaign, the bunch time spread and the proton transmission rate were measured for several beam energies between 69 and 225 MeV as well as for variable momentum limiting slit openings. We conclude that the usage of a PBM increases the robustness of the PGT method in clinical conditions and that the obtained data will help to create reliable range verification procedures in clinical routine.
引用
收藏
页码:2432 / 2456
页数:25
相关论文
共 50 条
  • [31] Time and Manpower Requirements for Clinical Commissioning of the Passively Scattered Proton Beams at PTC-H
    Gillin, M.
    Zhu, X.
    Sahoo, N.
    Lii, M.
    Arjomandy, B.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [32] Dosimetric Investigation of Inverse-Optimized Proton GRID and Lattice Treatment Plans with a Clinical Pencil Beam Scanning System
    Zhu, M.
    Chen, H.
    Snyder, J.
    Regine, W.
    Bradley, J.
    McDonald, M.
    Patel, P.
    Sabouri, P.
    Langen, K.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [33] Combining rescanning and gating for a time-efficient treatment of mobile tumors using pencil beam scanning proton therapy
    Gut, Pauline
    Krieger, Miriam
    Lomax, Tony
    Weber, Damien C.
    Hrbacek, Jan
    RADIOTHERAPY AND ONCOLOGY, 2021, 160 : 82 - 89
  • [34] Single Institution Experience with Clinical Implementation of Uniform Scanning Proton Beams for Ocular Melanoma Treatment
    Grewal, H.
    Chacko, M.
    Rana, S.
    Jin, H.
    Storey, M.
    Chang, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E849 - E849
  • [35] Monte Carlo simulation and polymer gel dosimetry of 60 MeV clinical proton beams for the treatment of ocular tumours
    Baker, C. R.
    Quine, T. E.
    Brunt, J. N. H.
    Kacperek, A.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (03) : 402 - 405
  • [36] Clinical commissioning of an in vivo range verification system for prostate cancer treatment with anterior and anterior oblique proton beams
    Hoesl, M.
    Deepak, S.
    Moteabbed, M.
    Jassens, G.
    Orban, J.
    Park, Y. K.
    Parodi, K.
    Bentefour, E. H.
    Lu, H. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (08): : 3049 - 3062
  • [37] Characterization of a GEM-based scintillation detector with He-CF4 gas mixture in clinical proton beams
    Nichiporov, D.
    Coutinho, L.
    Klyachko, A. V.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (08): : 2972 - 2990
  • [38] Characterization and quenching correction for a 2D real time radioluminescent system in therapeutic proton and carbon charged beams
    Nascimento, L. F.
    Leblans, P.
    van der Heyden, B.
    Akselrod, M.
    Goossens, J.
    Verellen, D.
    Kodaira, S.
    SENSORS AND ACTUATORS A-PHYSICAL, 2022, 345
  • [39] A comprehensive pre-clinical treatment quality assurance program using unique spot patterns for proton pencil beam scanning FLASH radiotherapy
    Tsai, Pingfang
    Yang, Yunjie
    Wu, Mengjou
    Chen, Chin-Cheng
    Yu, Francis
    Simone II, Charles B.
    Choi, Jehee Isabelle
    Tome, Wolfgang A.
    Lin, Haibo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):
  • [40] Clinical validation of a GPU-based Monte Carlo dose engine of a commercial treatment planning system for pencil beam scanning proton therapy
    Fracchiolla, Francesco
    Engwall, Erik
    Janson, Martin
    Tamm, Fredrik
    Lorentini, Stefano
    Fellin, Francesco
    Bertolini, Mattia
    Algranati, Carlo
    Righetto, Roberto
    Farace, Paolo
    Amichetti, Maurizio
    Schwarz, Marco
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 226 - 234