Portable Accelerometer-Based Navigation System for Cup Placement of Total Hip Arthroplasty: A Prospective, Randomized, Controlled Study

被引:39
|
作者
Tanino, Hiromasa [1 ]
Nishida, Yasuhiro [1 ]
Mitsutake, Ryo [1 ]
Ito, Hiroshi [1 ]
机构
[1] Asahikawa Med Univ, Dept Orthopaed Surg, Midorigaoka Higashi 2-1-1-1, Asahikawa, Hokkaido 0788510, Japan
来源
JOURNAL OF ARTHROPLASTY | 2020年 / 35卷 / 01期
关键词
navigation; randomized trial; portable; total hip arthroplasty; cup position; TOTAL KNEE ARTHROPLASTY; COMPUTER-ASSISTED NAVIGATION; ACETABULAR COMPONENT; SAFE ZONE; ACCURACY; ALIGNMENT;
D O I
10.1016/j.arth.2019.08.044
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Malposition of the acetabular component during total hip arthroplasty (THA) is associated with increased risk of dislocation, reduced range of motion, and accelerated wear. The purpose of this study is to compare cup positioning with a portable, accelerometer-based hip navigation system and conventional surgical technique. Methods: In a prospective, randomized, clinical study, cups were implanted with a portable, accelerometer-based hip navigation system (navigation group; n = 55) or conventional technique (conventional group; n = 55). THA was conducted in the lateral position and through posterior approach. The cup position was determined postoperatively on pelvic radiograph and computed tomography scans. Results: An average cup abduction of 39.2 degrees +/- 4.6 degrees (range, 27 degrees to 50 degrees) and an average cup anteversion of 14.6 degrees +/- 6.1 degrees (range, 1 degrees to 27.5 degrees) were found in the navigation group, and an average cup abduction of 42.9 degrees +/- 8.0 degrees (range, 23 degrees to 73 degrees) and an average cup anteversion of 11.6v +/- 7.7 degrees (range, -12.1 degrees to 25 degrees) in the conventional group. A smaller variation in the navigation group was indicated for cup abduction (P =.001). The deviations from the target cup position were significantly lower in the navigation group (P =.001,.016). While only 37 of 55 cups in the conventional group were inside the Lewinnek safe zone, 51 of 55 cups in the navigation group were placed inside this safe zone (P =.006). The navigation procedure took a mean of 10 minutes longer than the conventional technique. Conclusion: Use of the portable, accelerometer-based hip navigation system can improve cup positioning in THA. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:172 / 177
页数:6
相关论文
共 50 条
  • [1] Accuracy of a portable accelerometer-based navigation system for cup placement and intraoperative leg length measurement in total hip arthroplasty: a cross-sectional study
    Hiromasa Tanino
    Yasuhiro Nishida
    Ryo Mitsutake
    Hiroshi Ito
    BMC Musculoskeletal Disorders, 22
  • [2] Accuracy of a portable accelerometer-based navigation system for cup placement and intraoperative leg length measurement in total hip arthroplasty: a cross-sectional study
    Tanino, Hiromasa
    Nishida, Yasuhiro
    Mitsutake, Ryo
    Ito, Hiroshi
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [3] Accuracy of cup orientation and learning curve of the accelerometer-based portable navigation system for total hip arthroplasty in the supine position
    Kamenaga, Tomoyuki
    Hayashi, Shinya
    Hashimoto, Shingo
    Matsumoto, Tomoyuki
    Takayama, Koji
    Fujishiro, Takaaki
    Hiranaka, Takafumi
    Niikura, Takahiro
    Kuroda, Ryosuke
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)
  • [4] Comparing the accuracy of three-dimensional mini-optical portable navigation and accelerometer-based portable navigation system for acetabular cup placement during total hip arthroplasty
    Hayashi, Shinya
    Kuroda, Yuichi
    Nakano, Naoki
    Matsumoto, Tomoyuki
    Kamenaga, Tomoyuki
    Maeda, Toshihisa
    Kuroda, Ryosuke
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) : 3759 - 3766
  • [5] Comparing the accuracy of three-dimensional mini-optical portable navigation and accelerometer-based portable navigation system for acetabular cup placement during total hip arthroplasty
    Shinya Hayashi
    Yuichi Kuroda
    Naoki Nakano
    Tomoyuki Matsumoto
    Tomoyuki Kamenaga
    Toshihisa Maeda
    Ryosuke Kuroda
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3759 - 3766
  • [6] Usefulness of an Accelerometer-Based Portable Navigation System for Total Knee Arthroplasty
    Minoda, Yukihide
    Hayakawa, Kazue
    Hagio, Keisuke
    Konishi, Natsuo
    Tamaki, Tatsuya
    Iwakiri, Kentaro
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2020, 102 (22): : 1993 - 2000
  • [7] Usefulness of an accelerometer-based portable navigation system in total knee arthroplasty
    Ikawa, T.
    Takemura, S.
    Kim, M.
    Takaoka, K.
    Minoda, Y.
    Kadoya, Y.
    BONE & JOINT JOURNAL, 2017, 99B (08): : 1047 - 1052
  • [8] A new accelerometer-based portable navigation system provides high accuracy of acetabular cup placement in total hip arthroplasty in both the lateral decubitus and supine positions
    Ohyama, Yohei
    Sugama, Ryo
    Kim, Yuha
    Ohta, Yoichi
    Minoda, Yukihide
    Nakamura, Hiroaki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) : 4473 - 4480
  • [9] A new accelerometer-based portable navigation system provides high accuracy of acetabular cup placement in total hip arthroplasty in both the lateral decubitus and supine positions
    Yohei Ohyama
    Ryo Sugama
    Yuha Kim
    Yoichi Ohta
    Yukihide Minoda
    Hiroaki Nakamura
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 4473 - 4480
  • [10] Does accelerometer-based portable navigation provide more accurate and precise cup orientation without prosthetic impingement than conventional total hip arthroplasty? A randomized controlled study
    Kiyohara, Masato
    Hamai, Satoshi
    Shiomoto, Kyohei
    Harada, Satoru
    Harada, Tetsunari
    Motomura, Goro
    Ikemura, Satoshi
    Fujii, Masanori
    Kawahara, Shinya
    Nakashima, Yasuharu
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (06) : 1007 - 1015