Characterization of the microbunch time structure of proton pencil beams at a clinical treatment facility

被引:34
|
作者
Petzoldt, J. [1 ,2 ]
Roemer, K. E. [3 ]
Enghardt, W. [1 ,2 ,4 ,5 ,8 ]
Fiedler, F. [3 ]
Golnik, C. [1 ,2 ]
Hueso-Gonzalez, F. [4 ]
Helmbrecht, S. [3 ]
Kormoll, T. [1 ,2 ]
Rohling, H. [3 ]
Smeets, J. [6 ]
Werner, T. [7 ]
Pausch, G. [1 ,2 ]
机构
[1] Fac Med, OncoRay Natl Ctr Radiat Res Oncol, D-01307 Dresden, Germany
[2] Univ Hosp Carl Gustav Carus, D-01307 Dresden, Germany
[3] Helmholtz Zentrum Dresden Rossendorf, Inst Radiat Phys, D-01328 Dresden, Germany
[4] Helmholtz Zentrum Dresden Rossendorf, Inst Radiooncol, D-01328 Dresden, Germany
[5] German Canc Consortium DKTK, Dresden, Germany
[6] Ion Beam Applicat SA, B-1348 Louvain La Neuve, Belgium
[7] Tech Univ Dresden, D-01069 Dresden, Germany
[8] German Canc Res Ctr, Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 06期
关键词
proton therapy; range verification; prompt gamma imaging; prompt gamma-ray timing; beam monitoring; PROMPT-GAMMA DETECTION; RANGE VERIFICATION; CHARGED-PARTICLES; COMPTON CAMERA; SLIT CAMERA; THERAPY; RAYS; FEASIBILITY; IRRADIATION; ENERGY;
D O I
10.1088/0031-9155/61/6/2432
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Proton therapy is an advantageous treatment modality compared to conventional radiotherapy. In contrast to photons, charged particles have a finite range and can thus spare organs at risk. Additionally, the increased ionization density in the so-called Bragg peak close to the particle range can be utilized for maximum dose deposition in the tumour volume. Unfortunately, the accuracy of the therapy can be affected by range uncertainties, which have to be covered by additional safety margins around the treatment volume. A real-time range and dose verification is therefore highly desired and would be key to exploit the major advantages of proton therapy. Prompt gamma rays, produced in nuclear reactions between projectile and target nuclei, can be used to measure the proton's range. The prompt gamma-ray timing (PGT) method aims at obtaining this information by determining the gamma-ray emission time along the proton path using a conventional time-of-flight detector setup. First tests at a clinical accelerator have shown the feasibility to observe range shifts of about 5 mm at clinically relevant doses. However, PGT spectra are smeared out by the bunch time spread. Additionally, accelerator related proton bunch drifts against the radio frequency have been detected, preventing a potential range verification. At OncoRay, first experiments using a proton bunch monitor (PBM) at a clinical pencil beam have been conducted. Elastic proton scattering at a hydrogen-containing foil could be utilized to create a coincident proton-proton signal in two identical PBMs. The selection of coincident events helped to suppress uncorrelated background. The PBM setup was used as time reference for a PGT detector to correct for potential bunch drifts. Furthermore, the corrected PGT data were used to image an inhomogeneous phantom. In a further systematic measurement campaign, the bunch time spread and the proton transmission rate were measured for several beam energies between 69 and 225 MeV as well as for variable momentum limiting slit openings. We conclude that the usage of a PBM increases the robustness of the PGT method in clinical conditions and that the obtained data will help to create reliable range verification procedures in clinical routine.
引用
收藏
页码:2432 / 2456
页数:25
相关论文
共 50 条
  • [1] Emulsion detectors for dose distribution characterization in the halo of proton pencil beams
    Braccini, S.
    Ariga, A.
    Ariga, T.
    Ereditato, A.
    Giacoppo, F.
    Nesteruk, K. P.
    Pistillo, C.
    Scampoli, P.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (01) : 87 - 87
  • [2] Prompt gamma imaging of proton pencil beams at clinical dose rate
    Perali, I.
    Celani, A.
    Bombelli, L.
    Fiorini, C.
    Camera, F.
    Clementel, E.
    Henrotin, S.
    Janssens, G.
    Prieels, D.
    Roellinghoff, F.
    Smeets, J.
    Stichelbaut, F.
    Stappen, F. Vander
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (19): : 5849 - 5871
  • [3] Time structure of pencil beam scanning proton FLASH beams measured with scintillator detectors and compared with log files
    Kanouta, Eleni
    Johansen, Jacob Graversen
    Kertzscher, Gustavo
    Sitarz, Mateusz Krzysztof
    Sorensen, Brita Singers
    Poulsen, Per Rugaard
    MEDICAL PHYSICS, 2022, 49 (03) : 1932 - 1943
  • [4] Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beams
    Pedroni, E
    Scheib, S
    Böhringer, T
    Coray, A
    Grossmann, M
    Lin, S
    Lomax, A
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (03): : 541 - 561
  • [5] Implementation of pencil kernel and depth penetration algorithms for treatment planning of proton beams
    Russell, KR
    Isacsson, U
    Saxner, M
    Ahnesjö, A
    Montelius, A
    Grusell, E
    Dahlgren, CV
    Lorin, S
    Glimelius, B
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (01): : 9 - 27
  • [6] Validation and Clinical Implementation of a Full Monte Carlo Code for Scanned Proton Pencil Beams
    Huang, S.
    Kang, M.
    Souris, K.
    Ainsley, C.
    Solberg, T.
    McDonough, J.
    Simone, C.
    Lin, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3180 - 3181
  • [7] Monte Carlo and analytical calculation of proton pencil beams for computerized treatment plan optimization
    Carlsson, AK
    Andreo, P
    Brahme, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (06): : 1033 - 1053
  • [8] Comparative Clinical Pencil Beam Scanned Proton Flash Therapy: Transmission Beams Vs. Range Stopping Beams
    Farr, J.
    Kolano, A.
    Gray, T.
    Liu, C.
    Xia, P.
    MEDICAL PHYSICS, 2022, 49 (06) : E865 - E865
  • [9] Dosimetric data for broad beam, pencil beam and Monte Carlo models of clinical proton beams
    Mazal, A
    Kooy, H
    Nauraye, C
    Schaffner, B
    Rosenthal, S
    Kollipara, S
    Paganetti, H
    Ferrand, R
    Rosenwald, JC
    Chen, G
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S321 - S321
  • [10] Experimental characterization of lateral profiles of scanned proton and carbon ion pencil beams for improved beam models in ion therapy treatment planning
    Schwaab, J.
    Brons, S.
    Fieres, J.
    Parodi, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (24): : 7813 - 7827