A randomized comparison of pediatric-sized Streamlined Liner of Pharyngeal Airway and Laryngeal Mask Airway-Unique in paralyzed children

被引:5
|
作者
Zhu, Wenxiu [1 ]
Wei, Xinchuan [1 ]
机构
[1] Sichuan Univ, Dept Anesthesiol, West China Hosp, 37 Guoxuexiang, Chengdu 610064, Peoples R China
关键词
laryngeal masks; pediatrics; anesthesiology; oropharyngeal leak pressure; airway management; complications; COBRA PERILARYNGEAL AIRWAY; PRESSURE; VENTILATION; ANESTHESIA; SLIPA(TM); INSERTION; LMA; IMPROVES; TRIAL;
D O I
10.1111/pan.12883
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BackgroundThe pediatric-sized Streamlined Liner of Pharyngeal Airway (SLIPA) is a new supraglottic airway device for children. AimsThe aim of this study was to compare the clinical performance of the pediatric-sized SLIPA with the Laryngeal Mask Airway-Unique in paralyzed children under positive pressure-controlled ventilation (PCV). MethodsOne hundred children, aged 2 months to 12 years with American Society of Anesthesiologists physical status I-II were enrolled and randomly allocated to the SLIPA group or the Laryngeal Mask Airway-Unique group (50 patients in each group). The primary outcome variable was oropharyngeal leak pressure. Other outcome variables were first insertion success rate, insertion time, minor airway interventions required for successful insertion, intraoperative dislodgement, ventilatory data, and perioperative complications. ResultsThe insertion characteristics, ventilation data, and perioperative complications were comparable between the two groups. The leak pressure of the SLIPA was significantly higher than that of the Laryngeal Mask Airway-Unique [median (IQR): 25 (22-30) cmH(2)O vs 21 (19-26) cmH(2)O, respectively; mean sd: 25.3 +/- 4.6 cmH(2)O vs 22.6 +/- 4.8 cmH(2)O, respectively; P = 0.006]. The incidence of intraoperative dislodgment was significantly lower in the SLIPA group than in the Laryngeal Mask Airway-Unique group (0 vs 6 patients, respectively; P = 0.027). ConclusionsIn conclusion, both the SLIPA and the Laryngeal Mask Airway-Unique can be used effectively without severe complications in paralyzed children. Additionally, the SLIPA provides a better airway seal and better intraoperative position stability than the Laryngeal Mask Airway-Unique.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 50 条
  • [31] Comparison of laryngeal mask airway supreme and laryngeal mask airway proseal for laryngopharyngeal trauma and postoperative morbidity in children
    Aydogmus, Meltem Turkay
    Eksioglu, Birsen
    Oba, Sibel
    Unsal, Oya
    Turk, Hacer Sebnem Yeltepe
    Sinikoglu, Saki Nadir
    Tug, Aslihan
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2013, 63 (06): : 445 - 449
  • [32] The effectiveness and patient comfort of the novel streamlined pharynx airway liner (SLIPA®) compared with the conventional laryngeal mask airway in ophthalmic surgery
    Lange, Markus
    Smul, Thorsten
    Zimmermann, Peter
    Kohlenberger, Rudolf
    Roewer, Norbert
    Kehl, Franz
    ANESTHESIA AND ANALGESIA, 2007, 104 (02): : 431 - 434
  • [33] A randomized crossover comparison of the size 2 1/2 laryngeal mask airway ProSeal™ versus Laryngeal Mask Airway-Classic™ in pediatric patients
    Goldmann, K
    Jakob, C
    ANESTHESIA AND ANALGESIA, 2005, 100 (06): : 1605 - 1610
  • [34] Insertion methods comparison for The Streamlined Liner of the Pharynx Airway in children by novice
    Chen, Y.
    Bai, J.
    Wang, R.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2018, 62 (03) : 319 - 327
  • [35] A RANDOMIZED COMPARISON OF THE I-GEL WITH THE PROSEAL LARYNGEAL MASK AIRWAY IN PEDIATRIC PATIENTS
    Fukuhara, A.
    Okutani, R.
    Oda, Y.
    ANESTHESIA AND ANALGESIA, 2012, 114
  • [36] Preheating of streamlined liner of pharyngeal airway (SLIPA) reduced the related complications: a randomized control study
    Geng, Guiqi
    Chen, Yingjie
    Liu, Hailian
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (03) : 547 - 550
  • [37] Preheating of streamlined liner of pharyngeal airway (SLIPA) reduced the related complications: a randomized control study
    Guiqi Geng
    Yingjie Chen
    Hailian Liu
    Journal of Clinical Monitoring and Computing, 2017, 31 : 547 - 550
  • [38] A comparison of pharyngeal mucosal pressure and airway sealing pressure with the laryngeal mask airway in anesthetized adult patients
    Brimacombe, J
    Keller, C
    ANESTHESIA AND ANALGESIA, 1998, 87 (06): : 1379 - 1382
  • [39] Comparison of the Disposable Streamlined Liner of the Pharynx Airway and the Disposable I-gel in Anaesthetized, Paralyzed Adults: A Randomized Prospective Study
    EL-Radaideh, Khaled
    Alhowary, Ala''a
    Hani, Diab Bani
    ANESTHESIOLOGY RESEARCH AND PRACTICE, 2015, 2015
  • [40] The randomized crossover comparison of airway sealing with the laryngeal mask airway Supreme™ at three different intracuff pressures in children
    Choi, Kwan-Woong
    Lee, Jeong-Rim
    Oh, Jung-Tak
    Kim, Dong Wook
    Kim, Min-Soo
    PEDIATRIC ANESTHESIA, 2014, 24 (10) : 1080 - 1087