Stepper Motor Wire Breaks Diagnose and Redundant Control System for Factory Automation

被引:0
|
作者
Perera, K. L. A. N. [1 ]
Premachandra, C. [2 ]
Senadeera, P. M. [1 ]
机构
[1] Wayamba Univ, Dept Elect, Kuliyapitiya, Sri Lanka
[2] Shibaura Inst Technol, Dept Elect Engn, Koto Ku, Tokyo, Japan
关键词
Wire breaks diagnose; factory automation; stepper motor; reduction of factory downtime;
D O I
10.1109/ICIP48927.2020.9367363
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
This study introduces a reliable factory automation system to reduce the downtime of factories. This system is based on the feedback voltage monitoring method to identify the fail wires of a stepper motor. This proposed system diagnoses the loose wires and malfunctioning devices in the factory automation system and continues the process with secondary networks and devices. As soon as fail devices or fail wires were recovered, this system automatically continue with the primary device. Then the secondary devices set to sleep mode. This process takes less than one second and the system helps to avoid unplanned production stoppages and breakdowns. Therefore the system reduces factory downtime. Even though there are many breakdown diagnose systems available in the market, novelty of our research is, proposing a loop feedback voltage monitoring system for the industry. Available systems use current flow sensing systems to identify breakdowns. Our proposed system is comparatively faster and lower cost than the available systems. Also, our proposed system can be inbuilt in the stepper motor driver itself.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Feed-forward control of a redundant motor system
    Simon R. Goodman
    Mark L. Latash
    Biological Cybernetics, 2006, 95 : 271 - 280
  • [22] A Control System of Three-axis Stepper Motor Based on the FPGA
    Yu, Juan
    Kang, Hongmei
    Wang, Yuansheng
    Lu, Guiying
    PROCEEDINGS 2013 INTERNATIONAL CONFERENCE ON MECHATRONIC SCIENCES, ELECTRIC ENGINEERING AND COMPUTER (MEC), 2013, : 3334 - 3337
  • [23] Embedded system design for field-oriented stepper motor control
    Rusu, C.
    Szoke, E.
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, VOL IV, 2008, : 63 - 68
  • [24] Feed-forward control of a redundant motor system
    Goodman, Simon R.
    Latash, Mark L.
    BIOLOGICAL CYBERNETICS, 2006, 95 (03) : 271 - 280
  • [25] Modeling of stepper motor control system and optimization of acceleration and deceleration curve
    Wang B.-J.
    Liu Q.-X.
    Zhou L.
    Bu L.
    Li X.-Q.
    Zhang J.-Q.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2018, 22 (01): : 37 - 42and52
  • [26] Stepper motor open-loop control system modeling and control strategy optimization
    Zhang, Daode
    Wang, Jingqi
    Qian, Lei
    Yi, Jun
    ARCHIVES OF ELECTRICAL ENGINEERING, 2019, 68 (01) : 63 - 75
  • [27] MOTOR-DRIVES 1985 - DESIGNED FOR PROGRAMMABLE MOTION CONTROL IN THE FACTORY AUTOMATION ERA
    BAILEY, SJ
    CONTROL ENGINEERING, 1985, 32 (04) : 159 - 163
  • [28] Remote Control and Supervision of a Factory Automation System based on Internet of Things
    Aniba, Yehya
    Bouhedda, Mounir
    Bachene, Mourad
    Benyezza, Hamza
    Kaddour, Benyoucef
    Chablra, Abdelahani
    2022 19th IEEE International Multi-Conference on Systems, Signals and Devices, SSD 2022, 2022, : 703 - 708
  • [29] Automation Control System of Pharmaceutical Factory based on Wireless Sensor Network
    Shang, Qiu-feng
    Zhang, Lin
    ADVANCED DESIGN AND MANUFACTURING TECHNOLOGY III, PTS 1-4, 2013, 397-400 : 1271 - 1277
  • [30] Control and monitoring of factory automation system using fuzzy Petri nets
    Roh, MG
    Hong, SE
    ISIE 2001: IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS PROCEEDINGS, VOLS I-III, 2001, : 144 - 149