Stereotactic body radiation therapy (SBRT) and respiratory gating in lung cancer: dosimetric and radiobiological considerations

被引:17
|
作者
Herman, Tania De La Fuente [1 ]
Vlachaki, Maria T. [2 ]
Herman, Terence S. [1 ]
Hibbitts, Kerry [1 ]
Stoner, Julie A.
Ahmad, Salahuddin [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Dept Radiat Oncol, Oklahoma City, OK 73104 USA
[2] British Columbia Canc Agcy, Dept Radiat Oncol, Victoria, BC, Canada
来源
关键词
SBRT; 4D CT; lung cancer; radiobiological modeling; PHASE-II; RADIOTHERAPY; PNEUMONITIS; VOLUME; TUMORS; RISK;
D O I
10.1120/jacmp.v11i1.3133
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to assess the impact of respiratory gating on tumor and normal tissue dosimetry in patients treated with SBRT for early stage non-small cell lung cancer (NSCLC). Twenty patients with stage I NSCLC were studied. Treatment planning was performed using four-dimensional computed tomography (4D CT) with free breathing (Plan I), near-end inhalation (Plan II), and near-end exhalation (Plan III). The prescription dose was 60 Gy in three fractions. The tumor displacement was most pronounced for lower peripheral lesions (average 7.0 mm, range 4.1-14.3 mm) when compared to upper peripheral (average 2.4 mm, range 1.0-5.1 mm) or central lesions (average 2.9 mm, range 1.0-4.1 mm). In this study, the pencil beam convolution (PBC) algorithm with modified Batho power law for tissue heterogeneity was used for dose calculation. There were no significant differences in tumor and normal tissue dosimetry among the three gated plans. Tumor location however, significantly influenced tumor doses because of the necessity of respecting normal tissue constraints of centrally located structures. For plans I, II and III, average doses to central lesions were lower as compared with peripheral lesions by 4.88 Gy, 8.24 Gy and 6.93 Gy for minimum PTV and 0.98, 1.65 and 0.87 Gy for mean PTV dose, respectively. As a result, the mean single fraction equivalent dose (SFED) values were also lower for central compared to peripheral lesions. In addition, central lesions resulted in higher mean doses for lung, esophagus, and ipsilateral bronchus by 1.24, 1.93 and 7.75 Gy, respectively. These results indicate that the tumor location is the most important determinant of dosimetric optimization of SBRT plans. Respiratory gating proved unhelpful in the planning of these patients with severe COPD.
引用
收藏
页码:158 / 169
页数:12
相关论文
共 50 条
  • [1] Stereotactic Body Radiation Therapy (SBRT) I: Clinical and Radiobiological Considerations
    Kavanagh, B.
    Chang, E.
    Chang, Eric Lin
    MEDICAL PHYSICS, 2008, 35 (06)
  • [2] Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer
    Yang, Yun
    Catalano, Suzanne
    Kelsey, Chris R.
    Yoo, David S.
    Yin, Fang-Fang
    Cai, Jing
    MEDICAL DOSIMETRY, 2014, 39 (01) : 117 - 121
  • [3] Dosimetric Evaluation of Lung Stereotactic Body Radiation Therapy (SBRT) Treatment Plans
    Giaddui, T.
    Wang, B.
    Hollander, A.
    Micaily, B.
    Miyamoto, C.
    Li, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [4] Establishing a Stereotactic Body Radiation Therapy (SBRT) Clinical Program, Part 2: Clinical and Radiobiological Considerations
    Read, P.
    Kavanagh, B.
    MEDICAL PHYSICS, 2009, 36 (06) : 2781 - +
  • [5] Stereotactic body radiation therapy, part III: Radiobiological considerations
    Kavanagh, B
    Benedict, S
    Song, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1766 - 1766
  • [6] Repeat Thoracic Stereotactic Body Radiation Therapy (SBRT) for Nonsmall Cell Lung Cancer: Long-Term Outcomes, Toxicity, and Dosimetric Considerations
    Ricco, Anthony
    Barlow, Sara
    Feng, Jing
    Jacob, Janson
    Lozano, Alicia
    Hanlon, Alexandra
    Arrigo, Stephen
    Obayomi-Davies, Olusola
    Lamond, John
    Yang, Jun
    Lanciano, Rachelle
    ADVANCES IN RADIATION ONCOLOGY, 2020, 5 (05) : 984 - 993
  • [7] Lung Stereotactic Body Radiation Therapy: Is There a Difference in Outcome Based on Respiratory Gating?
    Schub, M.
    Dohopolski, M.
    Horne, Z. D.
    Burton, S. A.
    Christie, N.
    Jang, S.
    Heron, D. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E684 - E685
  • [8] A Dosimetric Comparison of Two Treatment Setups for Lung Stereotactic Body Radiation Therapy (SBRT) Patients
    Lewis, D.
    Wang, X.
    Gao, S.
    Nitsch, P.
    Pollard, J.
    Sadagopan, R.
    Balter, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3336 - 3336
  • [9] A review on the technical and dosimetric aspects of stereotactic body radiation therapy (SBRT)
    Saw, Cheng B.
    Bao, Shanglian
    Li, Sicong
    JOURNAL OF RADIATION ONCOLOGY, 2012, 1 (04) : 317 - 322
  • [10] Stereotactic body radiation therapy (SBRT) for lung metastases
    Okunieff, Paul
    Petersen, Anncatrine L.
    Philip, Abraham
    Milano, Michael T.
    Katz, Alan W.
    Boros, Laszlo
    Schell, Michael C.
    ACTA ONCOLOGICA, 2006, 45 (07) : 808 - 817