Reporting of activated partial thromboplastin time (aPTT): Could we achieve better comparability of the results?

被引:4
|
作者
Bronic, Ana [1 ,2 ]
Margetic, Sandra [1 ,2 ]
Herak, Desiree Coen [2 ,3 ]
Milic, Marija [2 ,4 ,5 ]
Kresic, Branka [2 ,6 ]
Biljak, Vanja Radisic [2 ,7 ]
Krleza, Jasna Lenicek [8 ,9 ]
机构
[1] Sestre Milosrdnice Univ Hosp Ctr, Clin Inst Chem, Zagreb, Croatia
[2] Croatian Soc Med Biochem & Lab Med, Working Grp Lab Coagulat, Zagreb, Croatia
[3] Univ Hosp Ctr Zagreb, Dept Lab Diagnost, Zagreb, Croatia
[4] Univ Hosp Ctr Osijek, Dept Clin Lab Diagnost, Osijek, Croatia
[5] Josip Juraj Strossmayer Univ Osijek, Fac Med, Osijek, Croatia
[6] Univ Hosp Ctr Split, Dept Med Lab Diagnost, Split, Croatia
[7] Univ Hosp Sveti Duh, Dept Med Lab Diagnost, Zagreb, Croatia
[8] Childrens Hosp Zagreb, Dept Lab Diagnost, Zagreb, Croatia
[9] Croatian Ctr Qual Assessment Lab Med CROQALM, Zagreb, Croatia
关键词
activated partial thromboplastin time; external quality assessment; harmonization;
D O I
10.11613/BM.2021.020708
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: Activated partial thromboplastin time (aPTT) is determined and reported as clotting time in seconds aPTT(s), but it is presumed that reporting results as patient-to-normal clotting time ratio, aPTT(r), could minimize within-laboratory variability. The aim of study was to investigate differences in reporting aPTT results that can affect comparability of the results among Croatian laboratories and suggest further steps for its harmonization. Materials and methods: The questionnaire on aPTT reporting practice was distributed to 83 laboratories through Survey Monkey application in March 2019 as the part of the first regular round of Croatian Centre for Quality Assessment in Laboratory Medicine proficiency testing. Results: The survey response rate was 0.49. Majority of laboratories report aPTT results as both, seconds and ratio. Participants reported use of 23 different aPTT(s) reference intervals along with 17 different combinations of reagent/coagulometer and 25 aPTT(s) denominators of different origin for aPTT(r) calculation. Despite the same aPTT(s) results, the use of different denominators caused a dispersion of aPTT(r) results that can lead to exceeding external quality assessment performance criteria of 7%, particularly when results were compared for the same reagent group only. By applying aPTT(s) reference interval mean as denominator for calculation of aPTT(r) reference interval better concordance to harmonized one was obtained (17 vs. 27; chi(2) = 3.972; P = 0.046). Conclusion: In order to improve comparability of the results, laboratories are advised to use mean of aPTT(s) reference interval as denominator for aPTT(r) calculation. Type of coagulometer need to be considered when evaluating aPTT proficiency test results and its currently acceptable limit of performance evaluated accordingly.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Effects of sample storage time and temperature on prothrombin time (PT), activated partial thromboplastin time (APTT) and fibrinogen
    Rogatko, I.
    Kolczyk, A.
    Sztefko, K.
    CLINICA CHIMICA ACTA, 2019, 493 : S381 - S381
  • [32] Prolonged activated partial thromboplastin time (aPTT) during presurgical testing in 154 children.
    Rifkin, S
    Karayalcin, G
    BLOOD, 1999, 94 (10) : 236A - 236A
  • [33] Differences in the Composition of Activated Partial Thromboplastin Time (APTT) Reagents Affect Clot Waveform Analysis
    Kato, Konami
    Hatayama, Yuki
    Shimohiro, Hisashi
    Ichikawa, Hitomi
    Fukuda, Tetsuya
    YONAGO ACTA MEDICA, 2022, 65 (03) : 226 - 230
  • [34] Factor V Leiden: A reliable screening assay based on activated partial thromboplastin time (APTT)
    Vu, L
    Demers, C
    Jobin, F
    Delage, R
    Jacques, L
    THROMBOSIS AND HAEMOSTASIS, 1997, : PS83 - PS83
  • [35] Activated partial thromboplastin time
    Rodgers, GM
    LABORATORY MEDICINE, 1999, 30 (10) : 640 - 640
  • [36] Influence of factor XII deficiency on activated partial thromboplastin time (aPTT) in critically ill patients
    Mirjam Bachler
    Christian Niederwanger
    Tobias Hell
    Judith Höfer
    Dominic Gerstmeyr
    Bettina Schenk
    Benedikt Treml
    Dietmar Fries
    Journal of Thrombosis and Thrombolysis, 2019, 48 : 466 - 474
  • [37] DIFFERENCES IN THE COMPOSITION OF ACTIVATED PARTIAL THROMBOPLASTIN TIME (APTT) REAGENTS AFFECT CLOT WAVEFORM ANALYSIS
    Kato, Konami
    Hatayama, Yuki
    Shimohiro, Hisashi
    Ichikawa, Hitomi
    Fukuda, Tetsuya
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 : 81 - 82
  • [38] Evaluation of activated partial thromboplastin time (aPTT) reagents for application in biomedical diagnostic device development
    Dudek, M. M.
    Harris, L. F.
    Killard, A. J.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2011, 33 (03) : 272 - 280
  • [39] THE ACTIVATED PARTIAL THROMBOPLASTIN TIME .1. SENSITIVITY TESTING, FACTOR ASSAYS, AND THE PROLONGED APTT
    HAWTHORNE, BK
    GODWIN, J
    EMERGENCY MEDICINE, 1986, 18 (16) : 109 - &
  • [40] Influence of factor XII deficiency on activated partial thromboplastin time (aPTT) in critically ill patients
    Bachler, Mirjam
    Niederwanger, Christian
    Hell, Tobias
    Hoefer, Judith
    Gerstmeyr, Dominic
    Schenk, Bettina
    Treml, Benedikt
    Fries, Dietmar
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2019, 48 (03) : 466 - 474