Analysis and design of elevated liquid-filled reinforced concrete conical tanks

被引:2
|
作者
Azabi, T. M. [1 ]
El Ansary, A. M. [1 ,2 ]
El Damatty, A. A. [1 ]
机构
[1] Univ Western Ontario, Dept Civil & Environm Engn, London, ON N6A 5B9, Canada
[2] Univ Alexandria, Fac Engn, Alexandria, Egypt
关键词
finite element analysis; hydrostatic loading; reinforced concrete conical tanks; shell structures; SHELL ELEMENT; STABILITY;
D O I
10.1177/1369433216630824
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Reinforced concrete conical tanks are used in municipalities and industrial applications as liquid containing vessels. These tanks can be ground supported tanks or elevated on a supporting shaft. Although most design codes provide guidelines for rectangular and cylindrical tanks, no guidance is provided in these codes for conical tanks. This study focuses on assessing the accuracy of a design approach based on the provisions of Portland Cement Association Circular Concrete Tanks without Pre-stressing code for cylindrical tanks combined with an equivalent cylinder approach provided by the American Water Works Association-D100. Several reinforced concrete conical tanks with different geometric configurations are analyzed under the effect of hydrostatic loading using this approach. The internal forces obtained according to code provisions are compared with those predicted by a linear finite element analysis model developed for all studied tanks. The finite element analysis model is based on a degenerated consistent sub-parametric triangular shell element developed in-house. The results of this comparison show that Portland Cement Association Circular Concrete Tanks without Pre-stressing approach leads to larger hoop tension and smaller meridional moment compared to those obtained from the finite element analysis. Therefore, the Portland Cement Association Circular Concrete Tanks without Pre-stressing provisions combined with the equivalent cylinder approach lead to an inadequate design if applied to conical-shaped tanks.
引用
收藏
页码:995 / 1008
页数:14
相关论文
共 50 条
  • [23] Soil dynamic effects for the design of foundations of liquid-filled tanks under seismic loads
    Schatten, H.
    Holtschoppen, B.
    Michel, P.
    Klinkel, S.
    BAUINGENIEUR, 2017, 92 : 435 - 443
  • [24] Nonlinear buckling optimization technique to predict critical imperfection wavelength of combined liquid-filled steel conical tanks
    MacKay, Rainer J.
    El Ansary, Ayman M.
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (13) : 2799 - 2808
  • [25] Coupled slosh dynamics of liquid-filled, composite cylindrical tanks
    Pal, NC
    Bhattacharyya, SK
    Sinha, PK
    JOURNAL OF ENGINEERING MECHANICS, 1999, 125 (04) : 491 - 495
  • [26] DYNAMIC FLUID EFFECTS IN LIQUID-FILLED FLEXIBLE CYLINDRICAL TANKS
    FISCHER, D
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1979, 7 (06): : 587 - 601
  • [27] Test program and numerical studies on reinforced concrete slabs impacted by liquid-filled missiles
    Heckoetter, Christian
    Vepsa, Ari
    Sievers, Juergen
    NUCLEAR ENGINEERING AND DESIGN, 2025, 435
  • [28] Application of seismic isolation technique to partially filled conical elevated tanks
    Moslemi, Mehdi
    Kianoush, M. Reza
    ENGINEERING STRUCTURES, 2016, 127 : 663 - 675
  • [29] Damage characteristics of liquid-filled tanks impacted by low speed projectiles
    Liu Y.
    Ren P.
    Shi L.
    2018, Chinese Vibration Engineering Society (37): : 84 - 89
  • [30] Study on Equivalent Sloshing Mass Locations for Liquid-Filled Cylindrical Tanks
    Hu, Pengxiang
    Zhao, Zhihua
    Yang, Shutao
    Zeng, Yaoxiang
    Qi, Feng
    JOURNAL OF SPACECRAFT AND ROCKETS, 2022, 59 (02) : 691 - 696