Coronary sinus flow measurement by means of velocity-encoded cine MR imaging:: Validation by using flow probes in dogs

被引:40
|
作者
Lund, GK
Wendland, MF
Shimakawa, A
Arheden, H
Ståhlberg, F
Higgins, CB
Saeed, M
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Univ Lund Hosp, Dept Clin Physiol, S-22185 Lund, Sweden
[3] Univ Lund Hosp, Dept Radiat Phys, S-22185 Lund, Sweden
[4] GE Med Syst, Milwaukee, WI USA
关键词
coronary vessels; flow dynamics; MR; stenosis or obstruction; magnetic resonance (MR); cine studies; experimental studies; vascular studies; myocardium. blood supply;
D O I
10.1148/radiology.217.2.r00nv10487
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To validate coronary sinus flow measurements for quantification of global left ventricular (LV) perfusion by means of velocity-encoded cine (VEC) magnetic resonance (MR) imaging and flow probes. MATERIALS AND METHODS: Measurements of coronary sinus flow were performed in seven dogs by using VEC MR imaging at baseline, single coronary arterial stenosis, dipyridamole stress, and reactive hyperemia. These measurements were compared with flow probe measurements of coronary blood flow (CBF) in the left anterior descending coronary (LAD) and circumflex (CFX) arteries (CBFLAD+CFX) and coronary sinus. LV blood perfusion was calculated in milliliters per minute per gram from coronary sinus flow, and LV mass was obtained by using VEC and cine MR imaging. LV mass was validated at autopsy. RESULTS: CBFLAD+CFX and coronary sinus flow at VEC MR imaging showed close correlation (r = 0.98, P < .001). The difference between CBFLAD+CFX and MR coronary sinus flow was 3.1 mL/min +/- 8.5 (SD). LV mass at cine MR imaging was not significantly different from that at autopsy (73.2 g +/- 12.8 vs 69.4 g +/- 12.8). At baseline, myocardial perfusion was 0.40 mL/min/g +/- 0.09 at VEC MR imaging, and CBFLAD+CFX was 0.44 ml/min/g +/- 0.08 (not significant). Reactive hyperemia resulted in 2.7- and 2.3-fold increases in coronary sinus flow at VEC MR imaging and flow probe CBFLAD+CFX respectively. CONCLUSION: VEC MR imaging has the potential to measure coronary sinus flow during different physiologic conditions and can serve as a noninvasive modality to quantify global LV perfusion in patients.
引用
收藏
页码:487 / 493
页数:7
相关论文
共 50 条
  • [21] Coronary sinus flow reserve in response to cold pressor stress in healthy women using velocity-encoded cine (VEC) spiral 3 T MRI
    Christopher D Maroules
    Alice Y Chang
    Andrew Kontak
    Hardik Yadav
    Tommy Tillery
    Ron M Peshock
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [22] COMPARISON OF VELOCITY-ENCODED MR IMAGING AND FLUID DYNAMIC MODELING OF STEADY AND DISTURBED FLOW
    SUN, Y
    HEARSHEN, DO
    RANKIN, GW
    HAGGAR, AM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04): : 443 - 452
  • [23] Velocity-encoded cine MR imaging in aortic coarctation: Functional assessment of hemodynamic events
    Hom, Jeffrey J.
    Ordovas, Karen
    Reddy, Gautham P.
    RADIOGRAPHICS, 2008, 28 (02) : 407 - 416
  • [24] Evaluation of flow volume and flow patterns in the patent false lumen of chronic aortic dissections using velocity-encoded cine magnetic resonance imaging
    Inoue, T
    Watanabe, S
    Sakurada, H
    Ono, K
    Urano, M
    Hijikata, Y
    Saito, I
    Masuda, Y
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2000, 64 (10): : 760 - 764
  • [25] RIGHT AND LEFT-VENTRICULAR STROKE VOLUME MEASUREMENTS WITH VELOCITY-ENCODED CINE MR IMAGING - INVITRO AND INVIVO VALIDATION
    KONDO, C
    CAPUTO, GR
    SEMELKA, R
    FOSTER, E
    SHIMAKAWA, A
    HIGGINS, CB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) : 9 - 16
  • [26] RIGHT AND LEFT LUNG PERFUSION - INVITRO AND INVIVO VALIDATION WITH OBLIQUE-ANGLE, VELOCITY-ENCODED CINE MR IMAGING
    CAPUTO, GR
    KONDO, C
    MASUI, T
    GERACI, SJ
    FOSTER, E
    OSULLIVAN, MM
    HIGGINS, CB
    RADIOLOGY, 1991, 180 (03) : 693 - 698
  • [27] Flussquantifizierung in Koronar- und Bypass- gefäßen mit der MR-PhasenkontrasttechnikAssessment of flow quantification in coronary bypass grafts and coronary arteries with velocity-encoded cine MR imaging
    K.-F. Kreitner
    T. Voigtländer
    T. Wittlinger
    M. Dahm
    P. Kalden
    J. Meyer
    M. Thelen
    Der Radiologe, 2000, 40 : 143 - 149
  • [28] Pulmonary arterial resistance: Noninvasive measurement with indexes of pulmonary flow estimated at velocity-encoded MR imaging - Preliminary experience
    Mousseaux, E
    Tasu, JP
    Jolivet, O
    Simonneau, G
    Bittoun, J
    Gaux, JC
    RADIOLOGY, 1999, 212 (03) : 896 - 902
  • [29] Measurement of coronary blood flow velocity during handgrip exercise using breath-hold velocity encoded cine magnetic resonance imaging
    Globits, S
    Sakuma, H
    Shimakawa, A
    Foo, TKF
    Higgins, CB
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (02): : 234 - &
  • [30] QUANTIFICATION OF COLLATERAL BLOOD-FLOW IN COARCTATION OF THE AORTA BY VELOCITY-ENCODED CINE MAGNETIC-RESONANCE-IMAGING
    STEFFENS, JC
    BOURNE, MW
    SAKUMA, H
    OSULLIVAN, M
    HIGGINS, CB
    CIRCULATION, 1994, 90 (02) : 937 - 943