Study of a high-resolution PET system using a Silicon detector probe

被引:15
|
作者
Brzezinski, K. [1 ]
Oliver, J. F. [1 ]
Gillam, J. [1 ]
Rafecas, M. [1 ]
机构
[1] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46980 Valencia, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 20期
关键词
PET; high-resolution imaging; Si detectors; PET insert; ZOOM-IN PET; POSITRON-EMISSION-TOMOGRAPHY; INSERT; SIMULATION; SCANNER; DEVICE; DESIGN; RECONSTRUCTION;
D O I
10.1088/0031-9155/59/20/6117
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A high-resolution silicon detector probe, in coincidence with a conventional PET scanner, is expected to provide images of higher quality than those achievable using the scanner alone. Spatial resolution should improve due to the finer pixelization of the probe detector, while increased sensitivity in the probe vicinity is expected to decrease noise. A PET-probe prototype is being developed utilizing this principle. The system includes a probe consisting of ten layers of silicon detectors, each a 80 x 52 array of 1 x 1 x 1 mm(3) pixels, to be operated in coincidence with a modern clinical PET scanner. Detailed simulation studies of this system have been performed to assess the effect of the additional probe information on the quality of the reconstructed images. A grid of point sources was simulated to study the contribution of the probe to the system resolution at different locations over the field of view (FOV). A resolution phantom was used to demonstrate the effect on image resolution for two probe positions. A homogeneous source distribution with hot and cold regions was used to demonstrate that the localized improvement in resolution does not come at the expense of the overall quality of the image. Since the improvement is constrained to an area close to the probe, breast imaging is proposed as a potential application for the novel geometry. In this sense, a simplified breast phantom, adjacent to heart and torso compartments, was simulated and the effect of the probe on lesion detectability, through measurements of the local contrast recovery coefficient-to-noise ratio (CNR), was observed. The list-mode ML-EM algorithm was used for image reconstruction in all cases. As expected, the point spread function of the PET-probe system was found to be non-isotropic and vary with position, offering improvement in specific regions. Increase in resolution, of factors of up to 2, was observed in the region close to the probe. Images of the resolution phantom showed visible improvement in resolution when including the probe in the simulations. The image quality study demonstrated that contrast and spill-over ratio in other areas of the FOV were not sacrificed for this enhancement. The CNR study performed on the breast phantom indicates increased lesion detectability provided by the probe.
引用
收藏
页码:6117 / 6140
页数:24
相关论文
共 50 条
  • [21] SILICON TECHNOLOGY IN ION DETECTION - A HIGH-RESOLUTION DETECTOR ARRAY
    BIRKINSHAW, K
    LANGSTAFF, DP
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 132 (03): : 193 - 206
  • [22] First results with high-resolution PET detector modules using wavelength-shifting fibers
    Worstell, W
    Johnson, O
    Kudrolli, H
    Zavarzin, V
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 929 - 933
  • [23] First results with high-resolution PET detector modules using wavelength-shifting fibers
    Boston Univ Physics Dep and Cent for, Photonics, Boston, United States
    IEEE Trans Nucl Sci, 6 pt 2 (2993-2999):
  • [24] Development of a High-Resolution Four-Layer DOI Detector Using MPPCs for Brain PET
    Omura, T.
    Moriya, T.
    Yamada, R.
    Yamauchi, H.
    Saito, A.
    Sakai, T.
    Miwa, T.
    Watanabe, M.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3560 - 3563
  • [25] First results with high-resolution PET detector modules using wavelength-shifting fibers
    Worstell, W
    Johnson, O
    Kudrolli, H
    Zavarzin, V
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 2993 - 2999
  • [26] Development and initial characterization of a high-resolution PET detector module with DOI
    Li, Mohan
    Wang, Yuli
    Abbaszadeh, Shiva
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (06):
  • [27] AN EVALUATION OF A TWO-DIMENSIONAL ARRAY DETECTOR FOR HIGH-RESOLUTION PET
    DAHLBOM, M
    HOFFMAN, EJ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) : 264 - 272
  • [28] Online detector response calculations for high-resolution PET image reconstruction
    Pratx, Guillem
    Levin, Craig
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (13): : 4023 - 4040
  • [29] A high-resolution CT system using intraoral x-ray detector
    Chen, SK
    Chen, CM
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 798 - 802
  • [30] Design study of a PET detector with 0.5 mm crystal pitch for high-resolution preclinical imaging
    Zhang, Xi
    Yu, Hongsen
    Xie, Qiangqiang
    Xie, Siwei
    Ye, Baihezi
    Guo, Minghao
    Zhao, Zhixiang
    Huang, Qiu
    Xu, Jianfeng
    Peng, Qiyu
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (13):