Portable Accelerometer-Based Navigation System for Cup Placement of Total Hip Arthroplasty: A Prospective, Randomized, Controlled Study

被引:40
|
作者
Tanino, Hiromasa [1 ]
Nishida, Yasuhiro [1 ]
Mitsutake, Ryo [1 ]
Ito, Hiroshi [1 ]
机构
[1] Asahikawa Med Univ, Dept Orthopaed Surg, Midorigaoka Higashi 2-1-1-1, Asahikawa, Hokkaido 0788510, Japan
来源
JOURNAL OF ARTHROPLASTY | 2020年 / 35卷 / 01期
关键词
navigation; randomized trial; portable; total hip arthroplasty; cup position; TOTAL KNEE ARTHROPLASTY; COMPUTER-ASSISTED NAVIGATION; ACETABULAR COMPONENT; SAFE ZONE; ACCURACY; ALIGNMENT;
D O I
10.1016/j.arth.2019.08.044
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Malposition of the acetabular component during total hip arthroplasty (THA) is associated with increased risk of dislocation, reduced range of motion, and accelerated wear. The purpose of this study is to compare cup positioning with a portable, accelerometer-based hip navigation system and conventional surgical technique. Methods: In a prospective, randomized, clinical study, cups were implanted with a portable, accelerometer-based hip navigation system (navigation group; n = 55) or conventional technique (conventional group; n = 55). THA was conducted in the lateral position and through posterior approach. The cup position was determined postoperatively on pelvic radiograph and computed tomography scans. Results: An average cup abduction of 39.2 degrees +/- 4.6 degrees (range, 27 degrees to 50 degrees) and an average cup anteversion of 14.6 degrees +/- 6.1 degrees (range, 1 degrees to 27.5 degrees) were found in the navigation group, and an average cup abduction of 42.9 degrees +/- 8.0 degrees (range, 23 degrees to 73 degrees) and an average cup anteversion of 11.6v +/- 7.7 degrees (range, -12.1 degrees to 25 degrees) in the conventional group. A smaller variation in the navigation group was indicated for cup abduction (P =.001). The deviations from the target cup position were significantly lower in the navigation group (P =.001,.016). While only 37 of 55 cups in the conventional group were inside the Lewinnek safe zone, 51 of 55 cups in the navigation group were placed inside this safe zone (P =.006). The navigation procedure took a mean of 10 minutes longer than the conventional technique. Conclusion: Use of the portable, accelerometer-based hip navigation system can improve cup positioning in THA. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:172 / 177
页数:6
相关论文
共 50 条
  • [41] Accelerometer-Based Portable Navigation System Is Useful for Tibial Bone Cutting in Modified Kinematically Aligned Total Knee Arthroplasty
    Tsubosaka, Masanori
    Kamenaga, Tomoyuki
    Kuroda, Yuichi
    Takayama, Koji
    Hashimoto, Shingo
    Ishida, Kazunati
    Hayashi, Shinya
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    JOURNAL OF KNEE SURGERY, 2021, 34 (08) : 870 - 876
  • [42] Accuracy of acetabular cup insertion in an anterolateral supine approach using an accelerometer-based portable navigation system
    Masahiro Hasegawa
    Yohei Naito
    Shine Tone
    Hiroki Wakabayashi
    Akihiro Sudo
    Journal of Artificial Organs, 2021, 24 : 82 - 89
  • [43] Accuracy of acetabular cup insertion in an anterolateral supine approach using an accelerometer-based portable navigation system
    Hasegawa, Masahiro
    Naito, Yohei
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    JOURNAL OF ARTIFICIAL ORGANS, 2021, 24 (01) : 82 - 89
  • [44] Use of an Ultrasound-Based Navigation System for an Accurate Acetabular Positioning in Total Hip Arthroplasty A Prospective, Randomized, Controlled Study
    Wassilew, Georgi I.
    Perka, Carsten
    Janz, Viktor
    Koenig, Christian
    Asbach, Patrick
    Hasart, Olaf
    JOURNAL OF ARTHROPLASTY, 2012, 27 (05): : 687 - 694
  • [45] Extramedullary Guides Versus Portable, Accelerometer-Based Navigation for Tibial Alignment in Total Knee Arthroplasty: A Randomized, Controlled Trial: Winner of the 2013 HAP PAUL Award
    Nam, Denis
    Cody, Elizabeth A.
    Nguyen, Joseph T.
    Figgie, Mark P.
    Mayman, David J.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (02): : 288 - 294
  • [46] An accelerometer-based portable navigation system improved prosthetic alignment after total knee arthroplasty in 3D measurements
    Hideki Ueyama
    Yukihide Minoda
    Ryo Sugama
    Yoichi Ohta
    Kazumasa Yamamura
    Suguru Nakamura
    Susumu Takemura
    Hiroaki Nakamura
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1580 - 1586
  • [47] The Accuracy of a Portable Accelerometer-Based Navigation System for Tibial Alignment Can be Reliable during Total Knee Arthroplasty for Obese Patients
    Goto, Kazumi
    Hirota, Jinso
    Miyamoto, Yoshinari
    Katsuragawa, Yozo
    JOURNAL OF KNEE SURGERY, 2024, 37 (04) : 303 - 309
  • [48] An accelerometer-based portable navigation system improved prosthetic alignment after total knee arthroplasty in 3D measurements
    Ueyama, Hideki
    Minoda, Yukihide
    Sugama, Ryo
    Ohta, Yoichi
    Yamamura, Kazumasa
    Nakamura, Suguru
    Takemura, Susumu
    Nakamura, Hiroaki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (05) : 1580 - 1586
  • [49] The Accuracy of Cup Placement in Total Hip Arthroplasty (THA) Using an Augmented Reality-Based Navigation System
    Shimizu, Junya
    Nagoya, Satoshi
    Kosukegawa, Ima
    Kanaizumi, Arata
    Nakahashi, Naoya
    Teramoto, Atsushi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [50] Using Accelerometer-Based Portable Navigation to Perform Accurate Total Knee Arthroplasty Bone Resection in Asian Patients
    Ueyama, Hideki
    Matsui, Yoshio
    Minoda, Yukihide
    Matsuura, Masanori
    Nakamura, Hiroaki
    ORTHOPEDICS, 2017, 40 (03) : E465 - E472