Reproducibility of Optic Nerve Head Parameters Measured With Cirrus HD-OCT in Glaucomatous Eyes

被引:0
|
作者
Chang, R. T. [1 ]
Mwanza, J. -C. [2 ]
Gendy, M. G. [2 ]
Oakley, J. D. [3 ]
Feuer, W. J. [4 ]
Budenz, D. L. [5 ]
机构
[1] Stanford Univ, Sch Med, Ophthalmol, Menlo Pk, CA USA
[2] Bascom Palmer Eye Inst, Ophthalmol, Miami, FL 33136 USA
[3] Carl Zeiss Meditec, Dublin, CA USA
[4] Bascom Palmer, Biostat, Miami, FL USA
[5] Bascom Palmer Eye Inst, Ophthal Epidemiol & Publ Hlth, Miami, FL 33136 USA
关键词
imaging methods (CT; FA; ICG; MRI; OCT; RTA; SLO; ultrasound); imaging/image analysis: clinical; optic disc;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
2751
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Prevalence and Distribution of Segmentation Errors in Macular Ganglion Cell Analysis of Healthy Eyes Using Cirrus HD-OCT
    Alshareef, Rayan A.
    Dumpala, Sunila
    Rapole, Shruthi
    Januwada, Manideepak
    Goud, Abhilash
    Peguda, Hari Kumar
    Chhablani, Jay
    PLOS ONE, 2016, 11 (05):
  • [32] Effect of pupil dilation on retinal nerve fibre layer thickness measurements and their repeatability with Cirrus HD-OCT
    G Savini
    M Carbonelli
    V Parisi
    P Barboni
    Eye, 2010, 24 : 1503 - 1508
  • [33] Cirrus HD-OCT Short-Term Repeatability of Clinical Retinal Nerve Fiber Layer Measurements
    Wong, Elizabeth
    Yoshioka, Nayuta
    Kalloniatis, Michael
    Zangerl, Barbara
    OPTOMETRY AND VISION SCIENCE, 2015, 92 (01) : 83 - 88
  • [34] Reproducibility of disc and macula optical coherence tomography using the Canon OCT-HS100 as compared with the Zeiss Cirrus HD-OCT
    Brautaset, Rune
    Birkeldh, Ulrika
    Rosen, Rebecka
    Ramsay, Marika Wahlberg
    Nilsson, Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (05) : 722 - 727
  • [35] Comparison of measurement error of Cirrus HD-OCT and Heidelberg Retina Tomograph 3 in patients with early glaucomatous visual field defect
    Alexander A. Shpak
    Maria K. Sevostyanova
    Svetlana N. Ogorodnikova
    Irina N. Shormaz
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2012, 250 : 271 - 277
  • [36] Repeatability and reproducibility of optic nerve head optical coherence tomography angiography (OCTA) measurements on glaucomatous and normal eyes
    Di, Lung
    Yu, Sophia
    Sha, Patricia
    Severin, Todd
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [37] REPRODUCIBILITY OF TOPOGRAPHIC MEASUREMENTS OF THE NORMAL AND GLAUCOMATOUS OPTIC-NERVE HEAD
    MICHAELICOHEN, A
    VERSANO, D
    NEUDORFER, M
    DZHANOV, R
    LAZAR, M
    SILVER, DM
    GEYER, O
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S975 - S975
  • [38] Comparison of measurement error of Cirrus HD-OCT and Heidelberg Retina Tomograph 3 in patients with early glaucomatous visual field defect
    Shpak, Alexander A.
    Sevostyanova, Maria K.
    Ogorodnikova, Svetlana N.
    Shormaz, Irina N.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (02) : 271 - 277
  • [39] Glaucoma Diagnostic Capabilities of Optic Nerve Head Parameters as Determined by Cirrus HD Optical Coherence Tomography
    Sung, Kyung Rim
    Na, Jung Hwa
    Lee, Youngrok
    JOURNAL OF GLAUCOMA, 2012, 21 (07) : 498 - 504
  • [40] Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes
    Budenz, Donald L.
    Fredette, Marie-Josee
    Feuer, William J.
    Anderson, Douglas R.
    OPHTHALMOLOGY, 2008, 115 (04) : 661 - 666