Ultra-low-field MRI for the detection of liquid explosives

被引:55
|
作者
Espy, M. [1 ]
Flynn, M. [1 ]
Gomez, J. [1 ]
Hanson, C. [1 ]
Kraus, R. [1 ]
Magnelind, P. [1 ]
Maskaly, K. [1 ]
Matlashov, A. [1 ]
Newman, S. [1 ]
Owens, T. [1 ]
Peters, M. [1 ]
Sandin, H. [1 ]
Savukov, I. [1 ]
Schultz, L. [1 ]
Urbaitis, A. [1 ]
Volegov, P. [1 ]
Zotev, V. [1 ]
机构
[1] Los Alamos Natl Lab, Appl Modern Phys Grp, Los Alamos, NM 87545 USA
来源
SUPERCONDUCTOR SCIENCE & TECHNOLOGY | 2010年 / 23卷 / 03期
关键词
NUCLEAR-QUADRUPOLE RESONANCE; QUANTUM INTERFERENCE DEVICE; MICROTESLA MAGNETIC-FIELDS; NMR; SPECTROMETER; RELAXOMETRY; MEG;
D O I
10.1088/0953-2048/23/3/034023
中图分类号
O59 [应用物理学];
学科分类号
摘要
Recently it has become both possible and practical to use magnetic resonance (MR) at magnetic fields in the range from mu T to mT, the so-called ultra-low-field (ULF) regime. SQUID (superconducting quantum interference device) sensor technology allows for ultra-sensitive detection while pulsed pre-polarizing fields greatly enhance the signal. The instrumentation allows for unprecedented flexibility in signal acquisition sequences and simplified MRI instrumentation. Here we present results for a new application of ULF MRI and relaxometry for the detection and characterization of liquids. We briefly describe the motivation and advantages of the ULF MR approach, and present recent results from a seven-channel ULF MRI/relaxometer system constructed to non-invasively inspect liquids at a security checkpoint for the presence of hazardous material. The instrument was deployed at the Albuquerque International Airport in December 2008, and results from that endeavor are also presented.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] High-Field-Blinded Assessment of Portable Ultra-Low-Field Brain MRI for Multiple Sclerosis
    Okar, Serhat V.
    Nair, Govind
    Kawatra, Karan D.
    Thommana, Ashley A.
    Donnay, Corinne A.
    Gaitan, Maria I.
    Stein, Joel M.
    Reich, Daniel S.
    JOURNAL OF NEUROIMAGING, 2025, 35 (01)
  • [22] Ultra-Low-Field Portable MRI and Extracorporeal Membrane Oxygenation: Preclinical Safety Testing
    Kang, Jin Kook
    Etchill, Eric
    Verdi, Kate
    Velez, Ana K.
    Kearney, Sean
    Dodd-o, Jeffrey
    Bush, Errol
    By, Samantha
    Boskamp, Eddy
    Wilcox, Christopher
    Choi, Chun Woo
    Kim, Bo Soo
    Whitman, Glenn J. R.
    Cho, Sung-Min
    CRITICAL CARE EXPLORATIONS, 2024, 6 (10)
  • [23] Investigation of Magnetic Interference Induced via Gradient Field Coils for Ultra-Low-Field MRI Systems
    Oyama, D.
    Hatta, J.
    Miyamoto, M.
    Adachi, Y.
    Higuchi, M.
    Kawai, J.
    Fujihira, J.
    Tsuyuguchi, N.
    Uehara, G.
    11TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS2013), PTS 1-4, 2014, 507
  • [24] Current-density imaging using ultra-low-field MRI with zero-field encoding
    Vesanen, Panu T.
    Nieminen, Jaakko O.
    Zevenhoven, Koos C. J.
    Hsu, Yi-Cheng
    Ilmoniemi, Risto J.
    MAGNETIC RESONANCE IMAGING, 2014, 32 (06) : 766 - 770
  • [25] Sub-millimetric ultra-low-field MRI detected in situ by a dressed atomic magnetometer
    Bevilacqua, Giuseppe
    Biancalana, Valerio
    Dancheva, Yordanka
    Vigilante, Antonio
    APPLIED PHYSICS LETTERS, 2019, 115 (17)
  • [26] Automatic Spatial Calibration of Ultra-Low-Field MRI for High-Accuracy Hybrid MEG-MRI
    Makinen, Antti J.
    Zevenhoven, Koos C. J.
    Ilmoniemi, Risto J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (06) : 1317 - 1327
  • [27] Introducing Ultra-Low-Field MRI to Radiation Therapy - Radiofrequency Breast Coil Optimization and Design
    Hornung, T.
    Koonjoo, N.
    Yan, S.
    Rosen, M.
    Bortfeld, T.
    MEDICAL PHYSICS, 2022, 49 (06) : E225 - E225
  • [28] Simulation and Optimization Study of an Ultra-Low-Field Bell-Shaped Head MRI Electromagnet
    Ye Ding
    Pan Guo
    Jiamin Wu
    Yucheng He
    Zheng Xu
    Applied Magnetic Resonance, 2021, 52 : 691 - 704
  • [29] Simulation and Optimization Study of an Ultra-Low-Field Bell-Shaped Head MRI Electromagnet
    Ding, Ye
    Guo, Pan
    Wu, Jiamin
    He, Yucheng
    Xu, Zheng
    APPLIED MAGNETIC RESONANCE, 2021, 52 (06) : 691 - 704
  • [30] Safety in Simultaneous Ultra-Low-Field MRI and MEG: Forces Exerted on Magnetizable Objects by Magnetic Fields
    Dabek, Juhani
    Sannholm, Fredrik
    Nieminen, Jaakko O.
    Vesanen, Panu T.
    Ilmoniemi, Risto J.
    17TH INTERNATIONAL CONFERENCE ON BIOMAGNETISM ADVANCES IN BIOMAGNETISM - BIOMAG2010, 2010, 28 : 74 - 77