Quantitative near-infrared spectroscopy on patients with peripheral vascular disease

被引:6
|
作者
Franceschini, MA [1 ]
Fantini, S [1 ]
Palumbo, R [1 ]
Pasqualini, L [1 ]
Vaudo, G [1 ]
Franceschini, E [1 ]
Gratton, E [1 ]
Palumbo, B [1 ]
Innocente, S [1 ]
Mannarino, E [1 ]
机构
[1] Univ Illinois, Dept Phys, Fluorescence Dynam Lab, Urbana, IL 61801 USA
关键词
peripheral vascular disease; near-infrared spectroscopy; hemoglobin saturation; skeletal muscle;
D O I
10.1117/12.301041
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have used near-infrared spectroscopy to measure the hemoglobin saturation at rest and during exercise on patients affected by peripheral vascular disease (PVD). The instrument used in our study is a frequency-domain tissue oximeter which employs intensity modulated (110 MHz) laser diodes. We examined 9 subjects, 3 of which were controls and 6 were patients affected by stage II PVD. The optical probe was located on the calf muscle of the subjects. The measurement protocol consisted of: (1) baseline (similar to 5 min); (2) stationary bicycle exercise (similar to 5 min); (3) recovery (similar to 15 min). The change in hemoglobin saturation during exercise (Delta Y) and the recovery time after exercise (t(rcc)) were significantly greater in the PVD patients (Delta Y = -21+/-3%, t(rcc) = 5.9+/-3.8 min) than in the control subjects (Delta Y = 2+/-3%, t(rcc) = 0.6+/-0.1 min).
引用
收藏
页码:112 / 115
页数:4
相关论文
共 50 条
  • [21] Near-infrared spectroscopy with a provocative maneuver to detect the presence of severe peripheral arterial disease
    Reiter, Homer-Christian J.
    Andersen, Charles A.
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2024, 10 (06):
  • [22] Near-infrared spectroscopy, scintigraphy and transcutaneous oximetry in the diagnosis of peripheral arterial disease.
    Pasqualini, L
    Vaudo, G
    Fantini, S
    Franceschini, MA
    Paoletti, F
    Innocente, S
    Palumbo, R
    Mannarino, E
    ATHEROSCLEROSIS, 1997, 135 : S17 - S17
  • [23] Invasive Characterization of Atherosclerotic Plaque in Patients with Peripheral Arterial Disease Using Near-Infrared Spectroscopy Intravascular Ultrasound
    Abbas, Amr E.
    Zacharias, Sibin K.
    Goldstein, James A.
    Hanson, Ivan D.
    Safian, Robert D.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (03) : 461 - 470
  • [24] Near-infrared spectroscopy
    Misra, M
    Alp, MS
    Dujovny, M
    Ausman, JI
    JOURNAL OF NEUROSURGERY, 1996, 85 (02) : 363 - 363
  • [25] Near-infrared spectroscopy
    Tsuchikawa, S
    Hayashi, K
    Tsutsumi, S
    APPLIED SPECTROSCOPY, 1996, 50 (09) : 1117 - 1124
  • [26] NEAR-INFRARED SPECTROSCOPY
    HARRIS, DNF
    ANAESTHESIA, 1995, 50 (12) : 1015 - 1016
  • [27] Near-infrared spectroscopy
    Norris, T
    Aldridge, PK
    Sekulic, SS
    ANALYST, 1997, 122 (06) : 549 - 552
  • [28] NEAR-INFRARED SPECTROSCOPY
    EDWARDS, AD
    EUROPEAN JOURNAL OF PEDIATRICS, 1995, 154 (08) : S19 - S21
  • [29] Near-infrared spectroscopy
    Ramsay, SJ
    Gomersall, CD
    ANAESTHESIA, 2002, 57 (06) : 615 - 616
  • [30] NEAR-INFRARED SPECTROSCOPY
    BRAZY, JE
    CLINICS IN PERINATOLOGY, 1991, 18 (03) : 519 - 534