Fabrication And Integration Of PDMS-Glass Based Microfluidic With Optical Absorbance Measurement Device For Coliform Bacteria Detection

被引:0
|
作者
Sahdan, M. Z. [1 ]
Salih, N. M. [1 ]
Morsin, M. [1 ]
Asmah, M. T. [1 ]
Nafarizal, N. [1 ]
Kristiawan, B. [2 ]
Hadi, S. [2 ]
Suyitno, S. [2 ]
Jamaluddin, A. [3 ]
机构
[1] Univ Tun Hussein Onn Malaysia, Microelect & Nanotechnol Shamsuddin Res Ctr MiNT, Batu Pahat 86400, Johor, Malaysia
[2] Univ Sebelas Maret, Mech Engn Dept, Fac Engn, Surakarta 57126, Indonesia
[3] Univ Sebelas Maret, Phys Educ Program, Fac Teacher Training & Educ, Surakarta 57126, Indonesia
关键词
Sensor; Microfluidic; Optoelectronic; Bacteria; CELL;
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The detection of coliform bacteria which contain the disease-causing microorganism is a useful indication for water contamination. Currently, the emerging of technology in molecular biology research and industry is in demand for portable and miniaturized system. This paper demonstrates the development and integration of microfluidic and optical absorbance measurement device for portable coliform bacteria detection. The microfluidic device was fabricated with glass and polydimethylsiloxane (PDMS) material using photolithography, replica molding (soft lithography), and oxygen plasma bonding techniques. Then, the optical absorbance measurement device for coliform bacteria detection was developed using 470 nm blue light emitting diode (LED), photo detector, ARDUINO microcontroller, liquid crystal display (LCD), and mechanical elements. The coliform bacteria suspension sample was inserted into the microfluidic device and the presence of coliform bacteria was analyzed using the developed optical absorbance measurement device. The absorbance measurement from the prototype and colony number of the coliform bacteria samples were collected and analyzed. The final analysis had indicated that the developed prototype was able to detect the coliform bacteria in suspension at the lowest detection of 17,200 CFU/ml.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 31 条
  • [21] Integration of a microfluidic polymerase chain reaction device and surface plasmon resonance fiber sensor into an inline all-in-one platform for pathogenic bacteria detection
    Nguyen, Tan Tai
    Trinh, Kieu The Loan
    Yoon, Won Jung
    Lee, Nae Yoon
    Ju, Heongkyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 242 : 1 - 8
  • [22] Detection of glycated hemoglobin (HbA1c) based on impedance measurement with parallel electrodes integrated into a microfluidic device
    Chuang, Ya-Chun
    Lan, Kung-Chieh
    Hsieh, Ku-Meng
    Jang, Ling-Sheng
    Chen, Ming-Kun
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 1222 - 1230
  • [23] Integrated ZnO Nanoparticles on Paper-based Microfluidic: Toward Efficient Analytical Device for Glucose Detection based on Impedance and FTIR Measurement
    Yuwono, Rio Akbar
    Izdiharruddin, Mokhammad Fahmi
    Wahyuono, Ruri Agung
    SECOND INTERNATIONAL SEMINAR ON PHOTONICS, OPTICS, AND ITS APPLICATIONS (ISPHOA 2016), 2016, 10150
  • [24] RAPID AND ACCURATE BACTERIA DETECTION BASED ON DUAL-WAVELENGTH OPTICAL DENSITY MEASUREMENTS IN MICROFLUIDIC CHIP FOR BACTERIAL INFECTION DIAGNOSIS
    Yang, Ning
    Zhang, Rong-Biao
    Sun, Jun
    Guo, Jian-Jiang
    Sun, Jian
    JOURNAL OF INVESTIGATIVE MEDICINE, 2014, 62 (08) : S77 - S78
  • [25] Development of an online measurement system using an alpha liquid scintillation counter and a glass-based microfluidic solvent extraction device for plutonium analysis
    Yamamoto, Masahiko
    Taguchi, Shigeo
    Do, Van-Khoai
    Kuno, Takehiko
    Surugaya, Naoki
    APPLIED RADIATION AND ISOTOPES, 2019, 152 : 37 - 44
  • [26] 3D-Printed Microfluidic Device for the Detection of Pathogenic Bacteria Using Size-based Separation in Helical Channel with Trapezoid Cross-Section
    Lee, Wonjae
    Kwon, Donghoon
    Choi, Woong
    Jung, Gyoo Yeol
    Jeon, Sangmin
    SCIENTIFIC REPORTS, 2015, 5
  • [27] 3D-Printed Microfluidic Device for the Detection of Pathogenic Bacteria Using Size-based Separation in Helical Channel with Trapezoid Cross-Section
    Wonjae Lee
    Donghoon Kwon
    Woong Choi
    Gyoo Yeol Jung
    Anthony K. Au
    Albert Folch
    Sangmin Jeon
    Scientific Reports, 5
  • [28] Development of a Microfluidic-Based Optical Sensing Device for Label-Free Detection of Circulating Tumor Cells (CTCs) Through Their Lactic Acid Metabolism
    Chiu, Tzu-Keng
    Lei, Kin-Fong
    Hsieh, Chia-Hsun
    Hsiao, Hung-Bo
    Wang, Hung-Ming
    Wu, Min-Hsien
    SENSORS, 2015, 15 (03) : 6789 - 6806
  • [29] Correction: Corrigendum: 3D-Printed Microfluidic Device for the Detection of Pathogenic Bacteria Using Size-based Separation in Helical Channel with Trapezoid Cross-Section
    Wonjae Lee
    Donghoon Kwon
    Woong Choi
    Gyoo Yeol Jung
    Anthony K. Au
    Albert Folch
    Sangmin Jeon
    Scientific Reports, 5
  • [30] 3D-Printed Microfluidic Device for the Detection of Pathogenic Bacteria Using Size-based Separation in Helical Channel with Trapezoid Cross-Section (vol 5, 7717, 2015)
    Lee, Wonjae
    Kwon, Donghoon
    Choi, Woong
    Jung, Gyoo Yeol
    Au, Anthony K.
    Folch, Albert
    Jeon, Sangmin
    SCIENTIFIC REPORTS, 2015, 5